User’s manual

CAP 540 *1.1


Configuration, Programming and
Setting tool
This manual belongs to:
Contents

Chapter Page

About this manual 1

Introduction 3

Application 7

Requirements 13

Installing the CAP 540 tool package 17

How to use CAP 540 25

Customer feedback report 47

1MRK 511 104-UEN*1.1-00


Software Registration Form 49

4
About this manual

This is the user’s manual for CAP 540*1.1

Document number: 1MRK 511 104-UEN

Version: 1.1

Revision: 00

Issue date: June 2001

Data subject to change without notice

We reserve all rights to this document, even in the event that a patent is issued and a
different commercial proprietary right is registered. Improper use, in particular repro-
duction and dissemination to third parties, is not permitted.

This document has been carefully checked. If the user nevertheless detects any
errors, he is asked to notify us as soon as possible.

The data contained in this manual is intended solely for the product description and is
not to be deemed to be a statement of guaranteed properties. In the interests of our
customers, we constantly seek to ensure that our products are developed to the latest
technological standards.

As a result, it is possible that there may be some differences between the HW/SW
product and this information product.

Author´s address:
ABB Automation Products
Substation Automation Division
SE-721 59 Västerås
Tel: +46 (0) 21 32 13 00
Fax: +46 (0) 21 14 69 18
Internet: http://www.abb.com/automation

© ABB Automation Products AB 2001

1MRK 511 104-UEN*1.1-00 1


2
Introduction

Introduction ............................................................................................................. 5

Intended use of this manual ................................................................................. 5

Intended audience................................................................................................ 5
Responsibilities ............................................................................................... 5

What is in this manual? ........................................................................................ 5

How to find more information ............................................................................... 6

1MRK 511 104-UEN*1.1-00 3


Introduction

4
Intended use of this manual
Introduction

Introduction

1 Intended use of this manual


CAP 540 is a collection of programming, configuration and setting tools and libraries
for a range of protection and control terminals.

This manual can be used to get an overview of CAP 540 and its contents and informa-
tion on PC requirements and supported terminal product families. It also provides nec-
essary information to install the tool package CAP 540.

2 Intended audience
This manual can be used by installers, commissioners and system engineers.

2.1 Responsibilities
In order to fully understand the contents of this manual, you should have basic engi-
neering knowledge and specific knowledge in system automation, depending on your
purpose.

3 What is in this manual?


This manual is organized into chapters according to the intended audience so that each
chapter corresponds to user’s needs.

Chapter 1 gives an introduction to the manual.

Chapter 2 gives an overview of CAP 540 and its contents.

Chapter 3 specifies the requirements for your PC and operative system. It also shows
which product families and releases are supported by this tool package.

Chapter 4 describes how to install the CAP 540 tool package.

Chapter 5 describes how to use the CAP 540 tool.

1MRK 511 104-UEN*1.1-00 5


How to find more information
Introduction

4 How to find more information


The following manuals provide complementary information:

• CAP 531*1.6 Configuration and Programming tool, User’s Manual,


1MRK 511 105-UEN
• PST*1.1 Parameter Setting tool, User’s Manual, 1MRK 511 089-UEN
• REVAL*2.0, User´s Manual, 1MRK 002 203-AA

6 1MRK 511 104-UEN*1.1-00


Application

Application............................................................................................................... 9

Tool package CAP 540 ........................................................................................ 9

1MRK 511 104-UEN*1.1-00 7


Application

8 1MRK 511 104-UEN*1.1-00


Tool package CAP 540
Application

Application

1 Tool package CAP 540

The tool package CAP 540 contains these programming, configuration and setting tools and
libraries for a range of protection and control terminals:

• CAP 531*1.6; configuration and programming tool


• Configuration library for terminal REx 5xx*2.0, 2.1, 2.2, 2.3 and 3.0
• Configuration library for terminal RET521*2.1,2.2,2.3,3.0
• PST Parameter Setting Tool, ver 1.1
• Parameter setting library for terminal REx 5xx*2.0, 2.1, 2.2, 2.3 and 3.0
• Parameter setting library for terminal RET 521*2.1, 2.2, 2.3 and 3.0
The package also contains the User’s Manuals for the tools in pdf-format and Acrobat Reader
to view the manuals.

