You are on page 1of 6

Supercritical CO2 Extractor

DESCRIPTION
The extraktLAB E-110 is the fastest, most advanced and most powerful CO2 extraction machine
on the market today. The machine is designed to provide high yield in a short period of time
while satisfying the traceability requirements for GMP compliancy.

extraktLAB’s supercritical CO2 extraction equipment can run a variety of extraction methods.

FEATURES
Sub or Supercritical CO2
Extractions

Full Spectrum Extracts

Fully Automated Methods

UL, ASME, PED, EPR Certified


Scalable
GMP Compliant Software

EXTENDED
PROCESSING POWER PROCESS CONTROL GMP COMPLIANCE
• Up to 79 lbs/day • Programmable methods • Automated process
• 1.5 kg/cycle • Automated extraction control
• 60 min/cycle @ 10% cycles • Batch, operator,
potency • Independent vessel parameter tracking
• 90+% hemp efficiency control • FDA approved materials
• 95+% marijuana efficiency • 0 - 5000 psi • Instrument calibrations
• 24 sq ft footprint • 25 - 100º C • Clean in place
• 57 Full Load Amps (FLA) • Cyclonic separation • International certifications
• Data capture/reporting • Calibration/maintenance
tracking
SPECIFICATIONS
ATTRIBUTE VALUE ATTRIBUTE VALUE
Biomass Input / Cycle 1-1.5kg Full Load Amps 57
Cycle Time @ 10% pp 60 min Voltage 208-240 VAC
Biomass Processing / Day 36 kg / 79 lbs Phase 1

Efficiency – Oil Recovery Hemp 90+% / Marijuana 95+% Frequency 50-60 Hz


Extraction Vessels 2 × 5L Flow Control Manual or Automatic
Collection Vessels 3 × 2.5L CO2 Supply 750-850 psi inlet
FDA approved, ASME 304 and 316
CO2 Recycle Vessel 20L Wetted Materials
Structural Grade Steel
Footprint 24 sq ft Separation Principle Cyclonic
Export data, diagnostics and event
logging, data traceability, unlimited
Shipping Weight 3,000 lbs Datasystem working level access, user
traceability method, CO2 lot, input lot
trace
21 CFR Part 117,211, 177 and Health
Canada equivalents, P.E. stamped
Dimensions (w/o light mast) H 72” × L 99” × W 34” Regulatory Compliance according to ASME DIV II VII-2 PED
compliant, CE marked, notified body
Lloyd’s Register, CRN number
Supercritical CO2, alcohol, non-polar
Operating Pressure 0 to 5,000 psi Cleaning Methods
solvents
Operating Temperature 25 to 100°C Calibration / Maintenance Software tracking built-in
Sound Pressure 40 db Training records Software tracking built-in
User Interface Touch Screen HMI Panel

LINE DRAWINGS

FRONT VIEW SIDE VIEW

651-464-2822 | EXTRAKTLAB.COM 500 SIMMON DR. OSCEOLA, WI 54020


Supercritical CO2 Extractor

DESCRIPTION
The extraktLAB E-140 is the fastest, most advanced and most powerful CO2 extraction machine
on the market today. The machine is designed to provide high yield in a short period of time
while satisfying the traceability requirements for GMP compliancy.

extraktLAB’s supercritical CO2 extraction equipment can run a variety of extraction methods.

FEATURES
Sub or Supercritical CO2
Extractions

Full Spectrum Extracts

Fully Automated Methods

UL, ASME, PED, EPR Certified


Scalable
GMP Compliant Software

EXTENDED
PROCESSING POWER PROCESS CONTROL GMP COMPLIANCE
• Up to 422 lbs/day • Programmable methods • Automated process
• 8 kg/cycle biomass • Automated extraction control
• 60 min/cycle @ 10% plant cycles • Batch, operator,
potency • Independent vessel parameter tracking
• 90+% hemp efficiency control • FDA approved materials
• 95+% marijuana efficiency • 0 - 5000 psi • Instrument calibrations
• 24 sq ft footprint • 25 - 100º C • Clean in place
• 67 Full Load Amps (FLA) • Cyclonic separation • International certifications
• Data capture/reporting • Calibration/maintenance
tracking
SPECIFICATIONS
ATTRIBUTE VALUE ATTRIBUTE VALUE

