Submittal AM160JXVANH/TL DVM S Latin America

Job Name Location


Purchaser Engineer
Submitted to Reference Approval Construction

Specifications
Model AM160JXVANH/TL
Features Type DVM S
Power Voltage [Φ, #, V, Hz] 3,4,380-415,50/60
MCA [A] 32.00 (MCA)
MFA [A] 40.00
Performance HP 16.00
Cooling [kW] 45.00
Cooling [Btu/h] 153,500
Heating [kW] 50.40
Heating [Btu/h] 172,000

Specifications
EER 3.95
COP 4.34
Power Input Cooling 1 [kW] 11.40
Heating 2 [kW] 11.60
Current Input (Nominal) Cooling 1 [A] 18.30
Heating 2 [A] 18.60 Compatibility
System Mode HEAT PUMP NASA DVM S indoor units , AHU kits (MXD-K***AN), and UCK (MCM-D211UN)
Compressor Type Construction
SSC Scroll x 2
The unit shall be galvanized steel with a baked on powder coated finish.
Output (kW x n) (4.39x2)
Heat Exchanger
Oil Type PVE The heat exchanger shall be mechanically bonded fin to copper tube.
Inicial Charge [cc] 1800 The aluminum fins of the heat exchanger shall have a protective coating.
Refrigerant Type R410A Salt spray test method: ASTM-B117-18 - the heat exchanger showed no unusual rust or
Factory Charge [kg] corrosion development to 2,280 hours.
7.70
Controls
Installation Max. Distance Length [m] 200
The outdoor unit shall have a removable EEPROM that stores unit serial number, startup
Height [m] 110.0 information, system settings, system tag/name, and other information.
Condenser Fan Fan Type Propeller Control wiring shall be 16 AWG X 2 shielded wire.
Output [CMM] 255 Refrigerant System
Output [CFM] 9005
The compressors shall be Samsung hermetically sealed, inverter driven, direct flash
injected, DC scroll type with soft-start capability.
Motor Output [W] 620.0 x 2
Flash injected compressors provide advanced low ambient heating performance.
E.S.P Max. [mmAq] 8.00 Subcooling devices in system maintain capacity at extreme system refrigerant pipe
E.S.P Max. [Pa] 78.45 lengths and minimize refrigerant noise.
Piping Connections Liquid Pipe (Φ, mm) 12.70 Other Features
Liquid Pipe (Φ, inch) 1/2" Asymmetrical scroll design with rotating compressor operation/priority (where
applicable).
Gas Pipe (Φ, mm) 28.58
Advanced oil recovery cycle logic (maximum duration in cool mode: 3 minutes, maximum
Gas Pipe (Φ, inch) 1 1/8" duration in heat mode: 6 minutes, defrost cycles lasting over 3 minutes are considered
Discharge (Φ,mm) - oil recovery cycles). Oil recovery operation shall not interrupt heating or cooling
Discharge (Φ,inch) - operation.
Sound Sound Pressure 63.0 Optional night quiet modes to reduce outdoor unit sound (4 levels) with automatic
Sound Power activation or manual activation (with MIM-B14).
83.0
Advanced intelligent defrost logic to significantly reduce defrost cycle frequency by
Dimension Net Weight(kg) 269.0 monitoring air resistance across the condenser coil during heating operation to
Shipping Weight (kg) 288.0 determine defrost operation initiation to prevent unnecessary defrost cycles.
Net Dimensions (WxHxD) (mm) 1,295 x 1,695 x 765 Optional snow blowing logic to prevent snow accumulation on idle outdoor units
Shipping Dimensions (WxHxD) (mm) 1,363 x 1,887 x 832 Maximum current control of outdoor unit(s) to limit current (50% - 100% of design
Operating Cooling [°C] current) adjustable at outdoor unit or central control devices: DMS 2.5 (MIM-D01AN),
-5.0 ~ 48.0
Temp. Range BACnet Gateway (MIM-B17BN), LON Gateway (MIM-B18BN).
Heating [°C] -25.0 ~ 24.0
Energy savings options to reduce system energy consumption when average indoor room
temperatures are greater than average indoor set temperatures in heating mode or when
* Nominal cooling capacities are based on: Indoor temperature: 80 ⁰F DB, 67⁰F WB. Outdoor temperature: 95⁰F DB, 75⁰F WB. average indoor room temperatures are lower than average indoor set temperatures in
* Nominal heating capacities are based on: Indoor temperature: 70 ⁰F DB, 60⁰F WB. Outdoor temperature: 47⁰F DB, 43⁰F WB. cooling mode.
Samsung maintains a policy of ongoing development, specifications are subject to change
without notice.

