Drying Oven KH-30A(S)/35A(S)/45A(S) (Digital Display ) Ths Deg hn Ovon Manual 1. Application scope This drying oven is widely applied to biochemistry, biopharmaceutical, medical institutions, mining industrial. schools, research institutes, for drying. curing, wax-melting, sterilization. 2. Working Principle and Structure There are heaters in the working chamber and forced air convection device at the back. Temperature controller maintains and controls temperature. When oven is working, air goes through heater and be circulated by the fan, which ensures temperature uniformity. With features of arc comer design. adjustable shelf distance, built-in temperature sensor. There is fiberglass serves as insulation between working chamber and extemal shell. The shell is made of steel plate with spraying-finished surface. Interior chamber is made of galvanized iron or stainless steel plate, with built-in pre-heating chamber and air duct. Double tempered-glass observation windows. There is heat-resistant silicone door seal between working chamber and external door, which enhances tightness and leakproofness meanwhile enhances the heat insulation. This drying oven adopts intelligent temperature control system. It has features of timer and high temperature accuracy. 3. Operation Instruction Before connecting with electricity, please make sure switch is on “OFF”. Check if there is . open-circuit or electric leakage. Get through with power and tum on power switch. 4, Controller Instruction PV Cc SV H/M (ye) eh 6) RuvAT LUT HAL OeO® Set SHE/AT Dee/Ret Ine N A. Control Panel: er? pe WfOY ke ttfen (1). “RUN/AT”: Matt on when equipment is working ight off when working finishes. Light flashes during self-adjust timing, 0 er 8G (2). SOUT": Lights on when there is heating output, ifnot then lights off. pc bP (3). “ALM Lights on when sensor goes wrong or overheat alarm alerts (4). SSW": Invalid indicator for use in case Bear (5). “SL”: Setting key(please refer to “B. Controller Operation” ) (6) . “<4”: Shift key. Under setting status, press this key to shift set nar ech. DH - value ).“¥": D Key. Under setting status, press this key to progressively decrease value. Long press to continuously decrease value. ‘ Dare g i (8). “A”: Increase key.’ Under setting status, press this key to progressively increase value, Long press to continuously increase value. B. Controller Operation: =~ (a). sho ontroller gets power on, showing “Graduation No.” and “Version No.” on upper display; ing“ «sek Valle ale” on down display. After 3 seconds, it enters to regular interface (Q). View and Set of Temperature and Temperature Timing: Without constant temperature timing function: WaerpoT A Pe Meeprar spe to enter temperature setting, It shows “SP” on down display and shows “set oc ee eo on upper display (Unit digit flashes first). Press << ¥ Ato set needed value. Press Se] heckeg ob Fo hike ; Tel ivede Modined valuormall ps Ree ay ree Under setting status, if there is no operation for 1 minute, controller will return to regular interface. Pres temperature’ ap b, With constant temperature timing function: Press © to enter temperature setting. It shows “SP” on down display and shows “set temperature’ on upper display(Unit digit flashes first), Same way as above to adjust value. Press ®t to enter temperature timing setting, It shows“ST”on down display and shows temperature timing set value * fake 1o exit. Set value will be automatically saved. on upper display(Unit digit flashes first). Press When constant temperature timing is set to be“0”, which means no timing function. Controller continuously runs and it shows set temperature value on down display. When temperature timing is not set to be “0”, it shows running time or set temperature value on down display (please refer to “Inner Parameter-2”-“ndt-"-“Timer Setting™).When it shows running time, decimal point on down display lights on. After set temperature is met, timer starts counting ee decimal point on down display flashes. When time is up, it stops running and shows “End” on down display meanwhile buzzer beeps for 1 minute and stops later, After running stops, long press ¥ for 3 seconds to resume, Notice: Increasing temperature while timer is working , timer will restart to count from oes ‘will not affect the timer if it is to reduce temperature. (3), Abnormity Alarm of Temperature Sensor If it shows “---* on upper display, which means temperature sensor or controller fail, or temperature exceeds detection range. Controller automatically cuts off heat output. Buzzer beeps. Alarm lights on. Please check the temperature sensor and its wire connection carefully. (4) For alarm triggered by upper deviation, buzzer beeps and alarm lights on. “ALM” indicator stays light on. For alarm triggered by down deviation, buzzer beeps and alarm lights flashes. If over temperature alarm is triggered due to the change of temperature setting, alarm lights on but buzzer does not beep. (5). Press and key to stop beeping. (6. If there is no operation under setting status within minute, press any key to return to regular interface, C. System Self-Adjustment: User can run self-adjustment function when the performance of temperature control is not satisfactory. Overshoot may happen during self-adjustment. User should carefully consider this fact before conducting self-adjustment. Under non-setting status, long press < (or “AT”) for 6 seconds to enter self-adjustment setting Self-adjustment indicator flashes and stops after adjustment finishes. Controller will get better PID data and these data will automatically saved. When adjustment is proceeding, long press < for 6 seconds it to discontinue. During the proceeding of self-adjustment, if there is over temperature alarm of upper deviation , » “ALM?” indicator and buzzer will not react but heater relay will be automatically cut off. During the whole process of self-adjustment, will be invalid. No matter whether there is constant temperature timing setting during the process of self-adjustment, it always shows set temperature value on down