Biomass Input / Cycle 5-8kg Full Load Amps 67


Cycle Time @ 10% pp 60 min Voltage 208-240 VAC
Biomass Processing / Day 192 kg / 422 lbs Phase 3
Efficiency – Oil Recovery Hemp 90+% / Marijuana 95+% Frequency 50-60 Hz
Extraction Vessels 2 × 20L Flow Control Manual or Automatic
Collection Vessels 3 × 2.5L CO2 Supply 750-850 psi inlet
FDA approved, ASME 304 and 316
CO2 Recycle Vessel 20L Wetted Materials
Structural Grade Steel
Footprint 24 sq ft Separation Principle Cyclonic
Export data, diagnostics and event logging,
data traceability, unlimited working level
Shipping Weight 4,300 lbs Datasystem
access, user traceability method, CO2 lot,
input lot trace
21 CFR Part 117,211, 177 and Health
Canada equivalents, P.E. stamped
Dimensions (w/o light mast) H 72” × L 99” × W 34” Regulatory Compliance according to ASME DIV II VII-2 PED
compliant, CE marked, notified body
Lloyd’s Register, CRN number
Supercritical CO2, alcohol, non-polar
Operating Pressure 0 to 5000 psi Cleaning Methods
solvents
Operating Temperature 25 to 100°C Calibration / Maintenance Software tracking built-in
Sound Pressure 50 db Training records Software tracking built-in
User Interface Touch Screen HMI Panel

LINE DRAWINGS

FRONT VIEW SIDE VIEW

651-464-2822 | EXTRAKTLAB.COM 500 SIMMON DR. OSCEOLA, WI 54020


Supercritical CO2 Extractor

DESCRIPTION
The extraktLAB E-180 is the fastest, most advanced and most powerful CO2 extraction
machine on the market today. The machine is designed to provide high yield in a short
period of time while satisfying the traceability requirements for GMP compliancy.

extraktLAB’s supercritical CO2 extraction equipment can run a variety of extraction


methods.

FEATURES
Sub or Supercritical
CO2 Extractions

Full Spectrum Extracts

Fully Automated Methods

UL, ASME, PED, EPR


Certified
Scalable
GMP Compliant
Software

EXTENDED
PROCESSING POWER PROCESS CONTROL GMP COMPLIANCE
• Up to 844 lbs/day • Programmable methods • Automated process
• 16 kg/cycle biomass • Automated extraction control
• 60 min/cycle @ 10% plant cycles • Batch, operator,
potency • Independent vessel parameter tracking
• 90+% hemp efficiency control • FDA approved materials
• 95+% marijuana efficiency • 0 - 5000 psi • Instrument calibrations
• 48 sq ft footprint • 25 - 100º C • Clean in place
• 85 Full Load Amps (FLA) • Cyclonic separation • International certifications
• Data capture/reporting • Calibration/maintenance
tracking
SPECIFICATIONS
ATTRIBUTE VALUE ATTRIBUTE VALUE
Biomass Input / Cycle 10-16kg Full Load Amps 85
Cycle Time @ 10% pp 60 min Voltage 208-240 VAC
Biomass Processing / Day 384kg / 844 lbs Phase 3
Efficiency – Oil Recovery Hemp 90+% / Marijuana 95+% Frequency 50-60 Hz
Extraction Vessels 4 X 20L Flow Control Manual or Automatic
Collection Vessels 2 X 20L CO2 Supply 750-850 psi inlet
FDA approved, ASME 304 and 316
CO2 Recycle Vessel 20L Wetted Materials
Structural Grade Steel
Footprint 48 sq ft Separation Principle Cyclonic

Export data, diagnostics and event


logging, data traceability, unlimited
Shipping Weight 6,200 lbs Datasystem
working level access, user traceability
method, CO2 lot, input lot trace

21 CFR Part 117,211, 177 and Health


Canada equivalents, P.E. stamped
Dimensions (w/o light mast) H 72” × L 129” × W 53” Regulatory Compliance according to ASME DIV II VII-2 PED
compliant, CE marked, notified body
Lloyd’s Register, CRN number
Supercritical CO2, alcohol, non-polar
Operating Pressure 0 to 5000 psi Cleaning Methods
solvents
Operating Temperature 25 to 100°C Calibration / Maintenance Software tracking built-in
Sound Pressure 50 db Training records Software tracking built-in
User Interface Touch Screen HMI Panel

LINE DRAWINGS

FRONT VIEW SIDE VIEW

651-464-2822 | EXTRAKTLAB.COM 500 SIMMON DR. OSCEOLA, WI 54020