HVAC Unit Specifications and Capacities

This document provides specifications for various ducted blower indoor and outdoor unit models, including their nominal cooling capacities, power requirements, dimensions, and weights. The indoor units have nominal cooling capacities ranging from 70,000 to 300,000 BTU/h, while the outdoor units range from 72,000 to 300,000 BTU/h. Indoor unit dimensions vary between models, with heights between 572-1231 mm, widths of 1402-1766 mm, and depths of 605-1069 mm.

Uploaded by

Azrul Azim
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
155 views1 page

HVAC Unit Specifications and Capacities

This document provides specifications for various ducted blower indoor and outdoor unit models, including their nominal cooling capacities, power requirements, dimensions, and weights. The indoor units have nominal cooling capacities ranging from 70,000 to 300,000 BTU/h, while the outdoor units range from 72,000 to 300,000 BTU/h. Indoor unit dimensions vary between models, with heights between 572-1231 mm, widths of 1402-1766 mm, and depths of 605-1069 mm.

Uploaded by

Azrul Azim
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

Ducted Blower System (ADB-B/AMC) Ducted Blower System (ADB-B/AMC)

INDOOR UNIT ADB 80B ADB 100B ADB 125B INDOOR UNIT ADB 150B ADB 150B2 ADB 200B2 ADB 250B2 ADB 300B2 ADB 300B3
MODEL MODEL
OUTDOOR UNIT AMC 72C AMC 80C AMC 100B AMC 125B OUTDOOR UNIT AMC 150C AMC 80Cx2 AMC 100Bx2 AMC 125Bx2 AMC 150Cx2 AMC 100Bx3
BTU/h 70,000 80,000 100,000 125,000 BTU/h 150,000 200,000 250,000 300,000 300,000
NOMINAL CAPACITY NOMINAL CAPACITY
W 20,515 23,440 29,300 36,625 W 43,950 43,960 58,600 73,250 87,900 87,900
NOMINAL TOTAL INPUT POWER W 7,109 8,760 10,334 12,344 NOMINAL TOTAL INPUT POWER W 16,200 17,343 20,118 25,658 34,190 32,392
NOMINAL RUNNING CURRENT A 13.60 15.20 19.40 21.40 NOMINAL RUNNING CURRENT A 31.80 34.53 39.30 44.50 66.40 65.80
BTU/h/W 11.25 9.13 9.67 10.12 BTU/h/W 9.26 8.65 9.94 9.74 8.77 9.26
EER EER
W/W 2.89 2.68 2.84 2.97 W/W 2.71 2.53 2.91 2.85 2.57 2.71
POWER SOURCE V/Ph/Hz ID: 220 ~ 240/1/50 380 ~ 415 / 3 / 50 POWER SOURCE V/Ph/Hz 380 ~ 415 / 3 / 50
OD: 380 ~ 415/3/50
OPERATION WIRED CONTROL
OPERATION WIRED CONTROL (FIELD SUPPLY) CONTROL HORIZONTAL & VERTICAL &
CONTROL AIR DISCHARGE
AIR DISCHARGE HORIZONTAL HORIZONTAL & CONVERTIBLE CONVERTIBLE
CONVERTIBLE AIR FLOW HIGH l/s / CFM 2,171 / 4,600 3,021 / 6,400 3,776 / 8,000 4,248 / 9,000
AIR FLOW HIGH l/s / CFM 1,180 / 2,500 1,510 / 3,200 1,982 / 4,200
EXTERNAL STATIC PRESSURE
EXTERNAL STATIC PRESSURE Pa / [Link] 230 / 0.92 265 / 1.06 280 / 1.12 300 / 1.20
Pa / [Link] 100 / 0.4 230 / 0.92 WITHOUT FILTER
WITHOUT FILTER
SOUND PRESSURE LEVEL dBA 60 61 63 66
SOUND PRESSURE LEVEL dBA 50 53 58 INDOOR
INDOOR UNIT HEIGHT mm/in 885 / 34.8 1,231 / 48.5
HEIGHT mm/in 572 / 22.6 885 / 34.8 UNIT
UNIT DIMENSION WIDTH mm/in 1,540 / 60.7 1,794 / 70.7 1,766 / 69.5
UNIT DIMENSION WIDTH mm/in 1,402 / 55.2 1,540 / 60.7
DEPTH mm/in 850 / 33.5 1,069 / 42.0
DEPTH mm/in 605 / 23.8 850 / 33.5
HEIGHT mm/in 1154 / 45.4 1,506 / 59.3
HEIGHT mm/in 700 / 27.6 1,154 / 45.4
