Foxboro™ SCADA

RTU Station
Release Notes

*B0780SB* *N*

B0780SB, Rev N
May 2020

https://www.se.com
Legal Information
The Schneider Electric brand and any trademarks of Schneider Electric SE and its
subsidiaries referred to in this guide are the property of Schneider Electric SE or its
subsidiaries. All other brands may be trademarks of their respective owners.
This guide and its content are protected under applicable copyright laws and furnished
for informational use only. No part of this guide may be reproduced or transmitted in
any form or by any means (electronic, mechanical, photocopying, recording, or
otherwise), for any purpose, without the prior written permission of Schneider Electric.
Schneider Electric does not grant any right or license for commercial use of the guide
or its content, except for a non-exclusive and personal license to consult it on an "as is"
basis. Schneider Electric products and equipment should be installed, operated,
serviced, and maintained only by qualified personnel.
As standards, specifications, and designs change from time to time, information
contained in this guide may be subject to change without notice.
To the extent permitted by applicable law, no responsibility or liability is assumed by
Schneider Electric and its subsidiaries for any errors or omissions in the informational
content of this material or consequences arising out of or resulting from the use of the
information contained herein.
RTU Station Release Notes

Table of Contents
Preface ...............................................................................................................5
Revision Information.........................................................................................5
Related Documents..........................................................................................5
Global Customer Support .................................................................................6
We Welcome Your Comments...........................................................................6
Chapter 1: Functionality and Compatibility ...................................................7
RTU Software ..................................................................................................7
SALL Support Files ..........................................................................................9
Superseded Versions .....................................................................................10
Chapter 2: Changes Since Previous Release ............................................ 11
Defects Corrected .......................................................................................... 11
Chapter 3: Known Problems and Limitations .............................................14
Chapter 4: Validation and Verification Statement ......................................17

B0780SB, Rev N 3
n k
Bla
ef t
y L
all
io n
n t
Inte
ge
P a
h i s
T
Preface RTU Station Release Notes

Preface
This document accompanies a major release of the EcoStruxure™ Foxboro SCADA
RTU Station software, identified as part number SY-1101211_K (built from internal
baseline 17.0.0). The Foxboro RTU Station is used for configuring Foxboro remote
devices and the RTU50. This document describes:
• Changes since the previous release of this software
• Outstanding problems detected and known limitations
• Procedures for installing and upgrading the software
• Activities conducted to verify that the product is ready for release
NOTE: Read this entire document before attempting to install or use the Foxboro
RTU Station. Also, read the Release Notes for the intermediate releases before
you upgrade from an earlier release.
This document lists the changes made in the Foxboro RTU Station software since the
previous release, SY-1101211, Revision G. You can create a desktop shortcut to
these release notes by installing them on your system.
There are known problems and limitations that remain at the time of product release.
For more information, see Chapter 3: Known Problems and Limitations, page 14. In
this revision, we corrected incidents that would reduce risks to projects worldwide. For
a more detailed assessment of the advantages and disadvantages of adopting SY-
1101211_K for specific projects, visit Global Customer Support at https://pasupport.
schneider-electric.com (registration required).

Revision Information
This revision of the document includes these changes:

Global • Updated version information for Foxboro RTU Station


Software
Preface • Updated Preface, page 5
Chapter 1: • Updated Chapter 1: Functionality and Compatibility,
Functionality and page 7
Compatibility
Chapter 2: Changes • Updated Defects Corrected, page 11
Since Previous
Release
Chapter 3: Known • Updated Chapter 3: Known Problems and Limitations,
Problems and page 14
Limitations
Chapter 4: • Updated Chapter 4: Validation and Verification
Validations and Statement, page 17
Verification
Statement

Related Documents
For further information on installing, configuring, programming, and diagnosing
Foxboro remote devices and the RTU50, see the documents available on the Foxboro
RTU Product Documentation CD (Part Number: SY-2005654, Revision AA). You can
also see EcoStruxure™ Foxboro SCADA SCD6000 User Documentation CD Release
Notes (B0780SA) for a list of reference documents and their latest versions.

