ALM-26234 BBU CPRI Interface Error

Network Element: BTS3900, BTS3900 WCDMA, BTS3900 LTE, BTS5900, BTS5900 WCDMA,
BTS5900 LTE

Alarm Description

This alarm is reported when the link between the BBU and the lower-level RF units or CXUs
malfunctions. This alarm is cleared when the link can function properly and remains
functional for a period of time (90s by default). The alarm filtering parameters can be set by
running the SET ALMFILTER command.

Alarm Attribute

Alarm ID Alarm Severity Alarm Type Applicable Introduced in


Mode Version...

26234 Major Fault G,U,L BTS3900: version


earlier than
V100R010C10

BTS3900
WCDMA: version
earlier than
V100R010C10

BTS3900 LTE:
version earlier
than
V100R010C10

BTS5900:
V100R013C00

BTS5900
Alarm ID Alarm Severity Alarm Type Applicable Introduced in
Mode Version...

WCDMA:
V100R013C00

BTS5900 LTE:
V100R013C00

Alarm Parameters

Name Meaning

Cabinet No. Cabinet number of the faulty port

Subrack No. Subrack number of the faulty port

Slot No. Slot number of the faulty port

Port No. Faulty port number

Board Type Type of the faulty board

Specific Problem Specific problem of the alarm (CPRIInterface Transmit Error,


CPRIInterface Reception Error, CPRI Port Blocked, CPRIInterface
Resource Conflict)

Impact on System
Alarm Severity Alarm Impact

Major In chain topology, the link for the lower-level RF units or CXUs is
disconnected and the services carried on the lower-level RF units are
interrupted. In CPRI MUX, the services of the peer mode are interrupted
when the local mode is a converging party and the faulty port provides
the convergence function.

In ring topology, the reliability of the links for the RF units decreases. In
this case, the standby link becomes the activated link for the lower-level
RF units, and the services are switched over to the standby link. If a hot
ring is used, the ongoing services are not affected. If a cold ring is used,
the ongoing services are interrupted temporarily.

In load sharing networks, all services over are switched to available links.
If the available transmission bandwidth of CPRI ports is less than the
bandwidth required by the services, the service specifications decrease.

In the trunk chain topology, all services are switched to available links. If
the available transmission bandwidth of CPRI ports is less than the
bandwidth required by the services, the service specifications decrease.

System Actions

In ring topology, the lower-level RF units automatically switch to the normal link.

Possible Causes

Cause Category Possible Causes

Data
 Data configuration is incorrect if a multimode base station
configuration
reports the alarm. As a result, the timing loop fails.

 The user has run a command that blocks the CPRI port.
Cause Category Possible Causes

 In a dual-mode network using the CPRI MUX feature, data from


the local end was converged to two baseband processing boards at
the peer end.

Software None

Hardware
 If the optical transmission is used, the optical module on the
port of the BBU connecting to the lower-level RF units or CXUs is
faulty.

 If the optical transmission is used, the interface board in the


BBU connecting to the lower-level RF units or CXUs is faulty.

 If the optical transmission is used, the optical module of the


lower-level RF unit or CXU connected to the BBU is faulty.

 If the optical transmission is used, the lower-level RF unit or


CXU connected to the BBU is faulty.

 If the electrical transmission is used, the cable between the


lower-level RF unit or CXU and BBU is faulty.

 In multimode configuration, the optical module on the BBU


interconnection port or the BBU interconnection cable is faulty.

Miscellaneous
 If the optical transmission is used, the optical module or
connector on the port of the BBU connecting to the lower-level RF
units or CXUs is not securely installed.

 If the optical transmission is used, the connector or the optical


module on the port of the lower-level RF unit or CXU connected to
the BBU is not securely installed.

 If the optical transmission is used, the fiber optic cable


Cause Category Possible Causes

between the lower-level RF unit or CXU and BBU is faulty.

 If the electrical transmission is used, the CPRI electrical cable


between the lower-level RF unit or CXU and BBU is not securely
installed.

Prerequisites

Obtain the product documents and read the following chapters or documents:

 Safety Information

 Initial Configuration Guide

Before handling this alarm, ensure the following:

 You have obtained the reference documentation related to this alarm.

 You can visit the site safely, if onsite operations are required.

Preprocessing

1. Check whether a correlated alarm is reported

Procedure Items to Be Confirmed Duration Impact


(min.)

Check for the root alarms on Check whether root alarms are 1 None

the U2000. reported on the U2000:

 26231 BBU Y=>The root alarms are reported. Clear

CPRI Optical Module or these root alarms.

Electrical Port Not Ready N=>The root alarms are not reported.
Continue handling this alarm.
Procedure Items to Be Confirmed Duration Impact
(min.)

 26272 Inter-
System RF Unit Parameter
Settings Conflict

 26314 Inter-
BBU Port Failure

 26240 BBU
Topology and
Configuration Mismatch

 26233 BBU
CPRI Optical Interface
Performance Degraded

 26230 BBU
CPRI Optical Module
Fault

 26232 BBU
Optical Module
Transmit/Receive Fault

 26237 RRU
Network Breakpoint

 26200 Board
Hardware Fault

 26506 RF
Unit Optical Interface
Performance Degraded
Procedure Items to Be Confirmed Duration Impact
(min.)

 26504 RF
Unit CPRI Interface Error

Configuration Handling

Procedure Items to Be Confirmed Duration Impact


(min.)

Note: If the faulty NE has The Main Topology window has been 1 None

been located on the topology, opened and the alarm NE is selected.


skip this step.

On the U2000, right-click the


alarm and choose "Locate in
Topology" from the shortcut
menu.

Procedure Items to Be Confirmed Duration Impact


(min.)

Check the icon of the NE that If a red disconnection flag is displayed 1 None
reported this alarm on the in the upper left corner of the NE icon,
Main Topology window. handle the NE disconnection. If there is
no such a flag, continue handling this
alarm.
Procedure Items to Be Confirmed Duration Impact
(min.)

On the Main Topology The MML Command window has been 1 None
window of the U2000, right- opened successfully.
click the NE selected in the
previous step and choose
MML Command from the
shortcut menu.

Procedure Items to Be Confirmed Duration Impact


(min.)

Run the MML command LST The settings of these parameters are 1 None

RRUCHAIN. In this step, do consistent with the configuration plan.


not specify any parameters. Check whether Topo Type is set to
Check the values of the TRUNK_CHAIN.
following parameters in the If Topo Type is set to TRUNK_CHAIN,
command output: an RMU is configured and there is no
[Chain No.] limitation for RMU working modes. Try

[Topo Type] other methods to clear the alarm.

[Head Cabinet No.] If Topo Type is set to TRUNK_CHAIN,

[Head Subrack No.] continue this step.

[Head Slot No.] Pay close attention to the information


in the following example of command
[Head Port No.]
output:
[CPRI Line Rate]
%%LST RRUCHAIN: RCN=0;%%
[User-Defined Rate
RETCODE = 0 Operation succeeded.
Negotiation Switch]
Chain No. = X
[Bit Rate Set]
Procedure Items to Be Confirmed Duration Impact
(min.)

Head Cabinet No. = X

Head Subrack No. = X

Head Slot No. = X

Head Port No. = X

CPRI Line Rate = X

User-Defined Rate Negotiation


Switch = X

Bit Rate Set = X

Procedure Items to Be Confirmed Duration Impact


(min.)