English 1

Samsung maintains a policy of ongoing development, specifications are subject to change without notice.
06/07/2023 2

Submittal AM160JXVANH/TL DVM S Latin America

Specifications

English 2

Samsung maintains a policy of ongoing development, specifications are subject to change without notice.
2. Specification
Standard - 50/60Hz
Model Name AM140AXVANH/EA AM160AXVANH/EA AM180AXVANH/EA
Outdoor unit module 1 - - -
Outdoor unit module 2 - - -
Outdoor unit module 3 - - -
Outdoor unit module 4 - - -
Power Supply Ø, #, V, Hz 3,4,380~415,50/60 3,4,380~415,50/60 3,4,380~415,50/60
Mode - HEAT PUMP HEAT PUMP HEAT PUMP
HP HP 14 16 18
Performance Cooling kW 40.0 45.0 50.4
Capacity
Heating kW 45.0 50.4 56.7
Maximum number of connectable indoor units EA 26 29 32

Total capacity of the connected Min. kW 20.0 22.5 25.2


Indoor Units Max. kW 52.0 58.5 65.5
Cooling kW 10.68 11.50 13.94
Power Input
Heating kW 11.08 11.58 13.50
Cooling A 16.80 18.00 21.70
Power Current Input
Heating A 16.90 18.20 21.20
MCA A 29.0 34.0 39.2
Current
MFA A 32 40 50
EER Cooling W/W 3.75 3.91 3.62
Efficiency
COP Heating W/W 4.06 4.35 4.20
Body - GI Steel Plate GI Steel Plate GI Steel Plate
Casing Material
Base - GI Steel Plate GI Steel Plate GI Steel Plate
Type - Fin & Tube Fin & Tube Fin & Tube
Heat Fin - Al Al Al
Material
Exchanger Tube - Cu Cu Cu
Fin Treatment - Anti-corrosion Anti-corrosion Anti-corrosion
Type - Inverter Scroll x 1 Inverter Scroll x 1 Inverter Scroll x 1
Output kW x n 6.67 x 1 8.93 x 1 8.93 x 1

Model Name - DS4GR7066FV* x 1 DS4GM7090FV* x 1 DS4GM7090FV* x 1


Compressor
Type - PVE PVE PVE
Oil
Initial charge cc x n 1,100 x 1 1,400 x 1 1,400 x 1

Type - Propeller Propeller Propeller


Discharge direction - Top Top Top
Quantity EA 1 2 2
Fan ㎥/min 201 293 313
Air Flow Rate
l/s 3,346 4,880 5,217

External Static mmAq 8 11 11


Max.
Pressure Pa 80 110 110
Type - BLDC Motor BLDC Motor BLDC Motor
Fan Motor
Output Wxn 630 x 1 620 x 2 620 x 2
2. Specification
Standard - 50/60Hz
Model Name AM140AXVANH/EA AM160AXVANH/EA AM180AXVANH/EA
Outdoor unit module 1 - - -
Outdoor unit module 2 - - -
Outdoor unit module 3 - - -
Outdoor unit module 4 - - -
Type Braze connection Braze connection Braze connection
Liquid Pipe
Φ, ㎜ (inch) 12.70 (1/2) 12.70 (1/2) 15.88 (5/8)
Type Braze connection Braze connection Braze connection
Gas Pipe
Φ, ㎜ (inch) 28.58 (1-1/8) 28.58 (1-1/8) 28.58 (1-1/8)
Heat Insulation - Both liquid and gas pipes Both liquid and gas pipes Both liquid and gas pipes
Piping length Max. [Equiv.] m 200[220] 200[220] 200[220]
(ODU-IDU)

Piping Piping length Max. m 90 90 90


(1st Branch-IDU)
Connections
Total piping
Max. m 1,000 1,000 1,000
length (System)
Level difference
(ODU in highest Max. m 110 110 110
position)

Level difference Max. m 110 110 110


(IDU in highest position)

Level difference Max. m 50 50 50


(IDU-IDU)

Transmission Min. ㎟ 0.75 0.75 0.75


Wiring Cable Remark - F1, F2 F1, F2 F1, F2
connections
Both indoor and Both indoor and Both indoor and
Power supply intake -
outdoor unit outdoor unit outdoor unit
Type - R410A R410A R410A
Refrigerant
Factory Charging kg 7.0 8.0 8.0
Sound Pressure (Cooling) dB(A) 63 59 59
Sound
Sound Power (Cooling) dB(A) 85 81 81
Net Weight kg 200 234 234
Shipping Weight kg 214 251 251
External
Dimension Net Dimensions (WxHxD) ㎜ 930 x 1,695 x 765 1,295 x 1,695 x 765 1,295 x 1,695 x 765

Shipping Dimensions (WxHxD) ㎜ 998 x 1,887 x 829 1,363 x 1,887 x 829 1,363 x 1,887 x 829