B0780SB, Rev N 5
RTU Station Release Notes Preface

The following list of documents have been updated for the current release:
• EcoStruxure™ Foxboro SCADA SCD6000 Hardware Programming Guide.
(B0780FB)
• EcoStruxure™ Foxboro SCADA RTU Station (SCD6000, SCD5200, RTU50/SVX)
User's Guide (B0780DQ)
• EcoStruxure™ Foxboro SCADA Remote Terminal Viewer (SCD6000, SCD5200,
RTU50/SVX) User's Guide (B0780DY)
• EcoStruxure™ Foxboro SCADA IEC 60870-5-104 Master (SCD6000, SCD5200,
RTU50/SVX) User’s Guide (B0780FC)
• EcoStruxure™ Foxboro SCADA IEC 60870-5-104 Slave (SCD6000, SCD5200,
RTU50/SVX) User’s Guide (B0780DT)
• EcoStruxure™ Foxboro SCADA IEC 60870-5-101 Master (SCD6000, SCD5200,
RTU50/SVX) User’s Guide (B0780EE)
• EcoStruxure™ Foxboro SCADA V.28 Dual Communication Board (SCD6000,
SCD5200, RTU50/SVX) User’s Guide (B0780EN)
• EcoStruxure™ Foxboro SCADA IEC 60870-5-101 Slave (SCD6000, SCD5200,
RTU50/SVX) User’s Guide (B0780EH)
• EcoStruxure™ Foxboro SCADA Intrinsic Database Functions (SCD6000,
SCD5200, RTU50/SVX) User’s Guide (B0780DR)
• EcoStruxure™ Foxboro SCADA DNP3 Slave (SCD6000, SCD5200, RTU50/SVX)
User’s Guide (B0780DC)
• EcoStruxure™ Foxboro SCADA Conitel Slave (SCD6000, SCD5200, RTU50/
SVX) User’s Guide (B0780EL)
• EcoStruxure™ Foxboro SCADA Modbus Slave (SCD6000, SCD5200, RTU50/
SVX) User’s Guide (B0780DG)
• EcoStruxure™ Foxboro SCADA RTU50/SCD5200 to SCD6000 Migration Guide
(B0780FA)
• EcoStruxure™ Foxboro SCADA SCD6000 Installation Guide (B0780EV)
• EcoStruxure™ Foxboro SCADA SCD6000 User Documentation CD Release
Notes (B0780SA)
• EcoStruxure™ Foxboro SCADA Connect Secure Release Notes (B0780SC)
• EcoStruxure™ Foxboro SCADA RTV Release Notes (B0780SD)
• EcoStruxure™ Foxboro SCADA SCD6000 Software Release Notes (B0780SF)
• EcoStruxure™ Foxboro SCADA Foxboro RTU Station CD Read Me First Release
Notes (B0799AX)

Global Customer Support


For support, visit https://pasupport.schneider-electric.com (registration required).

We Welcome Your Comments


We want to know about any corrections, clarifications, or further information you would
find useful. Send us an email at systemstechpubs@se.com.

6 B0780SB, Rev N
Chapter 1: Functionality and Compatibility RTU Station Release Notes

Chapter 1: Functionality and Compatibility


This chapter provides information on the functionality and compatibility of the
software. The Foxboro RTU Station software is installed using a graphical Microsoft
Windows ® installation program. The installation program and the Foxboro RTU
Station are supported by Windows ®10 (64-bit) and Windows ® Server 2016 (64-bit)
Operating Systems.

RTU Software
This version of the Foxboro RTU Station supports:
• Foxboro SCD5200 and RTU50 Software versions (includes utilities) (SY-
1101155-K and later)
• Foxboro SCD6000 Software versions (includes utilities) (SY-1101207_A and
later)
• Foxboro RTU50 SVX Software versions (SY-1101207_C1 and earlier)
The table, “Features Supported by the Foxboro RTU Station”, lists the subsystems
supported by the Foxboro RTU Station for the Foxboro remote devices. For
information on the part numbers of these subsystems, refer to Appendix A, Summary
of Part Numbers in EcoStruxure™ Foxboro SCD6000 Hardware User’s Guide
(B0780DW).