Internet Explorer 4 is also provided. It is needed for the help system in PST.

1MRK 511 104-UEN*1.1-00 9


Tool package CAP 540
Application

When you install CAP 540*1.1 software you get the following tools and libraries:

Table 1: Included tools and libraries.

Tool/Library Release Description


CAP 531 1.6 The configuration and programming tool
CAP/REX50020 2.0 Configuration library for terminal REX 500 * 2.0
CAP/REX50021 2.1 Configuration library for terminal REX 500 * 2.1
CAP/REX50022 2.2 Configuration library for terminal REX 500 * 2.2
CAP/REX50023 2.3 Configuration library for terminal REX 500 * 2.3
CAP/REX50030 3.0 Configuration library for terminal REX 500 * 3.0
CAP/RET52121 2.1 Configuration library for terminal RET 521 * 2.1
CAP/RET52122 2.2 Configuration library for terminal RET 521 * 2.2
CAP/RET52123 2.3 Configuration library for terminal RET 521 * 2.3
CAP/RET52130 3.0 Configuration library for terminal RET 521 * 3.0
PST 1.1 The parameter setting tool
PST/REX50020 2.0 Parameter setting library for terminal REX 500 * 2.0
PST/REX50021 2.1 Parameter setting library for terminal REX 500 * 2.1
PST/REX50022 2.2 Parameter setting library for terminal REX 500 * 2.2
PST/REX50023 2.3 Parameter setting library for terminal REX 500 * 2.3
PST/REX50030 3.0 Parameter setting library for terminal REX 500 * 3.0
PST/RET52121 2.1 Parameter setting library for terminal RET 521 * 2.1
PST/RET52122 2.2 Parameter setting library for terminal RET 521 * 2.2
PST/RET52123 2.3 Parameter setting library for terminal RET 521 * 2.3
PST/RET52130 3.0 Parameter setting library for terminal RET 521 * 3.0

When you install the documentation for CAP 540*1.1, you get the following docu-
ments:

Table 2: Documents CAP 540

Document Number
CAP 540 * 1.1 (This document) 1MRK 511 104-UEN
Configuration, programming and setting tool package
User’s Manual
CAP 531 * 1.6 1MRK 511 105-UEN
Configuration and Programming tool
User’s Manual
PST * 1.1 1MRK 511 089-UEN
Parameter Setting tool
User’s Manual

10 1MRK 511 104-UEN*1.1-00


Tool package CAP 540
Application

Table 2: Documents CAP 540

Document Number
REVAL*2.0 1MRK 002 203-AA

1MRK 511 104-UEN*1.1-00 11


Tool package CAP 540
Application

12 1MRK 511 104-UEN*1.1-00


Requirements

Requirements ........................................................................................................ 15

PC, operative system and help viewer............................................................... 15

Product family support ....................................................................................... 15

1MRK 511 104-UEN*1.1-00 13


Requirements

14 1MRK 511 104-UEN*1.1-00


PC, operative system and help viewer
Requirements

Requirements

1 PC, operative system and help viewer

Table 1: Requirements on PC

Item Minimum required


Processor / Frequency Pentium / 166 MHz
RAM 64 MByte
Disk space 150 MByte
Monitor / Resolution VGA compatible / 800 x 600, 256 colors
CD-ROM drive Needed to install the tool package

Table 2: Requirements on operative system and help viewer


Operative System Release Help viewer
Windows NT 4 4.0 Service Pack 4 or higher Internet Explorer 4 or later
Windows 98 Second Edition Internet Explorer 4 or later
Windows 2000 - Internet Explorer

2 Product family support


The following product families and releases are supported by this tool package:

Table 3: Supported product families

Product family Releases Description


REX500 *2.0, *2.1, *2.2. The REX500 series of control and protection ter-
*2.3 and *3.0 minals.
RET521 *2.1, *2.2 *2.3 The RET521 transformer protection terminal.
and *3.0

1MRK 511 104-UEN*1.1-00 15


Product family support
Requirements

16 1MRK 511 104-UEN*1.1-00


Installing the CAP 540 tool
package

Installing the CAP 540 tool package ................................................................... 19

Installing the CAP 540 tool package .................................................................. 19

Uninstalling the CAP 540 software..................................................................... 21

1MRK 511 104-UEN*1.1-00 17


Installing the CAP 540 tool
package

18 1MRK 511 104-UEN*1.1-00


Installing the CAP 540 tool package
Installing the CAP 540 tool

Installing the CAP 540 tool package


This chapter describes how to install the different parts in the CAP 540 tool package.

Note!
When installing in Windows NT, you need to log in as administrator.Installing the
CAP 540 software

1 Installing the CAP 540 tool package

This section describes how to install the CAP 540 software.

1 Insert the CAP 540 installation CD in the CD-ROM drive of your personal com-
puter.
2 Double-click setup1.exe using Windows Explorer
Enter your name in the first dialog. This name will appear under “Licensed to:”.
Then the following dialog appears:

3 Read the message and click Next if you want to continue with the installation.
The following dialogue appears:

1MRK 511 104-UEN*1.1-00 19


Installing the CAP 540 tool package
Installing the CAP 540 tool

4 Select the drive and the folder where the CAP 540 software shall be installed,
and then click Next.
The following dialogue appears:

5 Click Next to continue


The CAP 540 software package is now being installed in your computer, showing
you a installation progress bar. Then the following dialogue appears:

20 1MRK 511 104-UEN*1.1-00


Uninstalling the CAP 540 software
Installing the CAP 540 tool

6 Click Finish button and the installation is completed.

7 Next step is to install CAP and PST or PST only


* Double-click setup2.exe using Windows Explorer. You will now install PST but
also CAP531 if configuration has been ordered.

* Follow the instructions on the screen. until the installation is finished. You may
then have to restart the computer.

8 Acrobat Reader and Internet Explorer.


*The CD-ROM contains also Acrobat Reader and Internet Explorer

*You have to continue with installing Acrobat Reader if you don’t have this pro-
gram installed already on your computer.

*The help function in the Parameter Setting Tool uses Internet Explorer. If you do
not have Internet Explorer on your computer, you have to install it.

2 Uninstalling the CAP 540 software


This chapter describes how to uninstall the CAP 540 software

21
Uninstalling the CAP 540 software
Installing the CAP 540 tool

1 Double click the Program CAP 540 Uninstall or Select the Control Panel in the
Start menu.
2 If you select the Control panel, double-click Add/Remove Programs, and then
Click the Install/Uninstall tab
The following dialog appears: (Example from uninstalling a version of CAP 540)

3 Select CAP 540 in the list and then click Add/Remove


The uninstall for CAP 540 starts and the following dialog appears:

22 1MRK 511 104-UEN*1.1-00


Uninstalling the CAP 540 software
Installing the CAP 540 tool

4 Click Automatic, and then click Next


The following dialog appears:

5 Click Finish to start the uninstallation


The CAP 540 software is now uninstalled, showing you a progress bar.