Operating Cooling ℃ -5 ~ 50 -5 ~ 50 -5 ~ 50
Temp. Range Heating ℃ -25 ~ 24 -25 ~ 24 -25 ~ 24

NOTE
• Specification may be subject to change without prior notice.
1) Performances are based on the following test conditions.
- Cooling : Indoor temperature 27°CDB, 19°CWB, Outdoor temperature 35°CDB, 24°CWB
- Heating : Indoor temperature 20°CDB, 15°CWB, Outdoor temperature 7°CDB, 6°CWB
- Equivalent refrigerant pipe length 5m, Level differences 0m
2) Performance of Multiple Module Outdoor unit is weighted average of Single Module outdoor units.
3) Allowed combination ratio of the total rated indoor unit capacity over the rated outdoor unit capacity is 50~130%.
4) Sound pressure level is obtained in an anechoic room.
- Sound pressure level is a relative value, depending on the distance and acoustic environment.
- Sound pressure level may differ depending on operation condition.
- dBA = A-weighted sound pressure level
- Reference acoustic pressure 0 dB = 20uPa
5) Sound power level is an absolute value that a sound source generates.
- dBA = A-weighted sound power level
- Reference power : 1pW
- Measured according to ISO 3741
6) Sound values of multi combination are theoretical values based on sound results of individual installed units.
7) These products contain R410A which is fluorinated greenhouse gas.
8) If outdoor unit is located in a higher position than indoor unit, level difference is 110m or under.
(If the level difference is higher than 50m, make a decision by PDM kit installation Guide software whether the PDM kit should be installed or not.)
- PDM kit: Pressure Drop Modulation kit
When the outdoor unit is below the indoor unit & the level differences are 40m or more, contact your local dealer for more information.
• In case you want to know more information regarding capacity and correction, please refer to capacity table TDB on pvi.samsung.com site.
06/07/2023 1

Submittal AM018NNNDCH/AA Wind-Free 4Way Cassette (600x600) Latin America

Job Name Location


Purchaser Engineer
Submitted to Reference Approval Construction

Specifications
Model AM018NNNDCH/AA
Features Type Wind-Free 4Way Cassette
(600x600)
Power Supply (Indoor Unit) [Φ, #, V, Hz] 1,2,208-230,60
Capacity Cooling [kW]

Specifications
5.28
Cooling [Btu/h] 18,000
Heating [kW] 5.86
Heating [Btu/h] 20,000 •Compatible with Samsung DVM S, DVM S Water, and DVM S Eco
Current Input (Nominal) Cooling 1 [A] 0.27 systems (AM**********/**).
Heating 2 [A] 0.27
•Electro-static, washable, pleated filters as standard (included with
System Mode HP/HR fascia panel)
Power Input (Nominal) Cooling 1 [W] 36.00
Heating 2 [W] 36.00 •Built in condensate pump with maximum 29" lift from the bottom of
Fan Type Turbo Fan the unit, check valve, and float switch that disables indoor unit during
Motor (Output) [W] overflow detection
65 x 1
Air Flow Rate (High / Mid / Low) [CFM] 459/388/336 •Knock-out for outside air capability
Air Flow Rate (High / Mid / Low) [CMM] 13.00/10.99/9.51
Air Flow Rate (High/Mid/Low) [L/S] 216.62/183.11/158.57 •Fascia panel shall have LED indicator lights and 4 motorized louvers
External Static Pressure (Min / Std / Max) [in H20] - with independent control (32° - 65° louver control range)
External Static Pressure (Min / Std / Max) [mmAq] -
•High-voltage terminal block temperature sensor to disable unit in the
External Static Pressure (Min / Std / Max) [Pa] - event overheating of power connection.
Piping Connections Liquid Pipe (Φ, mm) 6.35
Liquid Pipe (Φ, inch) 1/4" •Wind-Free™ function will close the supply air outlet louver while in
Gas Pipe (Φ, mm) 12.70 cooling mode to gently disperse cool air into the space without blowing
Gas Pipe (Φ, inch) directly onto occupants. The Wind-Free™ feature is optional and can be
1/2"
enabled using central or local control options (MWR-SH11N, MWR-
Drain Pipe (Φ,mm) VP25 (OD 32,ID 25) WE13N, MWR-WE13N, MWR-WG00*N, and AR-EH03U only).
Field Wiring Power Source Wire AWG 14
Transmission Cable 2 X 16 AWG SHIELDED •The Wind-Free™ 4-way cassette can be configured for 2-stage
Refrigerant Type R410A operation, cooling the space with the louver open (fixed or swing) until
Control Method the room temperature nears set temperature. Once room temperature
EEV INCLUDED
is near set temperature, Wind-Free™ operation will start automatically,
Sound Sound Pressure 39.0/36.0/33.0 closing the louver and using the face of the fascia panel to gently cool
Sound Power 56.0 the space with still air*.
External Dimension (Indoor Unit) Net Weight(kg) 12.00
Shipping Weight (kg) 14.00 •The Wind-Free™ panel (PC4NUFMUN) has an integral humidity sensor
Net Dimensions (WxHxD) (mm) that will open the louvers for standard cool mode when space
575 x 250 x 575
conditions could potentially cause condensation formation on the
Shipping Dimensions (WxHxD) (mm) 623 x 298 x 653 panel surface.
Panel Size Panel model PC4SUSMUN
Panel Net Weight (kg) 2.30 Construction
Shipping Weight (kg) 3.50 Insulated, HIPS chassis with a galvanized steel frame and fascia panel
Net Dimensions (WxHxD) (mm) certified to UL94 V0.
620 x 45 x 620
Shipping Dimensions (WxHxD) (mm) 661 x 106 x 671 Heat Exchanger
Additional Accessories Drain Pump - The heat exchanger shall be mechanically bonded fin to copper tube
Drain Pump Max. Lifting Height/Displacement - Indoor Fan
Air Filter Removable / Washable Indoor fan is a single turbo type
Three fan speed settings and auto setting