Table 1 - Features Supported by the Foxboro RTU Station

Subsystem For SCD6000 For RTU50 SVX For SCD5200 For RTU50
Input/Output
AC Transducer Card Yes Yes Yes Yes
Type 2
Analog Output Card Yes Yes Yes Yes
32DI/4AI Card (ADI) Yes Yes Yes Yes
- Non-Isolated
32DI/4AI Card (ADI) Yes Yes Yes Yes
- Isolated
12 Digital Output Yes Yes Yes Yes
Card (12DO) (a)
20 Analog Input Yes Yes Yes Yes
Card (20AI) - Non-
Isolated
20 Analog Input Yes Yes Yes Yes
Card (20AI) -
Isolated
Multi I/O Card Yes Yes Yes Yes
Communications
8 Channel Serial Yes Yes Yes Yes
Card
12 Channel Serial Yes Yes Yes Yes
Card (b)
Conitel Master/Slave Yes Yes Yes Yes

B0780SB, Rev N 7
RTU Station Release Notes Chapter 1: Functionality and Compatibility

Table 1 - Features Supported by the Foxboro RTU Station (Continued)

Subsystem For SCD6000 For RTU50 SVX For SCD5200 For RTU50
Input/Output
C300/C3000 Conitel No No Yes Yes
Slave
DNP3 Master Yes Yes Yes Yes (c)
DNP3 Slave Yes Yes Yes Yes (c)
IEC 60870-5-101 Yes Yes Yes Yes
Master
IEC 60870-5-101 Yes Yes Yes Yes
Slave
IEC 60870-5-103 Yes Yes Yes Yes
Master
IEC 60870-5-104 Yes No No No
Master
IEC 60870-5-104 Yes Yes Yes Yes
Slave
IEC 61850 Client/ Yes Yes Yes Yes
GOOSE Subscriber
IEC 61850 Server/ Yes Yes Yes Yes
GOOSE Publisher
Modbus Master Yes Yes Yes Yes
Modbus Slave (d) Yes Yes Yes Yes
OptoNet Yes Yes Yes Yes
TCP/IP Yes Yes Yes Yes
WISP+ Master No No Yes Yes
WISP+ Slave No No Yes Yes
Calculations
Intrinsic Database Yes Yes Yes Yes
Functions
SALL calculations Yes Yes Yes Yes
(including floating
point and gas
calculations)
IEC 61131-3 No No Yes Yes
(ISaGRAF) (e)
Expansion Bus Yes Yes No Yes
Miscellaneous
Control Interlock Yes Yes Yes Yes
Serial Event Logger Yes Yes Yes Yes
(type 2)
Terminal Server Yes Yes Yes Yes
Diagnostic Router Yes Yes Yes Yes
Diagnostic Server Yes Yes Yes Yes

8 B0780SB, Rev N
Chapter 1: Functionality and Compatibility RTU Station Release Notes

Table 1 - Features Supported by the Foxboro RTU Station (Continued)

Subsystem For SCD6000 For RTU50 SVX For SCD5200 For RTU50
Input/Output
Analog Logger and Yes Yes Yes Yes
Event logger
SALL HLSI Yes Yes Yes Yes
SNTP Protocol Yes Yes Yes Yes
Zone SEL Yes No No No
Protocol List Yes No No No
Mapping
(a) The 8 Digital Output Card is configured as 12 DO card with relays 9-12 left unconfigured.
(b)
The 12 Channel Serial card is supported only in RTU50. However, the 12 Channel Serial card can be configured
and used in SCD5200, SCD6000, and RTU50 SVX as an 8 Channel Serial card. Channels 9 to 12 cannot be
configured.
(c) Only the SCD6000 supports the DNP3 SAv2 and SAv5 Secure Authentication feature.
(d)
Modbus Slave is only supported on serial communication for all RTU models listed in the table. However,
Modbus TCP Slave is supported for SCD6000 only.
(e)
ISaGRAF is not supported on Windows 7 (64-bit) or later versions of operating system. ISaGRAF Workbench
V3.xx (3.32 or higher, but lower than 4.00) supports RTU50 and SCD5200 running on Windows XP machine.
SCD6000 and RTU50 SVX do not support ISaGRAF.