23
Uninstalling the CAP 540 software
Installing the CAP 540 tool

24 1MRK 511 104-UEN*1.1-00


How to use CAP 540

How To Use CAP 540 ............................................................................................ 27

Navigate in CAP 540.......................................................................................... 27


How to Log on............................................................................................... 27
How to build a new project tree..................................................................... 29

Configuration of terminals with CAP 531 ........................................................... 32


How to start CAP 531 from terminal level in CAP 540 .................................. 32

Parameter setting............................................................................................... 35

Disturbance upload ............................................................................................ 37


Station level .................................................................................................. 37
Terminal level................................................................................................ 38
Disturbance records ...................................................................................... 39

Disturbance Evaluation and Analysis................................................................. 42

Other Programs.................................................................................................. 43

Compress/Decompress...................................................................................... 46

Exit CAP 540...................................................................................................... 46

1MRK 511 104-UEN*1.1-00 25


How to use CAP 540

26 1MRK 511 104-UEN*1.1-00


Navigate in CAP 540
How To Use CAP 540

How To Use CAP 540


This section describes how to navigate in CAP 540 and perform Configuration, Param-
eter setting, Disturbance upload and Disturbance evaluation.

1 Navigate in CAP 540

CAP 540 is used through all stages of normal operation from parameter setting, com-
missioning and power system disturbance evaluation. It can also be used to clear front
indications, switch setting groups and turn autoreclosure on/off. The engineering work
can be done off-line on the PC. The configuration is prepared and tested before the
commissioning. The system for disturbance upload is prepared and tested during com-
missioning.

1.1 How to Log on


In order to use CAP 540 it must be installed in your computer; see How to install CAP
540. When starting CAP 540 the following Log On dialogue appears.

1MRK 511 104-UEN*1.1-00 27


Navigate in CAP 540
How To Use CAP 540

Fill in User Id, Password and click OK.This dialogue contains the possibility to change
the password. Note that the password may have been linked by the Administrator to a
certain authority level.

If you logon in the capacity of System Administrator you can select System and arrive
at the following dialogue

28 1MRK 511 104-UEN*1.1-00


Navigate in CAP 540
How To Use CAP 540

If you then click Users the following dialogue appears where you can define authority
levels .

1.2 How to build a new project tree


When you have logged on the following screen appears:

1MRK 511 104-UEN*1.1-00 29


Navigate in CAP 540
How To Use CAP 540

Prj1 is a default name. Use right mouse button and select Rename. Fill in the name of
the whole structure e.g. a Power Network name like SouthNet or similar. Then click
the folder SouthNet with right mouse button, choose Add and continue to add Stations
and Bays according to your network.

When you have filled in all names your tree may look like below:

When you position the cursor on folders below top level you can as you have seen
remove and rename. Please observe: If you remove a folder or object all files like
configuration and disturbance data will also be deleted.

30 1MRK 511 104-UEN*1.1-00


Navigate in CAP 540
How To Use CAP 540

The last level is the Terminal level. Choose one bay, right click and Add. Then a sup-
porting dialogue appears where you can choose the proper terminal e.g. REL521*2.3

Choose a vacant slave number (they must be unique for each terminal that belongs to
the same polling circuit)

Then the structure may look as this: (Example of a complete structure down to the
final leaf)

1MRK 511 104-UEN*1.1-00 31


Configuration of terminals with CAP 531
How To Use CAP 540

2 Configuration of terminals with CAP 531

Note: The Configuration Program CAP531 is an optional feature in CAP 540.

The default configuration in the terminals is easily adapted to the customer’s needs.
The configuration consists of function blocks, logic gates and timers. The function
blocks included in a terminal are available in a library of functions, where the engineer
can pick a function and connect it according to the requirements.

CAP 531 offers a compilation check to help the engineer to make a correct configura-
tion.

The monitoring function provides an on-line check of all internal signals in a 500-ter-
minal. It offers a window into the terminal, where the commissioner can see all
changes in signal status. With this tool, the commissioner obtains a powerful help.

CAP 531 is used by the protection engineer that, for example, adapts the scheme com-
munication logic in a line protection to the customer’s requirements.

It is also used by the control system constructor that for example adapts the interlock-
ing logic to the switchgear configuration of the station.

The configuration can be printed on a user-defined form which gives documentation of


the configuration that matches the terminal completely.

2.1 How to start CAP 531 from terminal level in CAP 540
Position the cursor on Terminal level and click right button.

32 1MRK 511 104-UEN*1.1-00


Configuration of terminals with CAP 531
How To Use CAP 540

Select Terminal configuration. The following picture appears after logging in.