Run the MML command LST The setting of this parameter is 1 None

RRU. In this step, do not consistent with the configuration plan.


specify any parameters. Pay close attention to the information
Check the value of the [RF in the following example of command
Unit Working Mode] output:
parameter in the command %%LST RRU: CN=0, SRN=60, SN=0;%%
output. RETCODE = 0 Operation succeeded.

RF Unit Working Mode = X

Procedure Items to Be Confirmed Duration Impact


(min.)

Run the MML command LST The setting of this parameter is 1 None

SOFTWARE. In this step, do consistent with the configuration plan.


not specify any parameters. Pay close attention to the information
Procedure Items to Be Confirmed Duration Impact
(min.)

Check the value of the in the following example of command


[Software Version] parameter output:
in the command output. %%LST SOFTWARE: RCN=0;%%

RETCODE = 0 Operation succeeded.

Software Status = X

Procedure Items to Be Confirmed Duration Impact


(min.)

Contact the maintenance The version of the peer base station is 1 None
personnel at the peer end for recorded.
the version of the base
station.

Procedure Items to Be Confirmed Duration Impact


(min.)

Run the MML command LST Check whether [Administrative Status] 1 None

CPRIPORT. In this step, set the of the CPRI port is Blocked.


following parameters: Y=> The alarm is generated because of
[Cabinet No.]="Cabinet No."in the blocked port. Unblock the port to
the alarm parameters clear the alarm.

[Subrack No.]="Subrack N=>The alarm is generated because of


No."in the alarm parameters a reason other than a blocked port. Try

[Slot No.]="Slot No."in the other methods to clear the alarm.

alarm parameters Pay close attention to the information

[Port No.]="Port No."in the in the following example of command


Procedure Items to Be Confirmed Duration Impact
(min.)

alarm parameters output:

%%LST CPRIPORT:CN=0, SRN=0, SN=3,


OPTN=0; %%

RETCODE = 0 Operation succeeded.

Administrative Status = X

Procedure Items to Be Confirmed Duration Impact


(min.)

Run the MML command UBL Check whether this alarm is included in 1 None

CPRIPORT. In this step, set the the command output.


following parameters: Pay close attention to the information
[Cabinet No.] = "Cabinet in the following example of command
No."in the alarm parameters output:

[Subrack No.] = "Subrack %%UBLCPRIPORT:CN=0, SRN=0, SN=3,


No."in the alarm parameters OPTN=0; %%

[Slot No.] = "Slot No."in the RETCODE = 0 Operation succeeded.


alarm parameters

[Port No.] = "Port No."in the


alarm parameters.

Remote Handling
Expand All

1. Contact and assist onsite engineers

a. Display the Main Topology window

Procedure Items to Be Confirmed Duration Impact


(min.)

Note: If the faulty NE has The Main Topology window has been 1 None

been located on the topology, opened and the alarm NE is selected.


skip this step.

On the U2000, right-click the


alarm and choose "Locate in
Topology" from the shortcut
menu.

b. Confirm the connection status of NE


Procedure Items to Be Confirmed Duration Impact
(min.)

Check the icon of the NE that If a red disconnection flag is displayed 1 None
reported this alarm on the in the upper left corner of the NE icon,
Main Topology window. handle the NE disconnection. If there is
no such a flag, continue handling this
alarm.

c. Open the MML Command window

Procedure Items to Be Confirmed Duration Impact


(min.)

On the Main Topology The MML Command window has been 1 None
window of the U2000, right- opened successfully.
click the NE selected in the
previous step and choose
MML Command from the
shortcut menu.

d. Query the optical module information

Procedure Items to Be Confirmed Duration Impact


(min.)

Run the MML command DSP The settings of these parameters are 1 None

SFP to query the transmission consistent with the configuration plan.


mode of the optical module. Pay close attention to the information
In this step, set the following in the following example of command
parameters:
Procedure Items to Be Confirmed Duration Impact
(min.)

[Cabinet No.] = "Cabinet No." output:


in the alarm parameters %%DSP SFP: CN=0, SRN=0, SN=2,
[Subrack No.] = "Subrack No." PT=ALL, MODULEID=1;%%
in the alarm parameters RETCODE = 0 Operation succeeded.
[Slot No.] = "Slot No." in the Installed status = X
alarm parameters Transmission Mode = X
[Port Type] = ALL Wavelength(nm) = X
[SFP module number] = "Port SFP Module Type = X
No." in the alarm parameters

Check the values of the


following parameters in the
command output:

[Install Status]

[Transmission Mode]

[Wavelength(nm)]

[SFP Module Type]

Note: If you cannot obtain the


optical module information
with this command, you can
obtain the optical in the
network plan.

e. Open the Inventory Management tab page


Procedure Items to Be Confirmed Duration Impact
(min.)

Right-click the base station The Inventory Management tab page 1 None
related to the alarm and for the base station related to the alarm
choose "Inventory has been opened.
Management" from the
shortcut menu.

f. Obtain the inventory information

Procedure Items to Be Confirmed Duration Impact


(min.)

Choose "Physical Inventory > The Inventory Information tab page for 1 None
Rack", expand the nodes level the board related to the alarm has been
by level, and select the entry opened.
where [Cabinet No.], [Subrack
No.], and [Slot No.] are the
same as "Cabinet No.",
"Subrack No.", and "Slot No."
in the alarm parameters,
respectively.

g. Record the inventory information

Procedure Items to Be Confirmed Duration Impact


(min.)

Record the inventory The inventory information has been 1 None


information of the board and
Procedure Items to Be Confirmed Duration Impact
(min.)

provide this information to recorded.


on-site engineers.

h. Query inventory information about the optical module

Procedure Items to Be Confirmed Duration Impact


(min.)

Run the MML command DSP The recorded settings about these 1 None

ELABEL. In this step, set the parameters have been provided to the
following parameters: onsite engineers.

[Cabinet No.] = "Cabinet No." Pay close attention to the information


in the alarm parameters in the following example of command

[Subrack No.] = "Subrack No." output:


in the alarm parameters %%DSP ELABEL: DEVTYPE=SFP, CN=0,

[Slot No.] = "Slot No." in the SRN=0, SN=2, PT=0, PN=1;%%

alarm parameters RETCODE = 0 Operation succeeded.

[Port Type] = Actual port type BoardType = X

[Port No.] = "Port No." in the BarCode = X


alarm parameters Description = X
Check the values of the
following parameters in the
command output:

[Config Type]

[BarCode]

[Description]
Procedure Items to Be Confirmed Duration Impact
(min.)

Note: If you cannot obtain the


optical module information
with this command, you can
obtain the information in the
network plan.

i. Assist onsite engineers in rectifying the fault

Procedure Items to Be Confirmed Duration Impact


(min.)

Stay at the remote Onsite engineers can obtain assistance 1 None


maintenance center in case conveniently. The remote maintenance
onsite engineers need help. center is ready to perform necessary
operations when onsite engineers seek
help.

j. Check whether the alarm is cleared

Procedure Items to Be Confirmed Duration Impact


(min.)