NOTE: The new modules (Expansion Bus, Zone SEL, and Protocol List Mapping)
will be supported from RTU station version _E or later for SCD6000 with the
firmware version_F or later.

Table 2 - New Components included from SY-1101211_K release onwards

Utility Name Description Installation Directory


SCL File Converter.exe SCL File Converter Utility comments C:\Program Files (x86)\Foxboro
the private data in the IEC61850 \RTU Station\utils
SCL file.

SALL Support Files


The SALL support files are needed to correctly generate SALL application binary files
for execution on an RTU. The SALL support files consist of the batch file buildsal.
bat that drives the SALL compilation process and several other files used during the
compilation process. These files are installed as part of the Foxboro RTU Station
installation. No further action is needed. For detailed instructions on compiling SALL
applications, see these documents:
• EcoStruxure™ Foxboro SCADA RTU Programming User’s Guide: State And
Logic Language Reference (B0780DK)
• EcoStruxure™ Foxboro SCADA SALL Floating Point User’s Guide (B0780DL)
Compiling SALL for SCD5200 and RTU50
To compile SALL calculations for SCD5200 or RTU50, install one of these compilers
on your workstation:
• Watcom C/C++ version 11.0a
• Watcom C/C++ version 11.0c

B0780SB, Rev N 9
RTU Station Release Notes Chapter 1: Functionality and Compatibility

• OpenWatcom C/C++ version 1.0


• OpenWatcom C/C++ version 1.1
The OpenWatcom compiler is available for free download from ftp.openwatcom.
org/archive/.
You can download one of these files:
• open-watcom-win32-1.0.exe 61 MB Jan 28 2003
• open-watcom-win32-1.1.exe 62 MB Aug 12 2003
Compiling SALL for SCD6000 and RTU50 SVX
To compile SALL calculations for the SCD6000 and RTU50 SVX modules, you need
to install the SALL Compiler for SCD6000 and RTU50 SVX on your workstation. The
SALL Compiler for SCD6000 and RTU50 SVX is available in BuyAutomation both as
a node locked version and a float license version.
The SALL Compiler can be installed on Windows ® 10 (64-bit) and Windows ® Server
2016 (64-bit), but is not officially released for these operating systems.Order the SALL
Compiler from BuyAutomation using the part numbers in this table.

Part Number Description

SY-1101214 SCD6000/RTU50-SVX SALL Compiler Node License

SY-1101215 SCD6000/RTU50-SVX SALL Compiler Float License

You can also buy support for the SALL Compiler using the part numbers in this table.

Part Number Description

SY-1101216 SCD6000/RTU50-SVX SALL Compiler Node Locked License Support

SY-1101217 SCD6000/RTU50-SVX SALL Compiler Float License Support

Superseded Versions
The SY-1101211_K release supersedes these versions of the Foxboro RTU Station
software:
• SY-1101191 (all versions up to revision M, including maintenance releases)
• SY-1101211 (all versions up to revision G, including maintenance releases G13)

10 B0780SB, Rev N
Chapter 2: Changes Since Previous Release RTU Station Release Notes

Chapter 2: Changes Since Previous Release


Defects Corrected
This release resolves change requests that were raised as a result of verification and
validation processes, both externally by customers and internally. This table, “Defects
Corrected in SY-1101211_K”, shows a list of the Change Requests that were
addressed in the SY-1101211_K release, including any Quick Fix releases containing
those Change Requests.
If the resolution is addressed by a maintenance release of SY-1101211_K, the
relevant maintenance release is indicated below.