See the CAP 531 manual for further guidance how to configurate terminals. For
instance, Import of an earlier done CAP 531 Configuration can be done by the follow-
ing steps:

1MRK 511 104-UEN*1.1-00 33


Configuration of terminals with CAP 531
How To Use CAP 540

Select a terminal in the SMS navigator, select in the File menu; Import of a CAP 531
Configuration. Select an old CAP 531 project.tre file. The screen below appears.

In the CAP 531 Navigator, select the terminal from which you want to import the con-
figuration. Click the right mouse button and select Copy Terminal Configuration . An
arrow appears at the selected terminal as shown below.

34 1MRK 511 104-UEN*1.1-00


Parameter setting
How To Use CAP 540

In the SMS Navigator, select the target terminal. Click the right mouse button and
select Paste CAP 531 Configuration.

3 Parameter setting

Start the Parameter setting, PST, from a terminal node with a right mouse click. The
following dialogue appears.

1MRK 511 104-UEN*1.1-00 35


Parameter setting
How To Use CAP 540

Click Parameter Setting with left mouse button and the following screen appears.

Then continue according to the manual for PST (Parameter Setting).

36 1MRK 511 104-UEN*1.1-00


Disturbance upload
How To Use CAP 540

4 Disturbance upload

4.1 Station level


Position the cursor on Station level and click right mouse button.Continue with Distur-
bance handling and with any of the active choices in next dialogue (Station Distur-
bance upload or Station Disturbance File Transfer depending on if there is a station pc
or not).

1MRK 511 104-UEN*1.1-00 37


Disturbance upload
How To Use CAP 540

In the Communication Settings dialogue the communication parameters, modem types


and disturbance autopolling options are set up as shown in the picture below.

4.2 Terminal level


Position the cursor on Terminal level and click right button. Continue with Distur-
bance Handling and with any of the active choices in next dialogue (terminal distur-
bance list or terminal disturbance file list depending on if there is a station pc or not). It
is also possible to trig the disturbance recorder manually, clear indications or clear all
disturbances.

38 1MRK 511 104-UEN*1.1-00


Disturbance upload
How To Use CAP 540

4.3 Disturbance records


shows the resulting data, four different displays: the list of disturbances (or list of dis-
turbance files if you work from a Central computer towards Station computer) and
three other displays of disturbance information data.

1MRK 511 104-UEN*1.1-00 39


Disturbance upload
How To Use CAP 540

The top display is the list of disturbances and will indicate with red color new distur-
bances and with blue for uploaded disturbances. By clicking the right mouse button
when in a red row (new disturbance) you will arrive at the following dialogue.

From this dialogue you can e.g. upload the selected disturbance from the terminal.

40 1MRK 511 104-UEN*1.1-00


Disturbance upload
How To Use CAP 540

By clicking right mouse button on an uploaded disturbance (black) you get the follow-
ing dialogue.

From this dialogue you can start Disturbance Evaluation (REVAL).

By clicking left button on an uploaded disturbance you will get additional information
in the lower three displays, analog channels, digital channels and events.

1MRK 511 104-UEN*1.1-00 41


Disturbance Evaluation and Analysis
How To Use CAP 540

5 Disturbance Evaluation and Analysis

Disturbance evaluation with the program REVAL can be started by double clicking the
disturbance, clicking the icon for REVAL in the toolbar and browse the available files
or from the dialogue when right clicking an uploaded disturbance. The chart will
appear as below. You can there study the analogue curves and the digital signals.

Refer to the REVAL manual for further guidance.

42 1MRK 511 104-UEN*1.1-00


Other Programs
How To Use CAP 540

6 Other Programs

In the pull-down menu you can find some more programs:

SMS-base is used for earlier versions of relay terminals that are not supported by PST.

CAP 540 will automatically recognize replacement PST modules for earlier Terminal
versions when copied into the PST structure.