Run the MML command LST Check whether this alarm is included in 1 None

ALMAF to query active alarms the command output:


with parameters set as Y=>This alarm is not cleared. Continue
follows: handling this alarm.
[Start Serial No.] = N=>This alarm is cleared. No further
"Equipment Alarm Serial action is required.
Procedure Items to Be Confirmed Duration Impact
(min.)

Number" in the alarm Pay close attention to the information


parameters in the following example of command

[End Serial No.] = "Equipment output:

Alarm Serial Number" in the %%LST ALMAF: SCSN=1, ECSN=1;%%


alarm parameters RETCODE = 0 Operation succeeded

No record exists

2. Collect information

a. Collect log information of the faulty board using the one-click method

Procedure Items to Be Confirmed Duration Impact


(min.)

Run the MML command The log has been successfully 15 For details

ULD FILE to use the one- uploaded to the specified directory. about the

click method to collect log This information must be provided to operation

information about the faulty technical support. impact, see

board. Pay close attention to the "Note" in

Input parameters: information in the following example the help

(using the faulty board of slot No.3 information


[Function Type] = "ALL"
as an example) of command output: of this
[Source File Type] =
command.
"BRDLOG" %%ULD FILE: FUNCTYPE=ALL,

[Cabinet No.] = "Cabinet SRCF=BRDLOG, CN=0, SRN=0,

No." in the alarm SN=3, DSTF="brdlog", MODE=IPV4,

parameters IP="192.168.90.163", USR="admin",


PWD="*****";%%
[Subrack No.] ="Subrack
No." in the alarm RETCODE = 0 Operation succeeded.
Procedure Items to Be Confirmed Duration Impact
(min.)

parameters Session ID = 65682

[Slot No.] = "Slot No." in (Number of results = 1)


the alarm parameters --- END
Other parameters are to be
set by the customer.

If the alarm parameters do


not contain cabinet No.,
subrack No., and slot No.,
collect one-click logs of the
main control board.

b. Collect logs of the active main control board using the one-click method
(If the main control board is faulty, skip this step.)

Procedure Items to Be Confirmed Duration Impact


(min.)

Run the MML command The command output contains the 15 For details

ULD FILE to use the one- following information: about the

click method to collect logs The log has been successfully operation

of the active main control uploaded to the specified directory. impact, see

board. This information must be provided to "Note" in

[Function Type] = "ALL" technical support. the help


information
[Source File Type] = Take the active main control board in
of this
"BRDLOG" slot No.7 as an example. Pay close
command.
[Cabinet No.] = "Cabinet attention to the following

No." of the active main information in a command output


Procedure Items to Be Confirmed Duration Impact
(min.)

control board example:

[Subrack No.] = "Subrack %%ULD FILE: FUNCTYPE=ALL,


No." of the active main SRCF=BRDLOG, CN=0, SRN=0,
control board SN=7, DSTF="brdlog", MODE=IPV4,

[Slot No.] = "Slot No." of IP="192.168.90.163", USR="admin",

the active main control PWD="*****";%%

board RETCODE = 0 Operation succeeded.

Other parameters are to be Session ID = 65682


set by the customer. (Number of results = 1)

--- END

c. Obtain the field information

Procedure Items to Be Confirmed Duration Impact


(min.)

Obtain a record and photos of The correct field information has been 1 None
the operations by the field provided to technical support.
engineers.

Onsite Preparation

Operation Procedure Items to Be Confirmed

Obtain the spare Obtain a USB flash drive, spare The inventory information about
parts optical modules, boards, fiber optic the spare parts is consistent with
cables, electrical cables, and RF that provided by the remote
Operation Procedure Items to Be Confirmed

units or CXUs based on the maintenance personnel. The


information provided by the remote maintenance personnel
remote maintenance personnel. confirm that the correct USB flash
The USB flash drive is provided by drive is provided.
the remote maintenance personnel
and is used for replacing the main
control board. The length and
working mode of the fiber optic
cables must be appropriate. Single-
mode fiber optic cables are yellow
and multi-mode fiber optic cables
are orange.

Prepare the Obtain the following tools: a flat- All the tools are ready and are in
tools head screwdriver (M3, M4, M5, good conditions.
M6), a Phillips screwdriver (M3, M4,
M5, M6), ESD gloves, a pen, paper,
fiber optic cables for loopback,
flange, an optical power meter,
dustfree cloth, alcohol, a high
pressure air gun, a hammer drill, a
vacuum cleaner, a heat gun, a
rubber mallet, a COAX crimping
tool, a wire stripper, a guarded
blade utility knife, cable cutter, an
adjustable wrench (size ≥ 32 mm),
a level, a torque screwdriver, a
torque wrench, a combination
wrench, a multimeter, a maker
Operation Procedure Items to Be Confirmed

(diameter ≤ 10 mm), and a


measuring tape.

Onsite Handling
Expand All
1. Check the CPRI electrical cable connections.Continue the operation according to
the flowchart based on the obtained information.

a. Remove and reinstall the CPRI electrical cable

Procedure Items to Be Confirmed Duration Impact


(min.)

Remove and reinstall the The CPRI electrical cable has been 1 Remote
CPRI electrical cable securely connected. maintenance
between the BBU and RF cannot be
unit/CXU. performed
on the RF
unit or CXU
connecting
to the CPRI
electrical
cables.

b. Replace the CPRI electrical cable

Procedure Items to Be Confirmed Duration Impact


(min.)

Replace the CPRI electrical The new CPRI electrical cable has 1 Remote
cable between the BBU and been securely connected. maintenance
RF unit/CXU. cannot be
performed
on the RF
unit or CXU
connecting
to the CPRI
Procedure Items to Be Confirmed Duration Impact
(min.)

electrical
cables.

c. Request remote maintenance engineers to check whether the alarm has


been cleared

Procedure Items to Be Confirmed Duration Impact


(min.)

Ask remote maintenance Remote maintenance engineers have 15 None


engineers to check whether been notified and they have confirmed
the alarm has been cleared. the status of the alarm.

2. Connect the RX and TX ports on the optical module of the BBU to perform a
loopback

a. Remove a fiber optic cable(Skip this step if the fiber optic cable cannot
be removed.)

Procedure Items to Be Confirmed Duration Impact


(min.)

Remove the fiber optic The indicator corresponding to the 1 Remote


cable from the target optical module is off. (CPRI indicator maintenance
optical module. of the UBRI or BBP other than the cannot be
UBBPei, XCI indicator of the UBBPei, performed
M port indicator of the UCIU, or on the RF
FE/GE port indicator of the unit or CXU
transmission board or main control connecting
Procedure Items to Be Confirmed Duration Impact
(min.)

board.) to the fiber


optic cables.

b. Clean a fiber optic cables splice

Procedure Items to Be Confirmed Duration Impact


(min.)

Remove the fiber optic cables The fiber optic cables splice has been 1 None
connected to the optical cleaned.
module and clean the end
face and cylinder face of the
ceramic ferrule using a dry
dust-free cloth that has been
dipped in alcohol. Then, clean
the ceramic ferrule again
using a dry dust-free cloth
that has not been dipped in
alcohol to ensure that the
ceramic ferrule is free from
fiber or scraps. Dry the end
face using a high-pressure air
gun if necessary.

c. Remove an optical module


Procedure Items to Be Confirmed Duration Impact
(min.)