* Nominal cooling capacities are based on: Indoor temperature: 80 ⁰F DB, 67⁰F WB. Outdoor temperature: 95⁰F DB, 75⁰F WB.
Controls
* Nominal heating capacities are based on: Indoor temperature: 70 ⁰F DB, 60⁰F WB. Outdoor temperature: 47⁰F DB, 43⁰F WB.
The unit shall be operated via a wireless or wired remote control with

English 1

Samsung maintains a policy of ongoing development, specifications are subject to change without notice.
06/07/2023 2

Submittal AM018NNNDCH/AA Wind-Free 4Way Cassette (600x600) Latin America

Specifications

English 2
Samsung maintains a policy of ongoing development, specifications are subject to change without notice.
Page 1 of 2
SUBMITTAL AM012TNVDCH/AA
Samsung DVM S Series, Wind-Free™ Wall-Mounted Unit
Job Name Location
Purchaser Engineer
Submitted to Reference Approval Construction
Unit Designation Schedule #

Specifications
Nominal Cooling (Btu/h) 12,000
Performance
Capacity1 Heating (Btu/h) 13,500

Voltage (ø/V/Hz) 1 / 208-230 / 60


Nominal Running Current (A) 0.25
Power
MCA 0.31 • Compatible with Samsung DVM S, DVM S Water, and DVM S Eco
MOP 15 systems (AM**********AA).

Type Crossflow • Electro-static, washable, pleated filters as standard (included


with unit)
Fan Type BLDC (1)
Motor • 7-segment digital display on front of unit to display temperature and
Output (W) 27 unit status

Airflow CFM (UL) L/M/H 293 / 321 / 364 • High-voltage terminal block temperature sensor to disable unit in
the event overheating of power connection.
Type R410A
Refrigerant • Wind-Free™ function will close the supply air outlet louver while in
Control Method Electronic Expansion Valve
cooling mode to gently disperse cool air into the space without
blowing directly onto occupants. The Wind-Free™ feature is
Liquid (flare) Inches 1/4 optional and can be enabled using central or local control options
Piping (MWR-SH11UN, MWR-WE13UN, MWR-WG00*N, and AR-EH0*U
Suction (flare) Inches 1/2
Connections only).
Drain Inches ID 11/16 Hose
Construction
WXHXD Inches 32 5/16 X 11 3/4 X 8 7/16 HIPS chassis certified to UL94 V0 with galvanized steel mounting
Unit Dimensions
Weight lbs. 20.9 bracket

Heat Exchanger
Sound Level L/M/H dB(A) 34 / 36 / 40
The heat exchanger shall be mechanically bonded fin to copper
tube
External Contact Control MIM-B14
Aspen Mini Orange ASP-MO-UNIV 110-250 Indoor Fan
Condensate
Accessories Indoor fan is a single, antibacterial, crossflow type
Pump Blue Diamond BD-BLUE230
Three fan speed settings and auto setting
External Temperature Sensor MRW-TA
Automatic (motorized) vertical swing (up/down) and horizontal swing
Safety Certifications ETL (UL 1995) (left/right) louvers
1 Nominalcooling capacities are based on: Indoor temperature: 80°F DB, 67°F WB. Outdoor temperature: 95°F DB, 75°F WB
Nominal heating capacities are based on: Indoor temperature: 70°F DB, 60°F WB. Outdoor temperature: 47°F DB, 43°F WB
Controls
*The Wind-Free™ unit delivers an air current that is under 0.15 m/s while in Wind-Free™ mode. Air velocity that is The unit shall be operated via a wireless or wired remote control
below 0.15 m/s is considered “still air” as defined by ASHRAE (American Society of Heating, Refrigerating, and with DDC type signal
Air-Conditioning Engineers).