display. D. View and Setting of Temperature Inner Parameter Long press * for about 3 seconds, it shows indication code “Le” on down display and shows —_ hepor . “Password” on upper display, press 4 ¥ A to adjust to needed password. Press # —_, if password is incorrect then it will returns to regular interface; if password is correct, it enters temperature inner & & parameter setting. Press ** to adjust all parameters. Long press %t for 3 seconds to exit this setting, Set parameter will be automatically saved, Tae Le | Instruction of Parameter (Range) Factory Default Value | Pianeta View and modify parameter when it shows | | “T3" a es cee ed ee | | | | Over | } Temperature | When “Detected Temperature >Set | 100.0) ALH- lam of | Temperature + HAL”, alarm lights on and | 20.0 | ipper buzzer beeps. Heat output cuts off. | For CuSO sensor: | | Deviation (0~100.0°C) | 5.0 | Over | { | = When “Detected Temperature “0-9 0: Alarm triggered for upper deviation only naa- | Temperature | 1 “star triggered for both upper&down| (0~1) 0 Alarm ; deviation, 0: No timer function 1: With timer function, When it reaches set temperature (and begins to stay at constant ndt- | Timer Setting | temperature), it shows running time on down | (0~2) 1 display With timer function, it shows running time on down display Constant Hn- | Temperature | 0: Count by minute ; 1: Count by hour @~1)0 Timing Should cco 0: Cut off heat output after timing finishes EH- ae MT | 1; Constant temperature control continues! — (0~1) 0 | after timing finishes continues after timing is over [0 Disable the function of door open a Door Control | judgment Pn- ~1)0 oa Function |1: Enable the function of door open| ~!)° ie judgment pe || REED | Reerowereee 6 aia peat ‘age of maximum heating power output | (0~100%) 100 | a Cut off For Ptl00 Deviation of sensor: (0~ Co- Heating [Cit off heat output when “detected | 100,0'0) 50.0 Output | temperature2set temperature + Co Ree CisO asc not available For model Minimum PCD-C3000,-50 SPL- Ter it 7 i eating | Minimum set temperature 0~0.0) pane: For other model: (0.0~0.0)0.0 —e | OO ee For Pt100 sensor: (0) SPH- mperature af | | 400.0) 300.0 Setting SiniUm set temperature For Cu50 sensor (0-1000) | Addr | COM*SPondenc | Correspondence address of this equipment a e Address Refer to Notice 3 Product Drawing Control / 6. Wire Layout KH-PCD-E3000 (KH-30/35/45) sensor + Fu 7. Notice i Dn Samples should not be kept too closed to each other in order to avoid affecting air convection inside the chamber. Please make sure the equipment is correctly grounded so as to ensure safety. Do not get water onto the observation windows when temperature is rising in order to avoid glass crack, This drying oven is not explosion-proof product. Do not put volatile and inflammable objects into the oven to avoid explosion Based on different needs, user can unblock the air outlet at the upper back of the oven to escalate drying. 8, Repair and Maintenance a, Regular Maintenance i always Keepsthe equipment clean, Window gto s should be cleaned with soft cotton fabric but should not be cleaned with corrosive chem! cal solvent to avoid chemical reaction or gla: Scratch, If the equipment is not being ed for a long time, it should smear neutral oil or Vaseline onto gi wanized parts to prevent corrosion, Cover the equipment with plastic dust cover Keep Cunder a dry indoor environment to avoid moist Q\ Regular Repair: If you operate according to our manual and breakdown happens, please follow below steps for trouble shooting. If problem cannot be solved, please contact our after-sales department. We will offer you help. c. Breakdown, Analysis and Solution Breakdown ‘or power supply failure, Please seek assistance from electrician | + For case of heater burn out, pleas use multimeter with “Ohm” unit to test the resistance value of heater’s two ends. If | 1, No response after | resistance value is 0-which means short-circuit happens to | heating wires. In th value is hundre happens | * Power switch blade is off | | | ‘witch could trip often. If resistance KOhm or infinity which means open circuit | connecting to power and tum on power switch Power switch lights on, check the control circuit board and cables ie | & Cheek if timing met set value. Many customers do not | | know about this function, When set timing is over then heater and fan will stop worki | 2. Temperature fails to rise | * Check if | | replacement. | + Use a multimeter to check if there is output from the control | panel. Please check it according to the drawing; (Drawings _{ attached). 2 so that temperature cannot rise an can work, if not, please contact us to m 1 you 3. Fan fail to work ¥* The result will be that heating can function but no circulation inside the interior chamber so that temperature rises slowly. Please contact us to replace the fan. 4. Broken Handle ¥ Contact our company to replace the handle. 5 Differential between the temperature showing on controller display and the one showing on mercurial thermometer which is put, inside the chamber Precondition of troubleshooting: “ The thermometer should be qualified by testing department before being used. +k Where to put the thermometer: Please hang the thermometer in air inside the chamber’s center. Thermometer should not be put on the shelf to detect temperature. “ Please refer to above attached parameter instruction. 6, ‘Temperature display fluctuates or stills. Or it shows abnormality like “— ¥ It identifies that there is something wrong about the temperature sensor, Our company will have it replaced. Remark: Sensor is with Pt100 platinum resistance, with 2 blue wires and 1 red wire. 9, Accessories fee 2, 2 shelves 10, Specifications Warranty card, manual, quality certificate Interior Chamber Overall Model : ooo Dimension Dimension Meee Ee Temperature | Temperature cy) | 6KW) | Rangete Fluctuation’C | H|W/D|H|w{|D | | KH-30 | 300 | 250 | 200 | 470 | 540 | 50S 0.5 | | KH-35 | 350 | 350 | 350 | 530] 640 550] 220 1.2 | +5~250 +1% KH-45 | 450 | 450 | 350 | 630 | 740 | 550 14 | 0

You might also like