Press the bulges on the The indicator corresponding to the 1 Remote


optical connectors, remove optical module is off. (CPRI indicator maintenance
the optical connectors from of the UBRI or BBP other than the cannot be
the faulty optical module, UBBPei, XCI indicator of the UBBPei, performed
lower the puller of the M port indicator of the UCIU, or on the RF
faulty optical module, hold FE/GE port indicator of the unit or CXU
the puller, and remove the transmission board or main control connecting
faulty optical module from board.) to the fiber
the port. optic cables.

d. Insert an optical module

Procedure Items to Be Confirmed Duration Impact


(min.)

Insert an optical module into When the optical module is securely 1 None
the corresponding slot. connected, the indicator corresponding
to the optical module is red. (CPRI
indicator of the UBRI or BBP other than
the UBBPei, XCI indicator of the UBBPei,
M port indicator of the UCIU, or FE/GE
port indicator of the transmission
board or main control board.)

e. Connect the RX and TX ports on the optical module of the BBU to


perform a loopback
Procedure Items to Be Confirmed Duration Impact
(min.)

Connect the TX and RX ports The fiber optic cables has been securely 5 None
on the optical module of the connected. During the loopback, the
BBU to perform a loopback. CPRI indicator corresponding to the
optical module is steady green, which
indicates that the optical module on
the BBU is functional.

f. Disconnect the RX and TX ports on the optical module

Procedure Items to Be Confirmed Duration Impact


(min.)

Disconnect the fiber optic The fiber optic cable has been securely 5 None
cable between the optical connected. The indicator is steady
module and flange plate, and green, which indicates that the fiber
restore the original fiber optic optic cable connection is functional.
cable connection.

g. Request remote maintenance engineers to check whether the alarm has


been cleared

Procedure Items to Be Confirmed Duration Impact


(min.)

Ask remote maintenance Remote maintenance engineers have 15 None


engineers to check whether been notified and they have confirmed
the alarm has been cleared. the status of the alarm.
3. Check the running status of the RF units or CXUs

a. Check the running status of the lower-level RF units or CXUs

Procedure Items to Be Confirmed Duration Impact


(min.)

Check the running status of The RUN indicator on the RF unit or 2 None
the lower-level RF unit or CXU CXU blinks (on for 1s and off for 1s),
onsite. If the RF unit or CXU is which indicates that the RF unit or CXU
faulty, power off and then is running properly.
power on the RF unit or CXU
onsite.

b. Request remote maintenance engineers to check whether the alarm has


been cleared

Procedure Items to Be Confirmed Duration Impact


(min.)

Ask remote maintenance Remote maintenance engineers have 15 None


engineers to check whether been notified and they have confirmed
the alarm has been cleared. the status of the alarm.

4. Connect the RX and TX ports on the optical moudle to perform a loopback from
the BBU to the RF unit or CXU

a. Connect the RX and TX ports on the optical module to perform a


loopback from the BBU to RF unit or CXU
Procedure Items to Be Confirmed Duration Impact
(min.)

Remove the fiber optic cable The fiber optic cable has been securely 5 None
from the optical module on connected.
the lower-level RF unit or CXU During the loopback, the CPRI indicator
onsite. Then, connect the TX corresponding to the optical module
and RX ports on the fiber on the BBU is steady green, which
module of the BBU with those indicates that the fiber optic cable
of a flange plate using the connection from the BBU to the RF unit
fiber optic cable to perform a or CXU is functional.
loopback (clean the fiber optic
cable slice before connecting
them).

b. Disconnect the RX and TX ports on the optical module

Procedure Items to Be Confirmed Duration Impact


(min.)

Disconnect the fiber optic The fiber optic cable has been securely 5 None
cable between the optical connected. The indicator is steady
module and flange plate, and green, which indicates that the fiber
restore the original fiber optic optic cable connection is functional.
cable connection.

c. Request remote maintenance engineers to check whether the alarm has


been cleared
Procedure Items to Be Confirmed Duration Impact
(min.)

Ask remote maintenance Remote maintenance engineers have 15 None


engineers to check whether been notified and they have confirmed
the alarm has been cleared. the status of the alarm.

5. Check fiber connections

a. Check fiber connections

Procedure Items to Be Confirmed Duration Impact


(min.)

Check the fiber optic cable Fiber optic cable connections meet the 5 None
connections between the BBU standard on cable bending and
and lower-level RF units or extrusion. The optical power at the
CXUs. Troubleshoot improper receive end meets requirements.
fiber optic cable connections,
such as cable bending or
deformation. Then, use an
optical power meter to
measure the optical power at
the receive end of the fiber
optic cable. If the optical
power is less than -40dBm,
signals are weak, and the fiber
optic cable is broken. If the
optical power is less than
-30dBm, signals are seriously
attenuated on the optical link
Procedure Items to Be Confirmed Duration Impact
(min.)

and the fiber optic cable must


be replaced.

b. Request remote maintenance engineers to check whether the alarm has


been cleared

Procedure Items to Be Confirmed Duration Impact


(min.)

Ask remote maintenance Remote maintenance engineers have 15 None


engineers to check whether been notified and they have confirmed
the alarm has been cleared. the status of the alarm.

6. Replace the optical module of the RF unit or CXU

a. Remove a fiber optic cable(Skip this step if the fiber optic cable cannot
be removed.)

Procedure Items to Be Confirmed Duration Impact


(min.)

Remove the fiber optic The indicator corresponding to the 1 Remote


cable from the target optical module is off. (CPRI indicator maintenance
optical module. of the UBRI or BBP other than the cannot be
UBBPei, XCI indicator of the UBBPei, performed
M port indicator of the UCIU, or on the RF
FE/GE port indicator of the unit or CXU
transmission board or main control connecting
board.) to the fiber
Procedure Items to Be Confirmed Duration Impact
(min.)

optic cables.

b. Replace an optical module

Procedure Items to Be Confirmed Duration Impact


(min.)

Remove the optical module When the optical module is securely 1 The cell

and then insert the spare connected, the indicator becomes

optical module into the corresponding to the optical module out of

original port. is red. (CPRI indicator of the UBRI or service.

To remove an optical BBP other than the UBBPei, XCI Remote

module, do as follows: indicator of the UBBPei, M port maintenance

Press the bulges on the indicator of the UCIU, or FE/GE port cannot be

optical connectors, remove indicator of the transmission board performed

the optical connectors from or main control board.) on the RF

the optical module, lower unit or CXU

the puller of the faulty connecting

optical module, hold the to the fiber

puller, and remove the optic cables.

faulty optical module from


the port.

c. Insert a fiber optic cable


Procedure Items to Be Confirmed Duration Impact
(min.)

Insert the fiber optic cable After the fiber optic cable is properly 1 None

into the target optical connected, the indicator corresponding


module. to the optical module is steady green,

Note : Ensure that the model which indicates that the fiber optic

of the optical module or fiber cable connection is functional.

optic cable is consistent with A red indicator indicates that the fiber
that in the engineering plan. optic cable connection is faulty. (CPRI
indicator of the UBRI or BBP other than
the UBBPei, XCI indicator of the UBBPei,
M port indicator of the UCIU, or FE/GE
port indicator of the transmission
board or main control board.)

d. Request remote maintenance engineers to check whether the alarm has


been cleared

Procedure Items to Be Confirmed Duration Impact


(min.)