1MRK 511 104-UEN*1.1-00 43


Other Programs
How To Use CAP 540

Time Scheduler is used when specifying a time for starting disturbance uploading.

Terminal emulator can be useful for fault tracing when setting up the communication
system. Select a terminal and then Terminal Emulator in the Pull-down menu.

44 1MRK 511 104-UEN*1.1-00


Other Programs
How To Use CAP 540

Time Synchronization is used when setting up the synchronization of all terminals in


the station connected to same loop.

1MRK 511 104-UEN*1.1-00 45


Compress/Decompress
How To Use CAP 540

FTP is a File Transfer Protocol used when sending the disturbance files via a network
to a FTP server.

7 Compress/Decompress
In the File menu you can find the option compress and decompress. This can be used
when moving a project to another computer.

8 Exit CAP 540


Click File/Exit or the X sign.

46 1MRK 511 104-UEN*1.1-00


Customer feedback report

Product:

ABB Automation Products AB would appreciate your comments on this product.


Please grade the following questions by selecting one alternative per category. Your
answer will enables us to improve our products.

How do you grade the quality of the product?


Excellent Poor

Total impression

Useability

Functionality

Human-man interface

Comments: __________________________________________________________

____________________________________________________________________

____________________________________________________________________
Remove from binder

How do you grade the quality of the documentation?


Excellent Poor

Total impression

Layout

Illustrations

Readability

Easy to find

Content structure

Comments: __________________________________________________________

____________________________________________________________________

____________________________________________________________________

47
Customer feedback report

Suggestions for improvments:


_____________________________________________________________________

_____________________________________________________________________

_____________________________________________________________________

_____________________________________________________________________

_____________________________________________________________________

_____________________________________________________________________

_____________________________________________________________________

_____________________________________________________________________

_____________________________________________________________________

_____________________________________________________________________

_____________________________________________________________________

_____________________________________________________________________

Remove from binder


_____________________________________________________________________

_____________________________________________________________________

Please send this report to:


ABB Automation Products AB
Substation Automation Division
SA-T, Support Line
SE-721 59 Västerås
Sweden

By facsimile:

Send to + 46 (0) 21 14 69 18

48
Software Registration Form

Program:

This card registers your program and makes you eligible to receive information about
future updates.

Name:

_____________________________________________________________________________________
Title:

____________________________________________________________________________________
Company: Dept.

____________________________________________________________________________________
Address:

____________________________________________________________________________________

____________________________________________________________________________________
City: State: Zip:

____________________________________________________________________________________
Phone:

____________________________________________________________________________________
Fax:

____________________________________________________________________________________
Remove from binder

Program supplied by:

____________________________________________________________________________________
Adress:

____________________________________________________________________________________

____________________________________________________________________________________
City: State: Zip:

____________________________________________________________________________________
Phone:

____________________________________________________________________________________
Date of receival of the program:

____________________________________________________________________________________
Program serial Nr:

____________________________________________________________________________________

Fascimile:
Please send this registration card to ABB Automation Products AB, Sweden department Substation Auto-
mation, SA-T, Support Line (+46 21 14 69 18).

49
Place
Postage
Here

ABB Automation Products


Substation Automation Division
SA-T, Support Line
SE-721 59 Västerås
Sweden

Remove from binder


To be folded

Tape here
ABB Automation Products AB

License Agreement
IMPORTANT - READ CAREFULLY BEFORE OPENING
This legal document is an agreement between You, the user, and ABB Automation Products AB,Västerås, SWEDEN. By opening
the diskette package You indicate your acceptance of the terms and conditions of this agreement. If You do not agree to the
terms of this agreement, promptly return the unopened diskette package and other items which are part of the product for a full
refund. Your product is a single user version unless you have a written agreement with ABB Automation Products AB.

SOFTWARE LICENSE

1. Grant of License • This ABB Automation Products AB License Agreement (”License”) grants you the nonexclusive right to use
one copy of the enclosed software program (”SOFTWARE”) on a single computer (i.e., with a single CPU) at
a single location at any time. If you have multiple Licenses for the SOFTWARE you may have as many copies
of the SOFTWARE in use as you have Licenses.