Table 3 - Defects Corrected in SY-1101211_K

Change Maintenance Release/Quick Description


Request Fix Release
CAR#57845630 / Upon removing the Ethernet card and importing the .CFG
Defect#421555 file, duplicate Optonet cards are created in the .CFG file.
TDO card is unable to import due to incorrect creation in
SCD6000. It occupies two slots in SCD5200/SCD6000
SY-1101211_G6 instead of a single slot.
CAR#56698135 / While creating new CTVT in RTU Station and configuring
Defect#414596 card name of CTVT with custom name; the default point
names get truncated.
CAR#60126127 / Importing .CFG files gets stuck at 22%. Force shutting
Defect#437402 down the RTU Station results in partially imported
configuration showing DCB,DNP3, and nothing in DNP3
import list.
CAR#58656464 / SY-1101211_G7 RIAF report generator does not generate the points
Defect#426424 assigned to the Event logger.
CAR#59772120 / RTU Station detected issue with WISP+ and IDF after
Defect#434288 import. AI point used in IDF calculation has blank
parameters while importing into IDF calculation.
CAR#54233504 / Controls do not execute as entity numbers of points are not
Defect#399262 unique between Com 2 and Ethernet.
CAR#57714271 / RTU Station detected issue in generating .CFG file, points
Defect#420916 are missing while importing .CFG file.
CAR#58095279 / Detected issue while uninstalling RTU Station.
Defect#425436
CAR#59643501 / RTU Station G4 detected issue.
Defect#433713
CAR#59686446 / SY-1101211_G8 RTU Station detected issue after importing G3 .CFG file in
Defect#434393 G4, an error message "Access is denied" is reported
during IDF compilation.
CAR#59773417 / RTU Station detected issue in G4 and reports error during
Defect#434289 calc compilation in G4.
CAR#59852719 / RTU Station reports error message "Access is Denied"
Defect#434774 during Sall compilation.
CAR#61215779 / Missing DNP Slave TCP point information while importing
Defect#440594 a SCD5200 .CFG file into RTU station.

B0780SB, Rev N 11
RTU Station Release Notes Chapter 2: Changes Since Previous Release

Table 3 - Defects Corrected in SY-1101211_K (Continued)

Change Maintenance Release/Quick Description


Request Fix Release
CAR#58438281 / Detected issue while generating CFG file for RTU Station
Defect#425138 with DNP3 Slave configured as RTU1 and IEC61850 as
RTU2.
CAR#58850542 / DNP3 Slave does not update events due to G2 which
Defect#429106 SY-1101211_G9 produces SOE type DI points over Optonet. G1 works fine.
CAR#60730885 / Detected issue while importing CSV file containing 61850
Defect#439118 points into Node 1 NSC1 of DNP3 Slave Port 20000. The
points are left blank.
CAR#49545822 / SCD6000 Static Routes.
Defect#367115
CAR#64249920 / The RTU Station displays a warning message.
Defect#450340
Defect#380862 "NumberFormatException" is encountered while importing
CSV files to RTU50 SVX type RTU Station.
Defect#397063 SY-1101211_G10 Importing DNP3 Master configuration is unsuccessful
when Custom poll is configured in the Master unit.
Defect#405552 Detected issue while importing RTU Station CFG file for
DNP3 Slave with AO points.
Defect#425501 Detected issue while importing RTU Station CFG file for
DNP3 Slave configured on an 8-channel serial module.
Importing CSV files for Test Improvement Database files is
unsuccessful.
CAR#62516158 / Detected issue while importing 'gi', 'gi period' and 'demand
Defect#448097 inscan point' in IEC61850.
CAR#65137595 / SY-1101211_G11 The IDF calc causes the RTV to disconnect.
Defect#455780
Defect#380931 Detected issue while importing IEC 61850 Server
configuration and compiling the SALL files.
Defect#415886 RTU enters into bootstrap mode throwing error "IP Address
is not available" for IEC61850 Client Configuration.
Defect#463564 Unable to import IEC61850 Client when CFG contains
both IEC61850 client & IEC61850 server.
SY-1101211_G12
Defect#382721 Detected issue while importing DNP3 CSV files to RTU
Station.
CAR#66439199 / Invalid filename issue while importing CFG or IEC61850
Defect#460080 SCD files in SY-1101211_G11.
Defect#434431 While importing the CFG of IEC61850 server, the trusted
host data does not get reflected.
Defect#447192 On import and generation of GI, the GI data is not
displayed in CFG. The GI is enabled to False and demand
SY-1101211_G13 scan point is disabled.
Defect#413753 Import of the IEC61850 server files is unsuccessful and
mapped points are removed.
Defect#380928 On entering the demand scan point as Number in the RCB,
it displays the NumberFormatException .