Ask remote maintenance Remote maintenance engineers have 15 None


engineers to check whether been notified and they have confirmed
the alarm has been cleared. the status of the alarm.

7. Replace the RF unit or CXU

a. Request remote maintenance engineers to block a board


Procedure Items to Be Confirmed Duration Impact
(min.)

Request remote maintenance The board has been blocked. 5 The cell
engineers to block the board becomes
with the slot No., subrack out of
No., and cabinet No. service.
specified in the alarm
parameters.

b. Power off the RF unit or CXU

Procedure Items to Be Confirmed Duration Impact


(min.)

Remove the power cable After the power cable is removed, all 5 The cell
from the RF unit or CXU. the indicators on the RF unit or CXU becomes
are off. out of
service.
Remote
maintenance
cannot be
performed
on the RF
unit or CXU
connecting
to the fiber
optic cables.

c. Record the cable connections


Procedure Items to Be Confirmed Duration Impact
(min.)

Record the cable connections The cable connections to the RF unit or 1 None
to the RF unit or CXU. CXU have been recorded and labeled.

d. Remove all the cables connected to the RF unit or CXU

Procedure Items to Be Confirmed Duration Impact


(min.)

Remove the power cables, All the cables have been removed 5 The cell
fiber optic cables, jumper, from the RF unit or CXU. becomes
and interconnection cable out of
connected to the RF unit or service.
CXU. Remote
maintenance
cannot be
performed
on the RF
unit or CXU
connecting
to the fiber
optic cables.

e. Remove the RF unit or CXU

Procedure Items to Be Confirmed Duration Impact


(min.)

Remove the RF unit or CXU by The RF unit or CXU has been removed. 5 None
Procedure Items to Be Confirmed Duration Impact
(min.)

following the operations in


Site Maintenance Guide.

f. Install an RF unit or CXU

Procedure Items to Be Confirmed Duration Impact


(min.)

Install the RF unit or CXU by The RF unit or CXU has been installed 5 None
following the operations in securely.
Site Maintenance Guide.

g. Install cables to an RF unit or CXU

Procedure Items to Be Confirmed Duration Impact


(min.)

Install cables to the RF unit or Cables are securely installed to the RF 5 None
CXU according to the unit or CXU.
recorded connections and by
following the operations in
Site Maintenance Guide.

h. Power on an RF unit or CXU


Procedure Items to Be Confirmed Duration Impact
(min.)

Install the power cable to the All the indicators on the RF unit or CXU 5 None
RF unit or CXU, and then are on.
power on the RF unit or CXU.

i. Request remote maintenance engineers to unblock a board

Procedure Items to Be Confirmed Duration Impact


(min.)

Request remote maintenance The board has been unblocked. 5 None


engineers to unblock the
board with the slot No.,
subrack No., and cabinet No.
specified in the alarm
parameters.

j. Request remote maintenance engineers to check whether the alarm has


been cleared

Procedure Items to Be Confirmed Duration Impact


(min.)

Ask remote maintenance Remote maintenance engineers have 15 None


engineers to check whether been notified and they have confirmed
the alarm has been cleared. the status of the alarm.

8. Reinstall the original RF unit or CXU

a. Request remote maintenance engineers to block a board


Procedure Items to Be Confirmed Duration Impact
(min.)

Request remote maintenance The board has been blocked. 5 The cell
engineers to block the board becomes
with the slot No., subrack out of
No., and cabinet No. service.
specified in the alarm
parameters.

b. Power off the RF unit or CXU

Procedure Items to Be Confirmed Duration Impact


(min.)

Remove the power cable After the power cable is removed, all 5 The cell
from the RF unit or CXU. the indicators on the RF unit or CXU becomes
are off. out of
service.
Remote
maintenance
cannot be
performed
on the RF
unit or CXU
connecting
to the fiber
optic cables.

c. Record the cable connections


Procedure Items to Be Confirmed Duration Impact
(min.)

Record the cable connections The cable connections to the RF unit or 1 None
to the RF unit or CXU. CXU have been recorded and labeled.

d. Remove all the cables connected to the RF unit or CXU

Procedure Items to Be Confirmed Duration Impact


(min.)

Remove the power cables, All the cables have been removed 5 The cell
fiber optic cables, jumper, from the RF unit or CXU. becomes
and interconnection cable out of
connected to the RF unit or service.
CXU. Remote
maintenance
cannot be
performed
on the RF
unit or CXU
connecting
to the fiber
optic cables.

e. Remove the RF unit or CXU

Procedure Items to Be Confirmed Duration Impact


(min.)

Remove the RF unit or CXU by The RF unit or CXU has been removed. 5 None
Procedure Items to Be Confirmed Duration Impact
(min.)

following the operations in


Site Maintenance Guide.

f. Install an RF unit or CXU

Procedure Items to Be Confirmed Duration Impact


(min.)

Install the RF unit or CXU by The RF unit or CXU has been installed 5 None
following the operations in securely.
Site Maintenance Guide.

g. Install cables to an RF unit or CXU

Procedure Items to Be Confirmed Duration Impact


(min.)

Install cables to the RF unit or Cables are securely installed to the RF 5 None
CXU according to the unit or CXU.
recorded connections and by
following the operations in
Site Maintenance Guide.

h. Power on an RF unit or CXU


Procedure Items to Be Confirmed Duration Impact
(min.)

Install the power cable to the All the indicators on the RF unit or CXU 5 None
RF unit or CXU, and then are on.
power on the RF unit or CXU.

i. Request remote maintenance engineers to unblock a board

Procedure Items to Be Confirmed Duration Impact


(min.)

Request remote maintenance The board has been unblocked. 5 None


engineers to unblock the
board with the slot No.,
subrack No., and cabinet No.
specified in the alarm
parameters.

9. Replace the optical module of the BBU

a. Remove a fiber optic cable(Skip this step if the fiber optic cable cannot
be removed.)

Procedure Items to Be Confirmed Duration Impact


(min.)

Remove the fiber optic The indicator corresponding to the 1 Remote


cable from the target optical module is off. (CPRI indicator maintenance
optical module. of the UBRI or BBP other than the cannot be
UBBPei, XCI indicator of the UBBPei, performed
M port indicator of the UCIU, or on the RF
Procedure Items to Be Confirmed Duration Impact
(min.)

FE/GE port indicator of the unit or CXU


transmission board or main control connecting
board.) to the fiber
optic cables.

b. Replace an optical module

Procedure Items to Be Confirmed Duration Impact


(min.)

Remove the optical module When the optical module is securely 1 The cell

and then insert the spare connected, the indicator becomes

optical module into the corresponding to the optical module out of

original port. is red. (CPRI indicator of the UBRI or service.

To remove an optical BBP other than the UBBPei, XCI Remote

module, do as follows: indicator of the UBBPei, M port maintenance

Press the bulges on the indicator of the UCIU, or FE/GE port cannot be

optical connectors, remove indicator of the transmission board performed

the optical connectors from or main control board.) on the RF

the optical module, lower unit or CXU

the puller of the faulty connecting

optical module, hold the to the fiber

puller, and remove the optic cables.

faulty optical module from


the port.

c. Insert a fiber optic cable


Procedure Items to Be Confirmed Duration Impact
(min.)