PACKING DIMENSION WIDTH mm/in 1,787 / 70.4 2,052 / 80.8 2,034 / 80.0
PACKING DIMENSION WIDTH mm/in 1562 / 61.5 1,787 / 70.4
DEPTH mm/in 1,188 / 46.8 1,412 / 55.6
DEPTH mm/in 845 / 33.3 1188 / 46.8
UNIT WEIGHT kg/lb 180 / 397 220 / 486 343 / 757
UNIT WEIGHT kg/lb 89 / 196 93 / 205 173 / 381
AIR FLOW l/s / CFM 5,475 / 11,600 2,832 / 6,000 2,926 / 6,200 5,475 / 11,600 2,926 / 6,200
AIR FLOW l/s / CFM 2,832 / 6,000 2,926 / 6,200
SOUND PRESSURE LEVEL dBA 74 65 74 65
SOUND PRESSURE LEVEL dBA 70 74 65
HEIGHT mm/in 1,041 / 41.0 946 / 37.2 946 / 37.2 1,041 / 41.0 946 / 37.2
HEIGHT mm/in 946 / 37.2 946 / 37.2 946 / 37.2
UNIT DIMENSION WIDTH mm/in 939 / 37.0 1,300 / 51.18 939 / 37.0
UNIT DIMENSION WIDTH mm/in 1,300 / 51.18 939 / 37.0
DEPTH mm/in 1,116 / 43.9 500 / 19.68 1,116 / 43.9
DEPTH mm/in 500 / 19.68 1,116 / 43.9
HEIGHT mm/in 1,227 / 48.3 1,132 / 44.56 1,132 / 44.6 1,227 / 48.3 1,132 / 44.6
HEIGHT mm/in 1,132 / 44.56 1,132 / 44.6
PACKING DIMENSION WIDTH mm/in 1,112 / 43.8 1,414 / 55.66 1,112 / 43.8
PACKING DIMENSION WIDTH mm/in 1,414 / 55.66 1,112 / 43.8 OUTDOOR
OUTDOOR UNIT UNIT DEPTH mm/in 1,312 / 51.7 664 / 26.14 1,312 / 51.7
DEPTH mm/in 664 / 26.14 1,312 / 51.7
UNIT WEIGHT kg/lb 227 / 500 145 / 320 164 / 361 169 / 372 227 / 500 164 / 361
UNIT WEIGHT kg/lb 145 / 320 164 / 361 169 / 373
TYPE BRAZED
TYPE BRAZED PIPE
PIPE LIQUID mm/in 15.88 / 5/8 12.7 / 1/2 15.88 / 5/8 15.9 /
LIQUID mm/in 12.7 / 1/2 15.88 / 5/8 CONNECTION SIZE
CONNECTION SIZE GAS mm/in 34.92 / 1 25.4 / 1.0 28.58 / 1 34.92 / 1
GAS mm/in 25.4 / 1.0 28.58 / 1
TYPE R22
TYPE R22
REFRIGERANT REFRIGERANT 9.90 / 6.8 / 7.6 x 2 / 7.95 x 2 / 9.9 x 2 / 7.6 x 3 /
CHARGE kg/lb 6.4 / 14.08 6.8 / 14.96 7.6 / 16.72 7.95 / 17.49 CHARGE kg/lb
21.78 14.96 16.8 x 2 17.49 x 2 21.78 x 2 16.8 x 3
Note:
1. All specifications are subjected to change by the manufacturer without prior notice.
2. All units are being tested and comply to ISO 13253. Note:
3. Nominal cooling capacity are based on the conditions below: 1. All specifications are subjected to change by the manufacturer without prior notice.
2. All units are being tested and comply to ISO 13253.
Cooling
3. Nominal cooling capacity are based on the conditions below:
Indoor 27˚C DB / 19˚C WB
Outdoor 35˚C DB / 24˚C WB Cooling
Indoor 27˚C DB / 19˚C WB
4. Indoor sound pressure level are according to JIS B 8615 standard.
Outdoor 35˚C DB / 24˚C WB
Horizontal Discharge: Position of the measurement point 1.5m below the unit.
(With 1m duct connect to the inlet and 2m duct connect to the outlet) 4. Indoor sound pressure level are according to JIS B 8615 standard.
Vertical Discharge : Position of the measurement point is 1m away from every side of the unit and 1m above floor level. Horizontal Discharge: Position of the measurement point 1.5m below the unit.
(With Tested with 2m length duct at discharge only) (With 1m duct connect to the inlet and 2m duct connect to the outlet)
Vertical Discharge : Position of the measurement point is 1m away from every side of the unit and 1m above floor level.
(With Tested with 2m length duct at discharge only)