12 B0780SB, Rev N
Chapter 2: Changes Since Previous Release RTU Station Release Notes

Table 3 - Defects Corrected in SY-1101211_K (Continued)

Change Maintenance Release/Quick Description


Request Fix Release
Defect#474807 Conitel Master scan points are not available for mapping in
other protocols.
Defect#382907 RTU goes into the Bootstrap mode when the IDF equation
is empty.
Defect#381516 RTU Station is accepting empty fields for Health, Service
Point and Scan Period (mandatory fields).
Defect#393144/ There is a multi-node issue detected for the SCD6000 &
Case#53629222 RTU50.
Defect#438159 Point entity number issue is detected while loading the
SCD file in the SCD6000.
Defect#405552 There is a issue detected with RTU Station CFG while
importing the DNP3 Slave AO points. After import some
points like IEC61850, IEC101, IEC103 and so on which are
mapped to DNP3 Slave are not visible in the GUI of DNP3
Slave.
Defect#407352 When you click on Datapoint window, the RTV displays an
invalid tool detected query error.
Defect#408514 After import, the DNP3 TCP and IEC61850 server displays
same channel number due to which the RTU enters into
the bootstrap mode.
Defect#421152 In DNP3 module, the frozen counter IEC61850 points are
not available for selection.
Defect#406959 The RTU does not ping for serial communication when
committing the Online file (ON file).
Defect#416211 Modbus Master connected via TCP\IP does not update the
changes made to connected IED's.
Defect#391448 RTU Station allows entering out of range port numbers.
Defect#416250 Unavailable Data Points are read as signed in Modbus
Master.
Defect#406417 SY-1101211_K The IEC61850 points does not update to Packed Single
point information objects in the IEC104 Slave.
Input validation fix for the IEC101 Master parameters:
ASDU Address, Min. and Max. values for the Setpoint
Normalized, Measured Scaled and Float type information
objects.
The IEC61850 points are not available for the IEC101
Master when IEC101 Slave with IEC61850 points are
attached to the IEC101 Master.
In the IEC101 Master, when you insert point address using
“Insert next and select point execute query” option, it
displays different values .
Defect#392185 Data exception on editing the IEC101 controlled station in
the RTU Station.
Defect#380927/ When the logical RTU address is configured in the IEC101
Defect#390015/ IED, it displays the Number Format Exception.
Defect#390017

B0780SB, Rev N 13
RTU Station Release Notes Chapter 3: Known Problems and Limitations