Samsung HVAC maintains a policy of ongoing development, specifications are subject to change without notice.
The unit shall integrate with the Samsung NASA Controls Network
Solution

Controls shall integrate with a BMS system

Control wiring shall be 2 X 16 AWG shielded wire

© 2020 Samsung HVAC www.SamsungHVAC.com


SHA-DVMS-05052020 888-699-6067
Page 2 of 2
SUBMITTAL AM012TNVDCH/AA
Samsung DVM S Series, Wind-Free™ Wall-Mounted Unit

Unit: inches

32 5/16 8 7/16

2 9/16
2 1/16

11 3/4
1 7/8

2 7/16
32 5/16

15 11/16 16 5/8
11 3/4

1 1/8

1 1/8
2 9/1
6 /16
29

6 15/16 15 5/8 3 5/16


2 1/2 2 1/2

Minimum clearances from walls and ceiling

3 15/16" Minimum

5" Minimum 5" Minimum

www.SamsungHVAC.com
Page 1 of 2
SUBMITTAL AM018TNVDCH/AA
Samsung DVM S Series, Wind-Free™ Wall-Mounted Unit
Job Name Location
Purchaser Engineer
Submitted to Reference Approval Construction
Unit Designation Schedule #

Specifications
Nominal Cooling (Btu/h) 18,000
Performance
Capacity1 Heating (Btu/h) 20,000

Voltage (ø/V/Hz) 1 / 208-230 / 60


Nominal Running Current (A) 0.35
Power
MCA 0.44 • Compatible with Samsung DVM S, DVM S Water, and DVM S Eco
MOP 15 systems (AM**********AA).

Type Crossflow • Electro-static, washable, pleated filters as standard (included


with unit)
Fan Type BLDC (1)
Motor • 7-segment digital display on front of unit to display temperature and
Output (W) 27 unit status

Airflow CFM (UL) L/M/H 424 / 487 / 555 • High-voltage terminal block temperature sensor to disable unit in
the event overheating of power connection.
Type R410A
Refrigerant • Wind-Free™ function will close the supply air outlet louver while in
Control Method Electronic Expansion Valve
cooling mode to gently disperse cool air into the space without
blowing directly onto occupants. The Wind-Free™ feature is
Liquid (flare) Inches 1/4 optional and can be enabled using central or local control options
Piping (MWR-SH11UN, MWR-WE13UN, MWR-WG00*N, and AR-EH0*U
Suction (flare) Inches 1/2
Connections only).
Drain Inches ID 11/16 Hose
Construction
WXHXD Inches 41 1/2 X 11 3/4 X 8 7/16 HIPS chassis certified to UL94 V0 with galvanized steel mounting
Unit Dimensions
Weight lbs. 26.5 bracket

Heat Exchanger
Sound Level L/M/H dB(A) 34 / 37 / 40
The heat exchanger shall be mechanically bonded fin to copper
tube
External Contact Control MIM-B14
Aspen Mini Orange ASP-MO-UNIV 110-250 Indoor Fan
Condensate
Accessories Indoor fan is a single, antibacterial, crossflow type
Pump Blue Diamond BD-BLUE230
Three fan speed settings and auto setting
External Temperature Sensor MRW-TA
Automatic (motorized) vertical swing (up/down) and horizontal swing
Safety Certifications ETL (UL 1995) (left/right) louvers
1 Nominalcooling capacities are based on: Indoor temperature: 80°F DB, 67°F WB. Outdoor temperature: 95°F DB, 75°F WB
Nominal heating capacities are based on: Indoor temperature: 70°F DB, 60°F WB. Outdoor temperature: 47°F DB, 43°F WB
Controls
*The Wind-Free™ unit delivers an air current that is under 0.15 m/s while in Wind-Free™ mode. Air velocity that is The unit shall be operated via a wireless or wired remote control
below 0.15 m/s is considered “still air” as defined by ASHRAE (American Society of Heating, Refrigerating, and with DDC type signal
Air-Conditioning Engineers).