Insert the fiber optic cable After the fiber optic cable is properly 1 None

into the target optical connected, the indicator corresponding


module. to the optical module is steady green,

Note : Ensure that the model which indicates that the fiber optic

of the optical module or fiber cable connection is functional.

optic cable is consistent with A red indicator indicates that the fiber
that in the engineering plan. optic cable connection is faulty. (CPRI
indicator of the UBRI or BBP other than
the UBBPei, XCI indicator of the UBBPei,
M port indicator of the UCIU, or FE/GE
port indicator of the transmission
board or main control board.)

d. Request remote maintenance engineers to check whether the alarm has


been cleared

Procedure Items to Be Confirmed Duration Impact


(min.)

Ask remote maintenance Remote maintenance engineers have 15 None


engineers to check whether been notified and they have confirmed
the alarm has been cleared. the status of the alarm.

10. Reinstall the board

a. Remove a board
Procedure Items to Be Confirmed Duration Impact
(min.)

Remove the two panel All the indicators on the board are off. 1 Users
screws, and then remove the fail to
board from the subrack. access
the
network.

b. Insert the board

Procedure Items to Be Confirmed Duration Impact


(min.)

Insert the board into the After 5 minutes, the RUN indicator on 1 None
subrack, and tighten the the board blinks (on for 1s and off for
screws on the board. 1s), and the ALM indicator is off, which
indicates that the board runs properly.

c. Request remote maintenance engineers to check whether the alarm has


been cleared

Procedure Items to Be Confirmed Duration Impact


(min.)

Ask remote maintenance Remote maintenance engineers have 15 None


engineers to check whether been notified and they have confirmed
the alarm has been cleared. the status of the alarm.

11. Reset the base station

a. Reset the base station


Procedure Items to Be Confirmed Duration Impact
(min.)

Note: Resetting a base The command has been successfully 3 For details

station interrupts services of executed if a success indication is about the

the base station. Therefore, included in the command output. operation

reset the base station in low Note: impact, see

traffic hours, for example, at Resetting a main control board or a "Note" in

midnight. the help


CCU takes 3 minutes.
Run the MML command information
Resetting other board stakes 1
RST BTSNODE. of this
minute.
command.
Pay close attention to the
information in the following example
of command output:

%%RST BTSNODE:;%%

RETCODE = 0 Operation succeeded.

b. Check whether the alarm is cleared

Procedure Items to Be Confirmed Duration Impact


(min.)

Run the MML command LST Check whether this alarm is included in 1 None

ALMAF to query active alarms the command output:


with parameters set as Y=>This alarm is not cleared. Continue
follows: handling this alarm.
[Start Serial No.] = N=>This alarm is cleared. No further
"Equipment Alarm Serial action is required.
Number" in the alarm Pay close attention to the information
parameters in the following example of command
Procedure Items to Be Confirmed Duration Impact
(min.)

[End Serial No.] = "Equipment output:


Alarm Serial Number" in the %%LST ALMAF: SCSN=1, ECSN=1;%%
alarm parameters RETCODE = 0 Operation succeeded

No record exists

12. Replace the board

a. Record cable connections to a board

Procedure Items to Be Confirmed Duration Impact


(min.)

Record all cable connections Cable connections to the board are 1 None
to a board. correctly recorded.

b. Replace a board

Procedure Items to Be Confirmed Duration Impact


(min.)

Remove the faulty board, The new board is properly inserted 1 Users
insert a new board into the into the slot housing the faulty board. fail to
slot housing the faulty board, After 5 minutes, the RUN indicator on access
and tighten the screws on the the board blinks (on for 1s and off for the
new board to 0.6N·m. 1s) and the ALM indicator is off, which network.
indicates that the board runs properly.

c. Reconnect cables to a board


Procedure Items to Be Confirmed Duration Impact
(min.)

Reconnect cables to the board The current cable connections are 1 None
according to the recorded consistent with the original cable
cable connections. connections.

d. Check the status

Procedure Items to Be Confirmed Duration Impact


(min.)

Wait 5 minutes, and then Ensure that the RUN indicator is on for 5 None
check the status of RUN and 1s and off for 1s and that the ALM
ALM indicators on target indicator is steady off.
boards.

e. Request remote maintenance engineers to check whether the alarm has


been cleared

Procedure Items to Be Confirmed Duration Impact


(min.)

Ask remote maintenance Remote maintenance engineers have 15 None


engineers to check whether been notified and they have confirmed
the alarm has been cleared. the status of the alarm.

13. Replace the BLADEBBU

a. Record cable connections to a board


Procedure Items to Be Confirmed Duration Impact
(min.)

Record all cable connections Cable connections to the board are 1 None
to a board. correctly recorded.

b. Replace a BLADEBBU

Procedure Items to Be Confirmed Duration Impact


(min.)

Remove the faulty After 5 minutes, the RUN indicator on 1 Users


BLADEBBU, install a new the board blinks (on for 1s and off for fail to
BLADEBBU, and tighten the 1s), and the ALM indicator is off, which access
screws. indicates that the board runs properly. the
network.

c. Reconnect cables to a board

Procedure Items to Be Confirmed Duration Impact


(min.)

Reconnect cables to the board The current cable connections are 1 None
according to the recorded consistent with the original cable
cable connections. connections.

14. Activate base station software

a. Activate the NE using a USB flash drive


Procedure Items to Be Confirmed Duration Impact
(min.)

During the normal operation The NE analyzes the general 30 The NE


of the NE, insert the USB configuration file, loads the certificate becomes
flash drive into the USB port file, and downloads and activates the out of
on the main control board. base station software and data service.

configuration files.

When the NE is automatically


detecting the USB flash drive, the
indicator on the USB flash drive is
steady on, and the RUN indicator on
the main control board blinks (on for
1s and off for 1s).

When the NEis downloading files from


the USB flash drive, the indicator on
the USB flash drive blinks and the RUN
indicator on the main control board
blinks (on for 0.125s and off for
0.125s).

When the NEis activating the software


and data configuration files, the
indicator on the USB flash drive is
steady on and the RUN indicator on
the main control board blinks (on for
0.125s and off for 0.125s).

After the NE is activated, the indicator


on the USB flash drive is steady on and
the RUN indicator on the main control
board blinks (on for 1s and off for 1s).
b. Request remote maintenance engineers to check whether the alarm has
been cleared

Procedure Items to Be Confirmed Duration Impact


(min.)

Ask remote maintenance Remote maintenance engineers have 15 None


engineers to check whether been notified and they have confirmed
the alarm has been cleared. the status of the alarm.

15. Reinstall the original board

a. Request remote maintenance engineers to block a board

Procedure Items to Be Confirmed Duration Impact


(min.)

Request remote maintenance The board has been blocked. 5 The cell
engineers to block the board becomes
with the slot No., subrack out of
No., and cabinet No. service.
specified in the alarm
parameters.

b. Reinstall the original board

Procedure Items to Be Confirmed Duration Impact


(min.)

Reinstall the original board The board has been securely 1 None
and tighten the screws. reinstalled.

After 5 minutes, the RUN indicator on


Procedure Items to Be Confirmed Duration Impact
(min.)

the board blinks (on for 1s and off for


1s), and the ALM indicator is off, which
indicates that the board runs properly.

c. Reconnect cables to a board

Procedure Items to Be Confirmed Duration Impact


(min.)