Chapter 3: Known Problems and Limitations


At the time of release, there are no outstanding priority 1 (top priority) defects
detected. However, some limitations are known to exist with the SY-1101211_K,
Foxboro RTU Station.
• (CAR#412054) Controls did not pass to operate on TCP/IP channel when you
have DNP3 Master protocol configured on both COM2 and TCP/IP channels.
This is due to the duplicate or non-generation of Entity Number in the
configuration file.
• To configure 104 Master redundancy, you need to manually set the backup
parameters to match the primary configuration.
• The Foxboro RTU Station creates a series of OptoNet nodes by importing
existing configuration files. During this process, it is necessary that point names
in the collective RTU database can be resolved by the time they are used. For
instance, the nodes containing the source points have to be imported before the
nodes that use those points. Any points that cannot be resolved are removed and
a system message is displayed. You need to intervene to restore the points. In
OptoNet network, user should generate CFG files for all the RTU's in the network,
instead of generating CFG files for individual RTU's.
• Foxboro RTU Station provides two options for Digital Output modules: TDO and
TDO 10Amp. When configuring the new SCD5200 8DO module, select the
“TDO” option and configure only the first eight relays. Configuring relays 9 to 12
causes the 8DO card to reject all controls and report a “configuration error”.
• The ASDU (Application Service Data Unit) packing strategy for station
interrogation and interrogation group data for IEC 60870- 5-101 Slave is sub-
optimal. In some cases, the Foxboro RTU Station causes the RTU to generate
several short messages where the number of long messages are limited for the
protocol. This may result in inefficient bandwidth utilization.
• GSSE (Generic Substation State Events) functionality is not supported in the
latest releases (SY-1101191_F or later) of Foxboro RTU Station. GSSE
functionality is supported in the older version of System Configurator (SY-
1101191_E) and RTU firmware (SY-1101205_A).
• The IEC103 DISOE (Digital Input Sequence of Events) points change to DI when
the database backup, created in Foxboro RTU Station versions prior to SY-
1101191_J1 release, is restored in Foxboro RTU Station version SY-1101191_J1
or later. To avoid the change of IEC103 DISOE points to DI:
◦ Restore the backup created in SY-1101191_J or prior versions.
◦ Generate the configuration files.
◦ Import the generated configuration files.
◦ Regenerate the configuration files.
• From the SY-1101191_L release, SALLHLSI (SALL High Level Serial Interface)
utility has been changed to a simple command line application with black and
white text. This change was implemented to enable the Foxboro RTU Station to
support Windows 7 or later supported OS versions, which does not support the
Full Screen Mode for Command Window.
• The Protocol Configuration program, SALLHLSI.EXE.The Protocol Configuration
program generates a protocol definition file with a .pdf extension
◦ If you do not have Admin rights in your system, the PDF is generated under
the user profile folder.
◦ If you have Admin rights in your system, the PDF is generated in the protocol
definition folder.
• During SALL Compilation, ignore Cygwin related warning messages.
• RTU Station does not launch and cannot access the postgresql database if there
are any issues with User Account Settings (CAR#45753726).

14 B0780SB, Rev N
Chapter 3: Known Problems and Limitations RTU Station Release Notes

• RTU Station does not launch and it cannot access the postgresql database if
there are any User permission issues.
• RTU Station sometimes is non-responsive when user tries to generate multiple
PLM file in parallel.
• When User account control settings are set to low for non admin users, below
issues will be observed on RTUstation:
◦ RTU station does not launch.
◦ Backup/Restore functionality may not work.
◦ IEC61850 configuration does not import.
• You must first install RTV/RTU Connect Secure/SCD6000 software and then
install RTU Station to avoid any read/write permission issues. RTU Station does
not have weak ACL Implementation, installing it in the end provides access
permissions to the Foxboro folder.
• RTU Station displays exception while restoring the backup database created in
SY01101211_D and earlier versions (Defect#413753 and Defect#413595).
• RTU Station truncates the default point names if the derived names exceed 25
characters (CAR#57806091).
• When you export the basic configuration and import it as a 5200, it deletes the
cards and shows the 10 I/O slot file. When you import it as a 6000, the cards are
pushed over to one slot and a new OptoNet card is placed into the slot
(CAR#57845630).
• IEC points are missing during the import (CAR#57714271).
• When you configure protocol points under slot zero serial and ethernet,
duplication of entity numbers are generated resulting in the detected failure of
control operation (CAR#54233504).
• When uninstalling RTU station version SY-1101211_B3, a detected error
message "1628:failed to complete installation" appears (CAR#58095279).
• IEC61850 client points are deleted when IEC61850 client points in one RTU are
mapped to DNP3 Slave in another RTU, and if any configuration changes are
made in any of the RTUs (CAR#58438281).
• The RTU Station does not allow point names configuration starting with a
numeral. (CAR#58619671).
• Foxboro RTU station SY-1101211 does not launch after installation since Cygwin
bash.exe gets blocked by Cylance Protect or an equivalent end point security
software due to additional security control. You should set up a security exception
for bash.exe application (whitelist) on your operating system (Windows®10 (64-
bit) and Windows Server® 2016 (64-bit)) to overcome this.
◦ To perform whitelisting, do the following:
1. Type secpol.msc in Run dialog box, press Enter. The Local Security
Policy Editor window opens.
2. In the security settings window, look for the policy in Software Restrictions
Policies (SRP).
3. If no policies are found, create a new policy.
4. After a new policy is created, double-click on the Enforcement,
Designated File Types & Trusted Publishers object types for whitelisting
the Cygwin bash.exe application.
◦ However, we recommend you contact the Schneider Electric network support
team and get bash.exe whitelisted.
• While downloading RTU CFG files viewing them in RTV, the Optonet signal ID
suddenly changes to 7362 (CAR#53629222).
• The RTU Station software allows privilege escalation (Standard User to System
Administrator) in the operating system. Consequently, vulnerability exists due to
write permissions being provided to a service executable that can be modified by
any standard user. Upon replacing this executable with a different file and