Samsung HVAC maintains a policy of ongoing development, specifications are subject to change without notice.
The unit shall integrate with the Samsung NASA Controls Network
Solution

Controls shall integrate with a BMS system

Control wiring shall be 2 X 16 AWG shielded wire

© 2020 Samsung HVAC www.SamsungHVAC.com


SHA-DVMS-05052020 888-699-6067
Page 2 of 2
SUBMITTAL AM018TNVDCH/AA
Samsung DVM S Series, Wind-Free™ Wall-Mounted Unit

Unit: inches

41 1/2 8 7/16

2 5/16

2 9/16

11 3/4
2 7/16

2 7/16
41 1/2

20 3/8 21 1/8

1 1/8
29
11 3/4

1 1/8

/16 16
2 9/

24 7/8
6 15/16 2 1/2 2 1/2 3 5/16

Minimum clearances from walls and ceiling

3 15/16" Minimum

5" Minimum 5" Minimum

www.SamsungHVAC.com
Page 1 of 2
SUBMITTAL AM028TNVDCH/AA
Samsung DVM S Series, Wind-Free™ Wall-Mounted Unit
Job Name Location
Purchaser Engineer
Submitted to Reference Approval Construction
Unit Designation Schedule #

Specifications
Nominal Cooling (Btu/h) 28,000
Performance
Capacity1 Heating (Btu/h) 29,000

Voltage (ø/V/Hz) 1 / 208-230 / 60


Nominal Running Current (A) 0.43
Power
MCA 0.54 • Compatible with Samsung DVM S, DVM S Water, and DVM S Eco
MOP 15 systems (AM**********AA).

Type Crossflow • Electro-static, washable, pleated filters as standard (included


with unit)
Fan Type BLDC (1)
Motor • 7-segment digital display on front of unit to display temperature and
Output (W) 27 unit status

Airflow CFM (UL) L/M/H 487 / 551 / 618 • High-voltage terminal block temperature sensor to disable unit in
the event overheating of power connection.
Type R410A
Refrigerant • Wind-Free™ function will close the supply air outlet louver while in
Control Method Electronic Expansion Valve
cooling mode to gently disperse cool air into the space without
blowing directly onto occupants. The Wind-Free™ feature is
Liquid (flare) Inches 3/8 optional and can be enabled using central or local control options
Piping (MWR-SH11UN, MWR-WE13UN, MWR-WG00*N, and AR-EH0*U
Suction (flare) Inches 5/8
Connections only).
Drain Inches ID 11/16 Hose
Construction
WXHXD Inches 41 1/2 X 11 3/4 X 8 7/16 HIPS chassis certified to UL94 V0 with galvanized steel mounting
Unit Dimensions
Weight lbs. 28.7 bracket

Heat Exchanger
Sound Level L/M/H dB(A) 43 / 45 / 46
The heat exchanger shall be mechanically bonded fin to copper
tube
External Contact Control MIM-B14
Aspen Mini Orange ASP-MO-UNIV 110-250 Indoor Fan
Condensate
Accessories Indoor fan is a single, antibacterial, crossflow type
Pump Blue Diamond BD-BLUE230
Three fan speed settings and auto setting
External Temperature Sensor MRW-TA
Automatic (motorized) vertical swing (up/down) and horizontal swing
Safety Certifications ETL (UL 1995) (left/right) louvers
1 Nominalcooling capacities are based on: Indoor temperature: 80°F DB, 67°F WB. Outdoor temperature: 95°F DB, 75°F WB
Nominal heating capacities are based on: Indoor temperature: 70°F DB, 60°F WB. Outdoor temperature: 47°F DB, 43°F WB
Controls
*The Wind-Free™ unit delivers an air current that is under 0.15 m/s while in Wind-Free™ mode. Air velocity that is The unit shall be operated via a wireless or wired remote control
below 0.15 m/s is considered “still air” as defined by ASHRAE (American Society of Heating, Refrigerating, and with DDC type signal
Air-Conditioning Engineers).

Samsung HVAC maintains a policy of ongoing development, specifications are subject to change without notice.
The unit shall integrate with the Samsung NASA Controls Network
Solution

Controls shall integrate with a BMS system

Control wiring shall be 2 X 16 AWG shielded wire

© 2020 Samsung HVAC www.SamsungHVAC.com


SHA-DVMS-05052020 888-699-6067
Page 2 of 2
SUBMITTAL AM028TNVDCH/AA
Samsung DVM S Series, Wind-Free™ Wall-Mounted Unit

Unit: inches

41 1/2 8 7/16

2 5/16

2 9/16

11 3/4
2 7/16

2 7/16
41 1/2

20 3/8 21 1/8

1 1/8
29
11 3/4

1 1/8

/16 16
2 9/

24 7/8
6 15/16 2 1/2 2 1/2 3 5/16

Minimum clearances from walls and ceiling

3 15/16" Minimum

5" Minimum 5" Minimum

www.SamsungHVAC.com
06/07/2023 1

Submittal AM036KNMDCH/AZ MSP DUCT Latin America

Job Name Location


Purchaser Engineer
Submitted to Reference Approval Construction

Specifications
Model AM036KNMDCH/AZ
Features Type
MSP DUCT

Power Supply (Indoor Unit) [Φ, #, V, Hz] 1,2,208-230,60


Capacity Cooling [kW]

