You are on page 1of 4

www.osram.

com OSRAM APAC

Benefits
LINEARlight – LM01C
Data Sheet  Energy saving low-power LED module for shelf,
under-cabinet and accent lighting.
 Flexible length, can be cut at each 56mm and
84mm
 Easy and fast installation with OSRAM
CONNECTsystem, seamless connection, no
shadow.
 Slim size and low profile, good for narrow space
installation.
 High colour consistency CRI>80 provides fine
and comfort light output.

Applications
 Shelf lighting for retails and supermarkets.
 Under-cabinet lighting for offices, commercials
and residential use etc.
 Accent lighting or back lighting for machines,
emergency or rescue sign.

Technical Operating Data


Wavelength
No. of Voltage Power Current Radiance Lum. Flux
Product Color Angle Color Temp
LEDs [V DC]* [W]* [mA]* [lm]*
[°]* [K]*
LM01C-LIN-280-827-500 White 36 24 4 165 120° 2700 K 260
LM01C-LIN-280-857-500 White 36 24 4 165 120° 5700 K 280
LM01C-LIN-280-865-500 White 36 24 4 165 120° 6500K 280

*) All Data are related to the entire module.


Due to the special conditions of the manufacturing processes of LED the typical data of technical parameters can only reflect statistical figures and do not
necessarily correspond to the actual parameters of each single product which could differ from the typical data.

Technical Features
 Size of printed circuit board (L x W x H):  Up to 50,000 h lifetime at Tc = 55 oC.
504 mm x 10 mm x 2.9 mm  Max. up to 8 modules in consecutive connection
 Size of smallest unit (L x W): from one power feed.
56 mm x 10 mm  Accessories:
 The maximum LED pitch is 14 mm -- LINEARlight Optics 26o special for LM01C in 6 pcs
LED length (84mm), can be cut into 4pcs LED length
 Entire Module consists of 36 LEDs (56mm) to fit for the smallest unit without any tool at
 Connection possible at the reel end or at the cut the V-cut groove.
points -- LM CONNECTsystem with 2-pin connection cable
for terminal connection and connector for inter-
module connection at each cut point or in between
two boards.

LM01C – Nov. 2013 V2.2 Page 1 of 4


www.osram.com OSRAM APAC

Minimum / Maximum Ratings


Storage
Operating Temperature Voltage Range Reverse Voltage
Product Temperature
at Tc-Point [°C]* [V dc]* [V dc]*
[°C]*
LM01C-LIN-280-827-500 -20 … 55 -30 … 85 23 … 25 25
LM01C-LIN-280-857-500 -20 … 55 -30 … 85 23 … 25 25
LM01C-LIN-280-865-500 -20 … 55 -30 … 85 23 … 25 25
*) Exceeding maximum ratings for operating and storage temperature will reduce expected life time or destroy the LED Modules.
Exceeding maximum ratings for operating voltage will cause hazardous overload and will likely destroy the LED Modules.
The temperature of the LED modules must be measured at the Tc-point according to EN60598-1 in a thermally constant status with a temperature sensor or a temperature
sensitive label.

Dimensions
LINEARlight LM01C

4 & 6 LEDs design,


can be cut at each
section for flexible
length requirement

Accessories
CONNECTsystem
LM-2PIN LM-2CONN LM-2CONN-50 OS-OP6x1

LM01C – Nov. 2013 V2.2 Page 2 of 4


www.osram.com OSRAM APAC

Safety Information
 The LED module itself and all its components must not be mechanically stressed.
 The mounting of the module has to be done on a metal heat sink.
 Assembly must not damage or destroy conducting paths on the circuit board.
 To avoid mechanical damage to the connecting cables, the module should be attached securely to the
intended substrate. Heavy vibration should be avoided.
 The mounting of the module is carried out by attaching it at the mounting holes. Mounting screws should be
treated with synthetic washers to prevent circuit board damage and possible short circuiting.

The LED module incorporates no protection against short circuits, overload or overheating.

