You are on page 1of 2

NetSure 731 A41 Hybrid

Embedded High-Frequency Switch Mode Power System

Key Features
 Optimize space utilization and
reduce installation cost due to its
highly compact size and fully
integrated components
 Up to 12kW rectifier capacity at
95.5% using High efficiency
rectifier, R48-3000e3 and
providing up to 95% system
efficiency.
 Up to 12kW solar converter Netsure 731 hybrid solar subrack is designed by Emerson
(MPPT) capacity, S48-3000 with Network Power to provide reliable -48V power supply to
perfect MPPT function providing unreliable or off-grid telecom sites in the access network. The
maximum power track efficiency system is designed to work with any combination of energy
99.5% sources (mains, diesel generator, solar panel) to keep the
 Equipped with AC surge battery within optimal operating conditions.
protection, DC surge protection
 Provides fully front access
rectifier slots for easy slot in of
hot-pluggable rectifiers and
controller. Easy for operation and
maintenance
 Battery management, which
prolongs the working life of
battery
 Provide multiple communication
ports such as RS232, Ethernet
port, dry contacts, etc, for flexible
networking to achieve remote NetSure 731 A41 Hybrid
monitoring
 Multiple energy sources: mains, Netsure 731 A41 Hybrid
diesel generator, solar panels, System Capacity 12kW rectifier system, 12kW solar system
battery Controller M830B
 Diesel generator start/stop Rectifier
Solar MPPT
Max: 4x3000e3
Max 4xS48-3000
functionality based on battery
SoC or daily fixed time schedule AC distribution (AC
1x63A/4P
input)
Solar Input 4x63A/1P
Application Battery Capture 2×125A/1P
DC BLVD 2x63A, 4x32A, 2x16A
 Power supply for LTE in-building distribution LLVD 2x32A, 2x16A
solutions C-level lightning protection at AC side, lightning
Lightning Protection
 Power supply for FTTx protection at DC side and signal side
3 alarm inputs, 4 alarm outputs (8 alarm outputs
broadband multi-solutions Dry Contact
is optional )
 Power supply for macro station Optional Top Cover, Temperature Sensor, Battery Rack
and outdoor cabinet
NetSure 731 A41 Hybrid
Embedded High-Frequency Switch Mode Power System

Rectifier & Solar MPPT


Configuration R48 - 3000e3 S48-3000 MPPT
Efficient Module Normal:R48-3000e3 Normal: S48-3000 MPPT
Electric Parameter Description
Input Voltage 85Vac~300Vac 58Vac~150Vac
Power Factor/MPPT
>0.99 for 50%-100% load 99.5%
Precision
Efficiency 95.5% > 98%
Output Voltage -42Vdc -58Vdc -42Vdc -58Vdc
Output Current 62.5A@-48VDC 61 A
Nominal Voltage -48 Vdc -48 Vdc
Operation Temperature -40°C~+70°C,-40°C~+158°C -40°C~+75°C

Controller M830B
Model M830B
Display 128 x 160 Pixels TFT LCD
Communication Interface RS232, RS485, Ethernet, USB
IPv4, IPv6, HTTPS, SNMP V 2/ V 3, EEM,
Protocol
SocTpe, Rsoc, Mod Bus
2 battery currents, 1 load current, 1 bus
voltage, 2 battery voltages, 3 temperatures,
Analog
1 fuel level sensor and much more with
Input additional interface boards
1 input for status of surge protective device
Digital auxiliary contacts, 12 load fuses, 6 battery
fuses, bi-stable contactor status
Outputs 3 LVD mono & bistable contactors

Mechanical Parameter Netsure 731 A41 Hybrid R48-3000e3 S48-3000 M830B


Structure 19 inches(W), 6U(H) 2 x 1U 3 x 1U 2 x 1U
Dimensions (W×D×H) (mm) 483 x 390 x 267 84.5 x 330 x 41 41.4 x 287 x 132.3 86x208x43.4
Weight (Kg) ~ 57kg 2kg < 3kg < 1 kg

www.EmersonNetworkPower.Asia
While every precaution has been taken to ensure accuracy and completeness herein, Emerson Network Power assumes no responsibility, and
disclaims all liability, for damages resulting from use of this information or for any errors or omissions. Specifications are subject to change without
notice. Emerson Network Power and the Emerson Network Power Logo are trademarks of Emerson Electric Co. or one of its affiliated companies.
All other names and logos referred to are trade names, trademarks, or registered trademarks of their respective owners.
©2015 Emerson Electric Co. All right reserved. FY15ENT_Netsure731A41Hybird_V1_DS