1900/65
General Purpose Equipment Monitor fact sheet
Traditional Bently Nevada* monitoring systems like the 3500 Benefits
Series are widely recognized for protecting large, complex
• Lower-cost, continuous online protection than traditional
rotating machinery. However, it is generally difficult to justify
rack-based systems
this type of continuous monitoring for less critical, essential
or general purpose equipment. As a result, these machines • Digital connectivity via optional Modbus® gateway serves
typically operate without adequate protection. rich static variable set, alarm statuses, and event list data to
Distributed Control Systems (DCSs), Programmable Logic
The Bently Nevada 1900/65 General Purpose Equipment Controllers (PLCs), Supervisory Control and Data Acquisition
Monitor is a flexible, cost-effective system specifically designed (SCADA) Systems, and System 1* Optimization and
to continuously monitor and protect essential Diagnostic Software
and balance-of-plant equipment assets in a wide range
• Reliable system offers improved capability over transmitters
of industries including: Oil & Gas, Power Generation, Water
for equipment protection
Treatment, Pulp & Paper, Manufacturing, Mining, Cement,
• Uses proven and reliable circuit designs as found in 3500
and others. The 1900/65 Monitor is suitable for monitoring
and 3300 monitoring systems
and protecting cooling tower fans, pumps, blowers, motors,
pulverizers, air compressors, small reciprocating compressors, • 8-channel monitor offers greater number and variety of
small electric motors, small hydro turbines, centrifuges, and inputs than other 1900 Series monitors
other equipment assets. • Easy installation and configuration through small size,
flexible mounting options, and configuration software
• Up to 8 pole filters on some variables • Optional fiberglass housing, or steel door (for panel-mount
applications), to meet weatherproof installation
• 24 bit A/D converters with 25 kHz bandwidth
requirements and IP65
• 4 channels of temperature inputs (type E, J, K, and T
• Approvals include CSA (Class 1 Div 2 - although the monitor
thermocouples)
cannot be installed in Div 1 locations, it will support
• 2 levels of alarms – ALERT and DANGER transducers installed in Div 1 locations via the use of
• 6 configurable relays with voting logic isolators and barriers), ATEX (Zone 2), CE, and GOST (IEC Ex)
• Buffered transducer outputs – 4 on monitor, 1 on display
—