You are on page 1of 4

Needle Valves

with and without


Reverse Flow Check
Direct-Acting
Inline Mounted - 350 bar
up to 180 l/min
up to 350 bar DV- / DRV- 06 to 16
FUNCTION FEATURES
zz For regulating the speed of loads
zz For fine adjustment and shut-off of the flow
DV zz For system-related damping in hydraulic circuits
zz To release pressure from accumulator systems
zz As an emergency drain for lowering a load without a dead man's circuit
zz Spindle secured before complete loosening
zz An Allen set-screw locks the setting of the knob
zz Choice of five sizes ensures best possible adaptability to the system
zz Drop forged housings with high safety factor

DRV

SPECIFICATIONS*
Operating pressure: max. 350 bar
Nominal flow: DV- / DRV-06 max. 20 l/min
DV- / DRV-08 max. 50 l/min
DV- / DRV-10 max. 60 l/min
DV- / DRV-12 max. 90 l/min
DV- / DRV-16 max. 180 l/min
Cracking pressure (DRV): 0.5 bar
Media operating temperature range: min. -20 °C to max. +100 °C
Ambient temperature range: min. -20 °C to max. +100 °C
The DV is an inline mounted flow Operating fluid: Hydraulic oil to DIN 51524 Part 1, 2 and 3
control valve which controls the flow by
adjusting the cross-section. The flow rate Viscosity range: min. 2.8 mm²/s to max. 800 mm²/s
is therefore dependent on the pressure Filtration: Class 21/19/16 according to ISO 4406 or
differential and viscosity. Starting with the cleaner
throttle spindle in the fully closed position, Installation: no orientation restrictions, preferably
the flow rate increases in accordance with horizontal
the appropriate curve as the control knob
Materials: Valve body: steel
is turned. The flow is controlled in both
directions. The scale on the lower edge of Piston: hardened and ground steel
the control knob enables accurate repeat Seals: FKM (standard)
setting. Back-up rings: PTFE
The DRV is a flow control valve in the
EN 5.119.11/09.19

same design which also allows the same Weight: DV-06 = 0.10 kg DRV-06 = 0.10 kg
fine flow adjustment, but in one direction DV-08 = 0.26 kg DRV-08 = 0.28 kg
only. Unrestricted flow in the reverse DV-10 = 0.38 kg DRV-10 = 0.41 kg
direction is via the built-in check valve DV-12 = 0.62 kg DRV-12 = 0.65 kg
(cracking pressure 0.5 bar). DV-16 = 1.04 kg DRV-16 = 1.14 kg
* see "Conditions and instructions for valves" in brochure 53.000
1
Standard models
MODEL CODE
Model code Part No.
DRV – 08 – 01 . X / 0 DV-06-01.X/0 705002
Basic model DV-08-01.X/0 705014
DV = Needle valve DV-10-01.X/0 705026
DRV = Needle valve with reverse flow check
DV-12-01.X/0 705038
Nominal size DV-16-01.X/0 705050
06, 08, 10, 12, 16
DRV-06-01.X/0 705502
Type DRV-08-01.X/0 705514
01 = standard, housing zinc-plated DRV-10-01.X/0 705526
11 = housing zinc-plated, fine throttle spindle
DRV-12-01.X/0 705538
in stainless steel
12 = housing zinc-nickel plated (seawater-resistant), DRV-16-01.X/0 705550
fine throttle spindle in steel, with protective Other models on request
dome nut - adjustment with tool
Other types on request Accessories
Panel mounting sets, nickel-plated, consisting of locking washer,
Series
disc and hex. nut
(to be determined by manufacturer)
Size Part No.
Threaded connection
06 705309
0 = Whitworth thread,
threaded connection Form X to DIN 3852 Part 2 08 705310
5 = NPT thread 10 705310
12 = UNF thread 12 705311
Note: Spindle slightly open on delivery. 16 705311
EN 5.119.11/09.19

