Solar Pumps Inverter with MPPT for 3 Phase AC Pumps. Solar pumps inverter model. Solar pump inverter Quick guide Solar arrays selection, Voc and Power selection —— Voc and power of solar arrays selection. s 5 1, The power of solar arrays should Se great 1.3 times of rated power of pumps. as Us t —7 tf 2, The Voc need large 1.15 times of Vmp. Voc=1.15*Vmp (155, 310,537,650VDC) weeeee Best Voc [ a. 178VDC for 110VAC pumps. of solar b. 355VDC for 220VAC pumps ? e arrays «©: 620VDC for 380VAC pumps. om more cop in series eT get more selecting _ % 745VDC for 460VAC pumps. Power in parallel connection Solar pumps selection, Rated power of inverter should 2 rated power of 3 phase AC pumps 4. For 3 phase AC pumps, 110VAC, 220VAC, 380VC, 460VAC. 4S model for 110VAC pumps. Need Vmp155VDC, Voc178VDC INPUT 2S model for 220VAC pumps, Need Vmp 311VDC, Voc357VDC INPUT 4T model for 380VAC pumps, Need Vmp 540VDC, Voc620VDC INPUT 2. For AC permanent magnet synchronous motor (PMSM) high efficiency pumps. 0.75kw to 7.5kw Connecting to R &T from solar panels 3 phase AC pumps 1. Connect DC power Supply to R and T Terminals without polarity distinguish 2. 3 phase AC pumps connect U, V ,W terminals. “PS: if connect DC power to care of positive and negative. P Above 15kw, there are have + and — terminals. a 3 phase Option: Onan Connectio cums nofsolar | OC power Arrays to: from Solar arrays eat ate ann ole ae Ven ar Parameters setting: ‘The SG series solar pump inverter have programmed Fa, Fb, Fc 3 groups parameters for solar pump control purpose. drive will detect Voc automatically when FC0O=0) Tf outupt freq. is 0.5Hz, please set FCO1=actual Voc from solar panels (S40V to 640VDC) , or set FCOO=0, and switch on again. Solar arrays se lection Total power and Voc selecting WIRING DC grid connect to R and T; Pumps connect U,V,W_ ‘Switch on ‘Switch on power to system after good wiring and wait 5s for initiation Pumps group parameters setting and Voc set by manual F2-01 to F2-05 motor voltage, current, frequency, poles setting as nameplate and set FC01 Voc value Voc620VDC for 4T(vmp4a6to 7S0VDC) Voc 350VDC for 28 (vmp 280 to 375VDC) DC power connect toR, T terminals Wait 20s after switch ‘on to continue next process 1.Recommend to set motors group parameters to get Better pumps protection. 2. FCO0=1 ( voc set by manual ) FC01=Voc ( set as your total Voc) Press RUN to trail run Inverter start/stop by keypad in default setting Pumps running direction confirm f the output frequency is rising but water come out is small, check the direction Auxiliary function setting sleep mode, dry run, flow PQ curve, ect setting see Fb group Automatically running setting Set Fa-01=1( terminals control ) and check X1 and GND if short circuit wiring (the If want to start/stop automatically, please set f002=1. Changed running direction if need, Change U.W, V phase order to get reverse. Fb-03, Lowest frequency Fb-06, dry run function Flow day, energy generated setting, see FB groups parameters Inverter will start At morning and stop In evening under Terminals control mode Solar Pumps Inverter with MPPT for 3 Phase AC Pumps. listed some common use parameters for review code Name Descrtion Default sting Or variable speed conto for general aon | S9larpump drive contrel 1:€VT (constant voltage contra) 2 2: MPPT (maximum power point tracking) O: Manual Coperaton pane) rao Auto/mana eases Gains cartel ° 2: Rates communiation 0; General purpore for constant argue fan Models selection 1:_ variable torque for fans and pumps. ° 0: Control panel (keypad) , Fo.02 | Running control mode selection 1: Betermal terminal (for automate tt) ° RSA85 ports FOR | Acceleration ine 1 of MPPT 0.376000 : FOA3 | Deceleration time 1 of MPPT 013-6000 05 > 8: No operation, roar Factory restore s1facory sting inialzton, ° ‘alfauts recor F405 Stop mode 0: deceleration to stop. 1 fee stop Feo Vor detect mode auto detected by itself 1: Voc set by manval by user ° Feot | Vocseting value by manual 1000 20 Fe-O2 | Deceleration time 2 ( power off ) 0.1~6000.0s _{ use to soft stop when Fa-05=0) / reat Motor ted voltage ‘+700 1 F202 Motor rated frequency 5.00~600.00Hz_ 0.01 203 Motor ated current 01-5000.08, on If you want to read more parameters of solar pump control please see Fa, Fb, FC para. of manual.

You might also like