In order to drive OSRAM LED-Modules safely, it is absolutely necessary to operate them with an electronically
stabilized power supply protecting against short circuits, overload and overheating.

For dimming applications attention should be paid to specific references in “OPTOTRONIC ® Technical Guide”.
To also ease the luminaire/installation approval, electronic control gear for LED or LED modules must carry the CE mark.
In Europe the declarations of conformity must include the following standards:
CE: EN 61347-2-13, EN 55015, EN 61547 and EN 61000-3-2.
Also check for the mark of an independent authorized certification institute.
Please see the relevant application guides for more detailed information.

When using power supplies other than OPTOTRONIC ® the following basic safety features are required, in addition to any
other application specific concerns and local safety codes.

OSRAM OPTOTRONIC® electronic control gear complies to all relevant standards and guarantees safe operation.

 Installation of LED modules (with power supplies) needs to be made with regard to all applicable electrical and
safety standards. Only qualified personnel should be allowed to perform installations.
 Observe correct polarity!
Depending on the product incorrect polarity will lead to emission of red or no light. The module can be
destroyed! Correct polarity immediatelly! (see "reverse voltage", page 2).
 Parallel connection is highly recommended as safe electrical operation mode. Serial connection is not
recommended. Unbalanced voltage drop can cause hazardous overload and damage the LED module.
 Pay attention to ESD steps when mounting the module.
 When do you use the connector LM-CONN pay attention that the modules are assembled in a level. No
contact safety otherwise is given
 The LINEARlight can typically survive transient current levels of up to 1.5 Amperes. As a general design
precaution, if the maximum output current of the power supply is more than 1.5 Amperes, fast- blow fuses
should be incorporated into the wiring plan
 Electrical contact is achieved with the contact cables. A maximum number of 8 modules can be installed
consecutively from one power feed. Operation with more than 8 consecutive modules will reduce photometric
performance and exceed the current carrying capacity of the module.
 The module, as manufactured, has no conformal coating and therefore offers no inherent protection against
corrosion.
 Damage by corrosion will not be honored as a materials defect claim. It is the user's responsibility to provide
suitable protection against corrosive agents such as moisture and condensation and other harmful elements.
 If the IP rating of the fixture should be higher than IP20, the design of the housing should be according to the
IP standards in the application.

LM01C – Nov. 2013 V2.2 Page 3 of 4


www.osram.com OSRAM APAC

Assembly Information
 The mounting of the module has to be done on a metal heat sink
 In order to optimize the thermal management the metal surface needs to be clean (dirt and oil free) and
planar for the best contact with the LED module.
 To connect one module, the feeder LM-2PIN must be plugged in the "INPUT" side of the module.
for two or more modules, the "OUTPUT"-side of the first module must be connected with the "INPUT"-side
of following module via LM-2CONN. Please connect more boards as described above.

Ordering Guide
Product group Product name EAN 40* S-Unit* (pcs)
LINEARlight LM01C 2700K LM01C-LIN-280-827-500 4052899 135918 50
LINEARlight LM01C 5700K LM01C-LIN-280-857-500 4052899 125353 50
LINEARlight LM01C 6500K LM01C-LIN-280-865-500 4052899 125384 50
CONNECTsystem LM-2PIN 4008321 908629 500
CONNECTsystem LM-2CONN 4008321 908643 500
CONNECTsystem LM-2CONN-50 4008321 908667 500
LINEARlight Optics 6x1 OS-OP6x1 4052899 130265 600

* EAN: Ordering number per single sale unit (SPQ)


* S-Unit: Modules / accessory number per shipping unit

Note: Typical performance data are subject to change without any further notice, particularly as LED technology evolves.

Sales and Technical Support

OSRAM Asia Pacific

16th Floor, China Resources Building Sales and technical support is given by the
local OSRAM subsidiaries.
26 Harbour Road, WanChai, Hong Kong On our world wide homepage all OSRAM
subsidiaries are listed with complete address
and phone numbers.
www.osram.com

LM01C – Nov. 2013 V2.2 Page 4 of 4

You might also like