Reconnect cables to the board The current cable connections are 1 None
according to the recorded consistent with the original cable
cable connections. connections.

d. Request remote maintenance engineers to unblock a board

Procedure Items to Be Confirmed Duration Impact


(min.)

Request remote maintenance The board has been unblocked. 5 None


engineers to unblock the
board with the slot No.,
subrack No., and cabinet No.
specified in the alarm
parameters.

16. Reinstall the original BLADEBBU

a. Reinstall the original BLADEBBU


Procedure Items to Be Confirmed Duration Impact
(min.)

Reinstall the original After 5 minutes, the RUN indicator on 1 None


BLADEBBU and tighten the the board blinks (on for 1s and off for
screws. 1s), and the ALM indicator is off, which
indicates that the board runs properly.

b. Reconnect cables to a board

Procedure Items to Be Confirmed Duration Impact


(min.)

Reconnect cables to the board The current cable connections are 1 None
according to the recorded consistent with the original cable
cable connections. connections.

17. Reinstall the board

a. Remove a board

Procedure Items to Be Confirmed Duration Impact


(min.)

Remove the two panel All the indicators on the board are off. 1 Users
screws, and then remove the fail to
board from the subrack. access
the
network.

b. Insert the board


Procedure Items to Be Confirmed Duration Impact
(min.)

Insert the board into the After 5 minutes, the RUN indicator on 1 None
subrack, and tighten the the board blinks (on for 1s and off for
screws on the board. 1s), and the ALM indicator is off, which
indicates that the board runs properly.

c. Request remote maintenance engineers to check whether the alarm has


been cleared

Procedure Items to Be Confirmed Duration Impact


(min.)

Ask remote maintenance Remote maintenance engineers have 15 None


engineers to check whether been notified and they have confirmed
the alarm has been cleared. the status of the alarm.

18. Reset the base station

a. Reset the base station

Procedure Items to Be Confirmed Duration Impact


(min.)

Note: Resetting a base The command has been successfully 3 For details

station interrupts services of executed if a success indication is about the

the base station. Therefore, included in the command output. operation

reset the base station in low Note: impact, see

traffic hours, for example, at Resetting a main control board or a "Note" in

midnight. the help


CCU takes 3 minutes.
information
Procedure Items to Be Confirmed Duration Impact
(min.)

Run the MML command Resetting other board stakes 1 of this

RST BTSNODE. minute. command.

Pay close attention to the


information in the following example
of command output:

%%RST BTSNODE:;%%

RETCODE = 0 Operation succeeded.

b. Check whether the alarm is cleared

Procedure Items to Be Confirmed Duration Impact


(min.)

Run the MML command LST Check whether this alarm is included in 1 None

ALMAF to query active alarms the command output:


with parameters set as Y=>This alarm is not cleared. Continue
follows: handling this alarm.
[Start Serial No.] = N=>This alarm is cleared. No further
"Equipment Alarm Serial action is required.
Number" in the alarm Pay close attention to the information
parameters in the following example of command
[End Serial No.] = "Equipment output:
Alarm Serial Number" in the %%LST ALMAF: SCSN=1, ECSN=1;%%
alarm parameters
RETCODE = 0 Operation succeeded

No record exists

19. Replace the board


a. Record cable connections to a board

Procedure Items to Be Confirmed Duration Impact


(min.)

Record all cable connections Cable connections to the board are 1 None
to a board. correctly recorded.

b. Replace a board

Procedure Items to Be Confirmed Duration Impact


(min.)

Remove the faulty board, The new board is properly inserted 1 Users
insert a new board into the into the slot housing the faulty board. fail to
slot housing the faulty board, After 5 minutes, the RUN indicator on access
and tighten the screws on the the board blinks (on for 1s and off for the
new board to 0.6N·m. 1s) and the ALM indicator is off, which network.
indicates that the board runs properly.

c. Reconnect cables to a board

Procedure Items to Be Confirmed Duration Impact


(min.)

Reconnect cables to the board The current cable connections are 1 None
according to the recorded consistent with the original cable
cable connections. connections.

d. Check the status


Procedure Items to Be Confirmed Duration Impact
(min.)

Wait 5 minutes, and then Ensure that the RUN indicator is on for 5 None
check the status of RUN and 1s and off for 1s and that the ALM
ALM indicators on target indicator is steady off.
boards.

e. Request remote maintenance engineers to check whether the alarm has


been cleared

Procedure Items to Be Confirmed Duration Impact


(min.)

Ask remote maintenance Remote maintenance engineers have 15 None


engineers to check whether been notified and they have confirmed
the alarm has been cleared. the status of the alarm.

20. Replace the BLADEBBU

a. Record cable connections to a board

Procedure Items to Be Confirmed Duration Impact


(min.)

Record all cable connections Cable connections to the board are 1 None
to a board. correctly recorded.

b. Replace a BLADEBBU
Procedure Items to Be Confirmed Duration Impact
(min.)

Remove the faulty After 5 minutes, the RUN indicator on 1 Users


BLADEBBU, install a new the board blinks (on for 1s and off for fail to
BLADEBBU, and tighten the 1s), and the ALM indicator is off, which access
screws. indicates that the board runs properly. the
network.

c. Reconnect cables to a board

Procedure Items to Be Confirmed Duration Impact


(min.)

Reconnect cables to the board The current cable connections are 1 None
according to the recorded consistent with the original cable
cable connections. connections.

21. Reinstall the original board

a. Request remote maintenance engineers to block a board

Procedure Items to Be Confirmed Duration Impact


(min.)

Request remote maintenance The board has been blocked. 5 The cell
engineers to block the board becomes
with the slot No., subrack out of
No., and cabinet No. service.
specified in the alarm
parameters.
b. Reinstall the original board

Procedure Items to Be Confirmed Duration Impact


(min.)

Reinstall the original board The board has been securely 1 None
and tighten the screws. reinstalled.

After 5 minutes, the RUN indicator on


the board blinks (on for 1s and off for
1s), and the ALM indicator is off, which
indicates that the board runs properly.

c. Reconnect cables to a board

Procedure Items to Be Confirmed Duration Impact


(min.)

Reconnect cables to the board The current cable connections are 1 None
according to the recorded consistent with the original cable
cable connections. connections.

d. Request remote maintenance engineers to unblock a board

Procedure Items to Be Confirmed Duration Impact


(min.)

Request remote maintenance The board has been unblocked. 5 None


engineers to unblock the
board with the slot No.,
subrack No., and cabinet No.
specified in the alarm
Procedure Items to Be Confirmed Duration Impact
(min.)

parameters.

22. Reinstall the original BLADEBBU

a. Reinstall the original BLADEBBU

Procedure Items to Be Confirmed Duration Impact


(min.)

Reinstall the original After 5 minutes, the RUN indicator on 1 None


BLADEBBU and tighten the the board blinks (on for 1s and off for
screws. 1s), and the ALM indicator is off, which
indicates that the board runs properly.

b. Reconnect cables to a board

Procedure Items to Be Confirmed Duration Impact


(min.)

Reconnect cables to the board The current cable connections are 1 None
according to the recorded consistent with the original cable
cable connections. connections.

23. Check the running status of the RF units or CXUs

a. Check the running status of the lower-level RF units or CXUs


Procedure Items to Be Confirmed Duration Impact
(min.)