Specifications
10.55
Cooling [Btu/h] 36,000
Heating [kW] 11.72
Heating [Btu/h] 40,000 • Compatible with Samsung DVM S, DVM S Water, and DVM Eco
Current Input (Nominal) Cooling 1 [A] 1.60 systems (AM*********/**).
Heating 2 [A] 1.60
• The indoor unit shall have an internal condensate pump as standard
System Mode HP/HR with float switch (maximum 29" lift from bottom of unit).
Power Input (Nominal) Cooling 1 [W] 290.00
Heating 2 [W] 290.00 • High-voltage terminal block temperature sensor to disable unit in the
Fan Type Sirocco Fan event overheating of power connection.
Motor (Output) [W] 180 x 1
• Discharge air temperature sensor with target discharge temperature
Air Flow Rate (High / Mid / Low) [CFM] 954/883/812 control capability
Air Flow Rate (High / Mid / Low) [CMM] 27.01/25.00/22.99
Air Flow Rate (High/Mid/Low) [L/S] 450.17/416.67/383.17 Construction
External Static Pressure (Min / Std / Max) [in H20] 0.24/0.31/0.39 The unit shall be constructed of insulated, galvanized steel
External Static Pressure (Min / Std / Max) [mmAq] 6.10/7.87/9.91
Heat Exchanger
External Static Pressure (Min / Std / Max) [Pa] 59.82/77.18/97.18 The heat exchanger shall be mechanically bonded fin to copper tube
Piping Connections Liquid Pipe (Φ, mm) 9.52
Liquid Pipe (Φ, inch) 3/8" Indoor Fan
Gas Pipe (Φ, mm) 15.88 Indoor fan is a centrifugal type with a single fan motor
Gas Pipe (Φ, inch) 5/8"
Three fan speed settings and auto setting
Drain Pipe (Φ,mm) VP25 (OD 32,ID 25)
Field Wiring Power Source Wire AWG 14 Fan output can be configured during commissioning for variousexternal
Transmission Cable 2 X 16 AWG SHIELDED static pressure ranges
Refrigerant Type R410A
Control Method Controls
EEV INCLUDED
The unit shall be operated via a wireless or wired remote control with
Sound Sound Pressure 41.0/38.0/35.0 DDC type signal
Sound Power 61.0
External Dimension (Indoor Unit) Net Weight(kg) 36.00 The unit shall integrate with the Samsung NASA Controls Network
Shipping Weight (kg) 41.00 Solution
Net Dimensions (WxHxD) (mm) 1150 x 320 x 480
Controls shall integrate with a BMS system
Shipping Dimensions (WxHxD) (mm) 1420 x 400 x 595
Panel Size Panel model - Control wiring shall be 2 X 16 AWG shielded wire
Panel Net Weight (kg) -
Shipping Weight (kg) - Air Filtration
Net Dimensions (WxHxD) (mm) The unit shall ship with basic filtration as standard
-
Shipping Dimensions (WxHxD) (mm) - Pressure drop across the filter must be factored into the total ESP.
Additional Accessories Drain Pump MDP-M075SGU1D
Drain Pump Max. Lifting Height/Displacement -
Air Filter Removable / Washable

* Nominal cooling capacities are based on: Indoor temperature: 80 ⁰F DB, 67⁰F WB. Outdoor temperature: 95⁰F DB, 75⁰F WB.
* Nominal heating capacities are based on: Indoor temperature: 70 ⁰F DB, 60⁰F WB. Outdoor temperature: 47⁰F DB, 43⁰F WB.

English 1

Samsung maintains a policy of ongoing development, specifications are subject to change without notice.
06/07/2023 2

Submittal AM036KNMDCH/AZ MSP DUCT Latin America

Specifications

English 2
Samsung maintains a policy of ongoing development, specifications are subject to change without notice.
06/07/2023 1

Submittal AR-EH03E Wireless remote controller Latin America

Job Name Location


Purchaser Engineer
Submitted to Reference Approval Construction

Specifications
Model AR-EH03E
Features Type Wireless remote controller

Specifications

• Multi-channel wireless control of Samsung indoor units

• Can control up to 4 indoor units individual (setup required)

• Wide display

• Soft-touch buttons

Specifications
Compatibility
• Control options: ON/OFF, set temperature, mode, fan speed, filter reminder reset, independent louver control
(AM0***N4DCH, AM0***NNDCH/**, AC0***N4DCH/**, and AJ0***NNDCH/** only), airflow direction, single event timer
• DVM S indoor units (AM0***N****/**)
setting, Wind-FreeTM Cooling and Long Reach functions (applies to supported models when using the Wind-FreeTM fascia
panel).
• Free Joint Multi (FJM) mini 4-way cassette (AJ0***NNDCH/**,
AJ0**NBNDCH/**)
• Indoor unit address and option setting programming mode