B0780SB, Rev N 15
RTU Station Release Notes Chapter 3: Known Problems and Limitations

rebooting the system, the 'new file' executes with administrator privileges. This
issue has been tested for both supported operating systems, Windows 10 (1803)
and Windows Server 2016 (CAR#64041681).
• Importing files and CSV import does not work for SCD6000 RTU nodes with two
file electrobus expansion files (CAR#67645711).
• Re-importing a .CID file containing an underscore "_" in the IED name, results in
missing IEC61850 configuration in the RTU station (Defect#474612).
• RTU Station displays an detected validation error message in the DNP3 Slave
serial even if the primary phone number is entered (Defect#445677).
• RTU station displays an detected error and does not map the points to packed
single points of IEC-101 Slave from select point window. You can map the points
individually for each point from the drop down (Defect#446092).
• RTU Station displays an unhandled exception due to the heap size issue
(Defect#462852).
• The DNP3 Slave .csv files are not imported into RTU Station configured with
9000 counter points (Defect#464929).
• Unable to map Conitel Master points in the IEC104 Slave command objects and
DNP3 slave objects (Defect#469361).
• RAIF report generation fails for the IEC61850 Server configuration
(Defect#444080/469900).
• The IDF equations do not have input validations (Defect#475972).
• The Integrated totals are not updated in the IEC101 Master for more than 2500
counter points (Defect#464922).
• You cannot import .csv files into files 2 and 3 on an electrobus expansion file
(Defect#465881).
• When you import and regenerate the Optonet configuration files, some points
disappear from the export block of regenerated CFG files. Those points are
related to IEC104 Slave and double command second slave points
(Defect#475985).
• Foxboro RTU Station version SY–1101211_G5 and above does not have
selection for Floating point in “Reg_IP” group of the Modbus IED. It is available for
selection in the older versions of the RTU Station. (Defect#478614).

16 B0780SB, Rev N
Chapter 4: Validation and Verification Statement RTU Station Release Notes

Chapter 4: Validation and Verification Statement


Foxboro RTU Station, SY-1101211_K, was thoroughly verified and validated before
release. The verification and validation strategy for this release consists of:
• Change Design and Code Reviews: The developers documented and reviewed
the design and source code of all baseline changes before integrating the source
code with the system.
• Incident Retest: An independent team prepared and documented the test cases
for each of the incidents addressed in this release. This retest helped ensure that
the incident was fixed satisfactorily without any consequent incidents due to the
modification.
• Manual Subsystem Test: Tests were performed to help ensure correct subsystem
operation in an integrated system configuration.
• Windows Compatibility Test: The SY-1101211_K Foxboro RTU Station software
was tested on Windows ® 10 (64-bit) and Windows ® Server 2016 (64-bit)
Operating Systems.
However, there may be undetected defects that arise in project usage patterns.

B0780SB, Rev N 17
Schneider Electric Systems USA, Inc.
38 Neponset Avenue
Foxboro, Massachusetts 02035–2037
United States of America

Global Customer Support: https://pasupport.schneider-electric.com

As standards, specifications, and design change from time to time,


please ask for confirmation of the information given in this publication.

© 2016–2020 Schneider Electric. All rights reserved.


B0780SB, Rev N

You might also like