2
TYPICAL PERFORMANCE
Pressure drop, dependent on flow rate DV- / DRV-12-01 A→B
DV = flow direction A → B is equivalent to B → A
flow setting in turns
DRV = flow direction A → B
1 2 3 4 5
Pressure differential ∆p measured against flow rate Q, 100

measured at constant flow setting, ν = 53 mm²/s and Toil = 36 °C 90

80

Pressure differential ∆p [bar]


70
DV- / DRV-06-01 A→B
60
6
flow setting in turns
50
0,5 1 1,5 2 2,5 3
100 7
40
8
90
30
80
Pressure differential ∆p [bar]

20
70
3,5 10
60
0
50 0 10 20 30 40 50 60 70 80 90
Flow rate [l/min]
40 4
4,5
30 5

20 DV- / DRV-16-01 A→B


10 flow setting in turns
0 1 2 3 4 5 6 7
0 2 4 6 8 10 12 14 16 18 20 100

Flow rate [l/min] 90

80
Pressure differential ∆p [bar]

8
70
DV- / DRV-08-01 A→B
60 9
flow setting in turns
50 10
1 2 3
100
40
90
4 30
80
Pressure differential ∆p [bar]

5 20
70
6 10
60 7
0
50 0 20 40 60 80 100 120 140 160 180
Flow rate [l/min]
40

30

20

10

0
0 5 10 15 20 25 30 35 40 45 50
DRV-06 to 16 B→A
Flow rate [l/min]

10

DV- / DRV-10-01 A→B


12

8
10
Pressure differential ∆p [bar]

flow setting in turns


DR
DRV 08

DRV

1 2 3 4
100
DRV 06

6
90

80
Pressure differential ∆p [bar]

5 4
70 16
DRV
60
2
50
6
40
0
7
30 0 20 40 60 80 100 120 140 160 180 200
Flow rate [l/min]
20

10

0
EN 5.119.11/09.19

0 5 10 15 20 25 30 35 40 45 50 55 60
Flow rate [l/min]

3
DIMENSIONS
DV DRV
Type 01 and 11 12 Type 01 and 11 12

open

open
closed

closed
millimeter millimeter
subject to technical modifications subject to technical modifications

Size Threaded A B C SW E Size Threaded A B C SW E


connection connection
06 G⅛ 57 52.9 9 16 19 06 G⅛ 57 52.9 9 16 28.8
08 G¼ 70.4 64.3 14.2 25 24 08 G¼ 70.4 64.3 14.2 25 34
10 G⅜ 76.6 70.8 17.1 30 29 10 G⅜ 76.6 70.8 17.1 30 42
12 G½ 89.2 82.3 20 35 34 12 G½ 89.2 82.3 20 35 44
16 G¾ 106.2 97.3 25.7 45 39 16 G¾ 106.2 97.3 25.7 45 57

F G J SW1 SW2 X Weight [kg] F G J SW1 SW2 X Weight [kg]


38 25.2 Pg7 3 10 58.6 0.094 45 25.2 Pg7 3 10 58.6 0.103
48 30.5 Pg11 4 13 72.3 0.257 55 30.5 Pg11 4 13 72.3 0.277
58 30.5 Pg11 4 13 78.8 0.378 65 30.5 Pg11 4 13 78.8 0.407
68 38 Pg16 5 17 89.3 0.618 73 38 Pg16 5 17 89.3 0.644
78 38 Pg16 6 19 111.3 1.038 88 38 Pg16 6 19 111.3 1.139

NOTE
EN 5.119.11/09.19

The information in this brochure relates to HYDAC Fluidtechnik GmbH


the operating conditions and applications Justus-von-Liebig-Str.
described.
For applications or operating conditions not D-66280 Sulzbach/Saar
described, please contact the relevant Tel: 0 68 97 / 509-01
technical department. Fax: 0 68 97 / 509-598
Subject to technical modifications. E-Mail: valves@hydac.com