Check the running status of The RUN indicator on the RF unit or 2 None
the lower-level RF unit or CXU CXU blinks (on for 1s and off for 1s),
onsite. If the RF unit or CXU is which indicates that the RF unit or CXU
faulty, power off and then is running properly.
power on the RF unit or CXU
onsite.

b. Request remote maintenance engineers to check whether the alarm has


been cleared

Procedure Items to Be Confirmed Duration Impact


(min.)

Ask remote maintenance Remote maintenance engineers have 15 None


engineers to check whether been notified and they have confirmed
the alarm has been cleared. the status of the alarm.

24. Replace the RF unit or CXU

a. Request remote maintenance engineers to block a board

Procedure Items to Be Confirmed Duration Impact


(min.)

Request remote maintenance The board has been blocked. 5 The cell
engineers to block the board becomes
with the slot No., subrack out of
No., and cabinet No. service.
specified in the alarm
Procedure Items to Be Confirmed Duration Impact
(min.)

parameters.

b. Power off the RF unit or CXU

Procedure Items to Be Confirmed Duration Impact


(min.)

Remove the power cable After the power cable is removed, all 5 The cell
from the RF unit or CXU. the indicators on the RF unit or CXU becomes
are off. out of
service.
Remote
maintenance
cannot be
performed
on the RF
unit or CXU
connecting
to the fiber
optic cables.

c. Record the cable connections


Procedure Items to Be Confirmed Duration Impact
(min.)

Record the cable connections The cable connections to the RF unit or 1 None
to the RF unit or CXU. CXU have been recorded and labeled.

d. Remove all the cables connected to the RF unit or CXU

Procedure Items to Be Confirmed Duration Impact


(min.)

Remove the power cables, All the cables have been removed 5 The cell
fiber optic cables, jumper, from the RF unit or CXU. becomes
and interconnection cable out of
connected to the RF unit or service.
CXU. Remote
maintenance
cannot be
performed
on the RF
unit or CXU
connecting
to the fiber
optic cables.

e. Remove the RF unit or CXU

Procedure Items to Be Confirmed Duration Impact


(min.)

Remove the RF unit or CXU by The RF unit or CXU has been removed. 5 None
Procedure Items to Be Confirmed Duration Impact
(min.)

following the operations in


Site Maintenance Guide.

f. Install an RF unit or CXU

Procedure Items to Be Confirmed Duration Impact


(min.)

Install the RF unit or CXU by The RF unit or CXU has been installed 5 None
following the operations in securely.
Site Maintenance Guide.

g. Install cables to an RF unit or CXU

Procedure Items to Be Confirmed Duration Impact


(min.)

Install cables to the RF unit or Cables are securely installed to the RF 5 None
CXU according to the unit or CXU.
recorded connections and by
following the operations in
Site Maintenance Guide.

h. Power on an RF unit or CXU


Procedure Items to Be Confirmed Duration Impact
(min.)

Install the power cable to the All the indicators on the RF unit or CXU 5 None
RF unit or CXU, and then are on.
power on the RF unit or CXU.

i. Request remote maintenance engineers to unblock a board

Procedure Items to Be Confirmed Duration Impact


(min.)

Request remote maintenance The board has been unblocked. 5 None


engineers to unblock the
board with the slot No.,
subrack No., and cabinet No.
specified in the alarm
parameters.

j. Request remote maintenance engineers to check whether the alarm has


been cleared

Procedure Items to Be Confirmed Duration Impact


(min.)

Ask remote maintenance Remote maintenance engineers have 15 None


engineers to check whether been notified and they have confirmed
the alarm has been cleared. the status of the alarm.

25. Reinstall the original RF unit or CXU

a. Request remote maintenance engineers to block a board


Procedure Items to Be Confirmed Duration Impact
(min.)

Request remote maintenance The board has been blocked. 5 The cell
engineers to block the board becomes
with the slot No., subrack out of
No., and cabinet No. service.
specified in the alarm
parameters.

b. Power off the RF unit or CXU

Procedure Items to Be Confirmed Duration Impact


(min.)

Remove the power cable After the power cable is removed, all 5 The cell
from the RF unit or CXU. the indicators on the RF unit or CXU becomes
are off. out of
service.
Remote
maintenance
cannot be
performed
on the RF
unit or CXU
connecting
to the fiber
optic cables.

c. Record the cable connections


Procedure Items to Be Confirmed Duration Impact
(min.)

Record the cable connections The cable connections to the RF unit or 1 None
to the RF unit or CXU. CXU have been recorded and labeled.

d. Remove all the cables connected to the RF unit or CXU

Procedure Items to Be Confirmed Duration Impact


(min.)

Remove the power cables, All the cables have been removed 5 The cell
fiber optic cables, jumper, from the RF unit or CXU. becomes
and interconnection cable out of
connected to the RF unit or service.
CXU. Remote
maintenance
cannot be
performed
on the RF
unit or CXU
connecting
to the fiber
optic cables.

e. Remove the RF unit or CXU

Procedure Items to Be Confirmed Duration Impact


(min.)

Remove the RF unit or CXU by The RF unit or CXU has been removed. 5 None
Procedure Items to Be Confirmed Duration Impact
(min.)

following the operations in


Site Maintenance Guide.

f. Install an RF unit or CXU

Procedure Items to Be Confirmed Duration Impact


(min.)

Install the RF unit or CXU by The RF unit or CXU has been installed 5 None
following the operations in securely.
Site Maintenance Guide.

g. Install cables to an RF unit or CXU

Procedure Items to Be Confirmed Duration Impact


(min.)

Install cables to the RF unit or Cables are securely installed to the RF 5 None
CXU according to the unit or CXU.
recorded connections and by
following the operations in
Site Maintenance Guide.

h. Power on an RF unit or CXU


Procedure Items to Be Confirmed Duration Impact
(min.)

Install the power cable to the All the indicators on the RF unit or CXU 5 None
RF unit or CXU, and then are on.
power on the RF unit or CXU.

i. Request remote maintenance engineers to unblock a board

Procedure Items to Be Confirmed Duration Impact


(min.)

Request remote maintenance The board has been unblocked. 5 None


engineers to unblock the
board with the slot No.,
subrack No., and cabinet No.
specified in the alarm
parameters.

26. Notify the remote maintenance center

Procedure Items to Be Confirmed Duration Impact


(min.)

Notify the personnel at the The operations required by the remote 1 None
remote maintenance center maintenance center have been
that onsite processing is successfully performed. The remote
complete, and ask them to maintenance center has confirmed that
confirm whether the alarm onsite processing is complete and
has been cleared and whether onsite engineers can leave.
the equipment is running
Procedure Items to Be Confirmed Duration Impact
(min.)

properly. Perform the


operations required by the
remote maintenance center.

27. Collect field information

a. Collect onsite information

Procedure Items to Be Confirmed Duration Impact


(min.)

Record the onsite operation The field information is correctly - None


process in detail, and take a collected and provided to the remote
picture of all devices and a maintenance center.
picture of each device used.

b. Contact the remote maintenance center

Procedure Items to Be Confirmed Duration Impact


(min.)

Request remote maintenance The remote maintenance engineers 1 None


engineers to confirm the have confirmed the failure and the site
failure and provide the site information has been provided.
information for them.

Related Information
None.