Purpose: The purpose of blog to explains about purpose control indicators of result
confirmation in MIC.
Also Read: SAP QM Certification Preparation Guide
Here we will discuss about control indicators Like

 Required charc
 Optional Charc
 After Acceptance
 After Rejection
Required Charc:
If inspection characteristic is must to record the results then we must choose “Required
Charc”. Valuation should be done, and value should be 5 in results recording otherwise
system will not allow you to take UD.
Optional Charc:
If inspection characteristic is optional to record the results then we must choose “Optional
Charc”. Valuation is not mandatory. system will allow you to take UD without forceful.
After Acceptance:
Business may have scenario that there will be some inspection characteristics which they
perform only in the case of previous inspection characteristics got Accepted.
After Rejection:
Business may have scenario that there will be some inspection characteristics which they
perform only in the case of previous inspection characteristics got rejected.
Now will do testing by using some MICs with these control indicators and will see
how these settings work.
 # MIC CONTROL INDICATOR SETTING 
1  LENGHTH  Required Charc
2  OPTIONAL  Optional Charc 
3  REQUIRED  Required Charc
4  ACCEPTED  After acceptance 
5  SURFACE  Required Charc 
6  REJECTED  After Rejection 
Created below MICs with highlighted control indicator settings

 MIC: LENGHTH (it contains required Charc)


 OPTIONAL MIC (it contains Optional Charc)
 REQUIRED MIC (it contains required Charc)
 ACCEPTED MIC (it contains After acceptance)
 SURFACE (it contains required Charc)
 REJECTED MIC (it contains After Rejected)
To test the functionality of these MICs we must maintain these MICs in Inspection plan then
create inspection lot and then results recording.
Create Inspection lot manually (QA01):
Create inspection lot through QA01 and save it
Result recording (QA32):
When you do results recording, initial inspection chars will be appearing as below
Here LENGTH is Required charc so status showing as 1 whereas optional MIC is having
status as 0 the reason is OPTIONAL MIC having optional control indicator settings (as
mentioned in the above screen shots) so it is not mandatory to enter results.
If you see ACCEPTED MIC, it is greyed out and its status is A. It will be active when the
previous inspection charc is accepted that means if the REQUIRED MIC (3rd MIC in this
list) is accepted the ACCEPTED MIC will become active
If you see REJECTED MIC, it is greyed out and its status is B. It will be active when the
previous inspection charc is accepted that means if the REQUIRED MIC (3rd MIC in this
list) is accepted the ACCEPTED MIC will become active
Let me record the results now and will see how ACCPETED MIC (After acceptance) will
function
If you see above screen, once 3rd Inspection char (REQUIRED MIC) become accepted,
ACCEPTED MIC grayed out gone & it become input field
Now will see how REJECTED MIC (After Rejection), will function.

If you see “SURFACE” inspection char got rejected and REJECTED MIC greyed out gone
and it became input field. Enter the results and save.
Usage decision (QA32):
Even though 2nd inspection char i.e OPTIONAL MIC is not filled with results and not
valuated, system will allow you to do usage decision without forceful