2. Copyright • The software is owned by ABB Automation Products AB or its suppliers and is protected by Swedish
copyright laws, international treaty provisions, and all other applicable national laws. Therefore you must treat
the SOFTWARE as any other copyrighted material (e.g., a book or musical recording) except that if the
software is not copy protected you may either (a) make a copy of the SOFTWARE solely for backup or archival
purposes, or (b) transfer the SOFTWARE to a single hard disk provided you keep the original solely for
backup or archival purposes. You may not copy the Documentation accompanying the SOFTWARE.

3. Term • The License is effective until terminated. This License will terminate automatically without notice from
ABB Automation Products AB if you fail to comply with any provision of this License. Upon termination you
shall return the diskettes containing the SOFTWARE and all Documentation to ABB Automation Products AB
and destroy any copies of the SOFTWARE or any portions of it which has not been returned to ABB
Automation Products AB, including copies resident in computer memory.

4. Other Restrictions • You may not rent, lease, lend, sell or give away the SOFTWARE, but you may transfer your rights under
this ABB Automation Products AB License Agreement on a permanent basis provided you transfer all copies
of the SOF TWARE and all written materials, and the recipient agrees to the terms of this Agreement. You
may not modify, adapt, translate, reverse engineer, decompile, disassemble, or create derivative works based
on the SOFTWARE. You may not modify, adapt, translate or create derivative works based on the written
materials.

LIMITED WARRANTY

Limited Warranty • ABB Automation Products AB warrants that the software will perform substantially in accordance with the
accompanying Product Manual(s) for a period of 1 year from the date of delivery from ABB Automation Products
AB, Västerås. ABB Automation Products AB does not warrant that the SOFTWARE is free from coding errors.

Customer Remedies • ABB Automation Products AB’s entire liability and your exclusive remedy shall be, at ABB Automation
Products AB’s option, either (a) return of the price paid or (b) repair or replacement of the SOFTWARE that
does not meet ABB Automation Products AB’s Limited Warranty and which is returned to ABB Automation
Products AB with a copy of your receipt. This Limited Warranty is void if failure of the SOFTWARE has
resulted from accident, abuse, or misapplication. Any replacement SOFTWARE will be warranted for the
remainder of the original warranty period or 30 days, whichever is longer.
No Other Warranties • ABB Automation Products AB disclaims all other warranties, either express or implied, including but not
limited to implied warranties of merchantability and fitness for a particular purpose, with respect to the SOFT-
WARE, accompanying Product Manual(s) and written materials. This warranty gives you specific legal rights.
No Liability for
Consequential Damages • Neither ABB Automation Products AB nor anyone else who has been involved in the creation, production or
delivery of this product shall be liable for any direct, indirect, consequential or incidental damages (including
damages for loss of business profits, business interruption, loss of business information, and the like) arising
out of the use or inability to use such product even if ABB Automation Products AB has been advised of the
possibility of such damages. In any case, ABB Automation Products AB's entire liability under any provision
of this agreement shall be limited to the amount actually paid by you for the software.

ACKNOWLEDGEMENT
By opening the diskette package you acknowledge that you have read this agreement, understand it, and agree
to be bound by its terms and conditions. You also agree that it is the complete and exclusive statement of the
agreement between the parties and supersedes all proposals or prior agreement, oral or written, and any other
communications between the parties relating to the subject matter of the licence or limited warranty.

This Agreement is governed in all aspects by Swedish law. If any provisions of this Agreement are invalid or
unenforceable, all others will remain in effect.
1MRK 511 104-UEN

ABB Automation Products AB


Substation Automation Division
SE-721 59 Västerås
Sweden
Tel: +46 (0) 21 34 20 00
Fax: +46 (0) 21 14 69 18 Printed on recycled and ecolabelled paper

You might also like