RT310 / RT310TX Thermostat RXRT510 Receiver The DIP Switches can be found on the rear of your thermostat.
Thermostat
Thermostat
RT310TX
RXRT510
RT310TX
Receiver
2 4 L № 2, the DIP switch №
switch on DIP switch № 2,
N
Thermostat
Thermostat
RXRT510
COM
1 is functional. You can choose
the DIP switch № 1 is
Receiver
RT310TX
RXRT510
RT310TX
Receiver
L
AC 230 V
COM the Cycles Per Hour between not functional. The
AC 230 V
a NO
lower comfort level (6CPH) temperature accuracy of
5 6
NO and a higher comfort level your thermostat is set to
7 8 (9CPH). N L ± 0.25 °C.
N L
1. Turn on the LCD backlight 5. When in Manual Mode, RT310 Wiring diagram AC 230 V
2. Turn On/Off the Frost Mode ON will turn the boiler on. L
AC 230 V
3. Increase button 6. When in Manual Mode, L
Thermostat
4. Decrease button OFF will turn the boiler off.
RT310
7. Receiver operates in automatic mode
Thermostat
RT310
according to the thermostat MAX
3 (1) A
Thermostat
8. Receiver output is controlled MAX
RT310
by the On/Off slide switch. 3 (1) A
Thermostat
NO
COM
NC
RT310
NO
COM
NC
NO
COM
NC
LCD Icon description OR M
NO
COM
NC
OR M
Quick Guide 1. Heating Mode ON
N
1 5 N
2. Frost Protection Mode ON
2 6 3. RF signal indicator (only in RT310RF)
3 4. Low battery status
5. Temperature unit RT310RF Wiring diagram
Introduction 4
6. Room / setpoint temperature
RT310 / RT310TX / RT310RF is a digital room thermosat used to control room temperature. Device
launching heating system by shorting terminal blocks, simultaneously informing the action and Note: If you are using the RT310RF pack, the pairing between the thermostat and the receiver
showing this information on the LCD display. Before use please read this manual carefully. Use only is already done.
AA 1.5 V alkaline batteries in the thermostat. Place the batteries into the battery slot located under the
cover. Do not use rechargeable batteries.
Product compliance
RT310 Terminals description
This product complies with the essential requirements and other relevant provisions of the following EU Directives:
EMC 2014/30/EU, LVD 2014/35/EU, RED 2014/53/EU and RoHS 2011/65/EU. Full text of the EU Declaration of Terminal Description
Conformity is available on www.saluslegal.com 1 - COM Common Terminal N
Thermostat
Thermostat
868.0-868.6MHz; <13dBm
RT310TX
RXRT510
RT310TX
Receiver
2 - NC Switched Live OFF L
COM
AC 230 V
3 - NO Switched Live ON
Safety Information NO
Use in accordance to national and EU regulations. Use the device as intended, keeping it in dry condition.
Product for indoor use only. Installation must be carried out by a qualified person in accordance to N L
national and EU regulations.
Technical specification
AC 230 V
RT310 RT310TX
RXRT510 Receiver terminals description L
Thermostat
N
Terminal Description N
Thermostat
Thermostat
RXRT510
Receiver supply - 230 V AC
RT310
Receiver
RT310TX
L
RXRT510
RT310TX
Receiver
L
NO Switch Terminal
AC 230 V
COM COM
Thermostat rating max 3 (1) A - MAX
AC 230 V
3 (1) A
Thermostat
NO
COM Common Switch Terminal
RT310
Receiver rating max - 16 (5) A NO
NO
COM
NC
MAX OR
NO COM L N 16 (5) A
Voltage free Voltage free L, N Supply (230 V AC) N L
N L
Outputs M
NO / COM /NC terminals NO / COM terminals
NO
COM
NC
Temperature range 5 - 35°C 5 - 35°C L, N OR Napięcie
M zasila
AC 230 V N
L Kocioł
/ sterownik kot
ostat
0
Change the Setpoint temperature Pairing the RT310TX with the Receiver Installer Mode
Note: If you are using the RT310RF pack, the pairing between the thermostat and the receiver
is already done. 3 sec
If you bought the RT310TX and RXRT510 seperately then pair as follows. Please make sure that
receiver switchers are set on AUTO and ON position. Connect your receiver to power supply - LED
indicator will flash red.
Begin the pairing process
3 sec 3 sec
Actual room temperature. Press or to set the temperature.
Press three buttons at the same time
for 3 seconds.
2 seconds timeout. Actual room temperature. d03 Frost Protection setpoint temperature 5.0°C - 17.0°C 5.0°C
End the pairing process
Press the RESET button once. You can use a paper clip.
Your thermostat will be reset and will start up automatically.
3
TEST / PAIRING TEST / PAIRING
RESET
AUTO MANUAL
TEST / PAIRING