• Single zone CAC 4-way cassette systems (AC0***N4DCH/**)


• Includes holder to mount on wall

• Single zone CAC duct systems (AC0***NHDCH/**, AC0**NMDCH/**,


• Dimensions (W X L X H): 1 13/16" X 5 3/8" X 13/16"
AC0***NLDCH/**)

**Requires the installation of MRK-A10N wireless receiver kit**

English 1

Samsung maintains a policy of ongoing development, specifications are subject to change without notice.
06/07/2023 2

Submittal AR-EH03E Wireless remote controller Latin America

Specifications

English 2
Samsung maintains a policy of ongoing development, specifications are subject to change without notice.
06/07/2023 1

Submittal MWR-SH11N Wired remote controller Latin America

Job Name Location


Purchaser Engineer
Submitted to Reference Approval Construction

Specifications
Model MWR-SH11N
Features Type Wired remote controller

Features
• Internal temperature sensor

• Backlight

• Built-in infrared receiver to allow control of indoor unit wirelessly with AR-EH03U or AR-KH03U wireless controllers

• Indoor unit operation ON/OFF, operation mode, set temperature, louver position (cassette, ceiling, wall units), and fan
speed settings

Specifications
Specifications
• Error display
• Compatible with Samsung DVM S Systems (AM****X****/**,
AM0***XMDCH/**) and CAC systems (AC0***X**CH/**) only.
• Filter replacement alarm display and reset
• Can connect and control up to 16 indoor units on a single system or
across multiple systems (group control)
• Single indoor unit control or multiple unit control (maximum 16 units)
• 2 Conductor connection
• DC 12V power supplied by indoor unit
• All button lock (option)
• PLC (power line communication) is done on F3/F4 terminals.
• MWR-SH11N has screw terminals for all wiring connections, wire is
• Partial controller button lock (ON/OFF, temperature setting, fan speed, timer function, louver swing, sleep function, quiet
not included
function, outing function, and operation mode buttons)
• 16 AWG X 2 shielded cable is necessary for proper operation
• Maximum wire length: 328' from MWR-SH11N to farthest indoor unit.
• Upper and lower temperature setting restriction

• Heat, cool, dry, fan, and auto mode skip options (skips specified mode on wired controller)

• Restrict wireless controller signal (optional)

• Single event timer function (ON/OFF control, 30 minutes - 24 hours timer setting options)

• System/indoor unit function and operation indication (defrost, error, restricted controller, central control, and SPi status)

• Service mode for connected indoor unit operation monitoring, addressing, and setup

• Can be used to specify "Mode Master" while connected to a single indoor unit when used with heat pump systems to control
system mode (heating or cooling)

• Outing function to keep a minimum heating (61~72°F) and cooling (77~86°F) temperature while you are away. When Outing
mode is activated, the unit will operate at the specified Outing temperature.
If indoor temperature is 9°F difference from desired Outing temperature, the indoor unit will turn on. If indoor temperature is
the same as desired Outing temperature, the indoor unit will turn off automatically. This is repeated depending on indoor
temperature for 12 hours. After 12 hours, Outing mode is released /canceled.

• Wind-FreeTM Control (applies to supported models when using


the Wind-FreeTM fascia panel)

• Long Reach Function (applies to supported models when using


the Wind-FreeTM fascia panel)

English 1

Samsung maintains a policy of ongoing development, specifications are subject to change without notice.
06/07/2023 2

Submittal MWR-SH11N Wired remote controller Latin America

Specifications

English 2
Samsung maintains a policy of ongoing development, specifications are subject to change without notice.
06/07/2023 1

Submittal MXJ-YA2512M Y-joint Latin America

Job Name Location


Purchaser Engineer
Submitted to Reference Approval Construction

Specifications
Model MXJ-YA2512M
Features Type Y-joint

• Required component for Samsung DVM S and DVM Eco systems (AM****X****/**) with multiple evaporators and/or Mode
Change Units (MCU)
• Constructed of brazed copper or brass and copper
• Indoor unit Y-joint models include both liquid and suction fittings, insulation, and ties to secure insulation
• Heat recovery (HR) Y-joint models are required for branching the hot gas pipe throughout heat recovery systems (HR
systems only)
• Included insulation shall be polystyrene certified to UL94 V0, 5/8" wall thickness
• Inlet pipe shall be adjustable to facilitate different pipe sizes without having to braze additional fittings MW
• Each model shall include adjustable reducers as noted in the table below

Specifications

English 1

Samsung maintains a policy of ongoing development, specifications are subject to change without notice.
06/07/2023 2

Submittal MXJ-YA2512M Y-joint Latin America

Specifications

English 2

Samsung maintains a policy of ongoing development, specifications are subject to change without notice.