You are on page 1of 15

IB-9116

Electro Stimulation Instrument

Dear cus to mer,


Th anks for you r ch oo si ng o ur pro duct s.
For t he b est cap abi lity and s afety,p leas e read t he manu al b efore operat i on.
Pleas e r es erve the manu al fo r y our reference.
Brief introduction:

The perfect body shaping beauty instrument can dissolve the fat
inside the body including the grease around the bowels and inside the
abdomen. At the same time, it can decrease the excitability of the
sympathetic nerves and oxygen consumption of fat people. You can
lose weight in very short time due to the amassment of point
stimulation. This is the best traditional way of losing weight as your
perfect body figure can be kept after losing weight by using this
instrument.
The instrument is organically combined with frequency scan
circuit and microcomputer system to create stimulant bioelectricity,
and accurately holds the essentials of acupuncture of traditional
Chinese medicine to have regular deep-seated actuation and massage
so as to achieve expedite channels, regularize spirits, break over
lymph cycle system, remove internal toxin, improve body
microcirculation, promote metaboly, excite and redeploy body power
against disease, so that the bulk of fat cells can be diminished and the
skin can be frapped.

Functions and curative effect

Lose weight: ten days as a period of treatment and can lose 1-8kgs
Slim the body: ten days as a period of treatment and the waistline can
shorten 2-9centimetres
Enhance the breast:twenty days as a period of treatment and the breast
can be enhanced 1-3 centimetres
Function: losing weight, slimming the body, Enhancing the breast and
physical therapy
Advantages: low-frequency for losing weight and middle-frequency
for flapping the skin. The waist line can shorten 1-2cm
by instant treatment.

Instruction of panel

1.Frequency adjust
2. Working time adjust (down)
3. Program select (1-9)
4. Working time adjust (up)
5. Power (on/off)
6 –15. Frequency intensity adjust
16.LCD display
17. Electro stimulation outputs
18. Elastic band
19. Electro patch
20. Patch wire
21. Breast patch
22. Self-stick patch
23.Main frame
a. Frequency display
b. Time display
c. Program display

Procedure instruction:

Program 1: Low frequency (Superficial layer) lipolytic biological


stimulation

Function: Lipolytic biological stimulation directly acts on


lipocyte, which will decompose the body fat from
lipocyte by enhancing its permeability.
Application: Applying on any part of body, especially on localized
obesity.

Program 2: Activetype (deep level) lipohistiodieresis biological


stimulation

Function: This kind of stimulation can evoke the titanic


contraction of musculature to produce kreatine so as to
break down and waste body fat.
Application: Applying on deep level body fat.

Program 3: Deep level combustion and firmness biological


stimulation
Function: Impulse width and frequency of this kind of
stimulation is larger than the above two, which can
strengthen the stimulation to muscle fibre, then to more
fully waste deep level body fat.
Application: Applying on cellulite, the effect is obviously.

Program 4: Activating (firming) biological stimulation


Function: This kind of stimulation can fasten the inner cell
exchange of substance and synthesis of protein, so as
to improve the activity of nerve structure to act on
deposition.
Application: Applying on sagging skin.

Program 5: Firming up muscle (reinforcing firming) biological


stimulation
Function: Impulse width and frequency of this kind of
stimulation is larger than program 3, which can
strengthen the homomallous stimulation to muscle fibre,
then to more fully waste deep level body fat.
Application: Applying on cellulite, the effect is obviously.

Program 6: Continuous deep level weight–losing (de-toxin and


combustion) biological stimulation
Function: This is intermediate frequency stimulation, which can
continuously stimulate the deep level muscle
thousands times to expand the lymphatic vessel and
strengthen lymph circulation as to remove hydrolytic
fatty acid and internal toxin
Application: Applying on lymph circulation disorder, hydrocele
obesity. The de-toxin effect is obviously.
Program 7: Intermittent wave (beautifying breast and hip)
biological stimulation
Function: This stimulation is similar with program 4, but the
different is the wave of this kind is intermittent,
which provides rest for the muscle to facilitate the
body fat accumulating.
Application: Applying on body building,, sagging skin., breast
flat and small.

Program 8: Sine modulation wave and intermediate


frequency biological stimulation

Function: This stimulation can enhance permeability of cells


to fasten the inner cell exchange of substance, which
expands the lymphatic vessel and strengthen lymph
circulation as to remove hydrolytic fatty acid and
internal toxin and tone up the muscle.
Application: Applying on sagging breast, hip and skin and
de-toxin .

Program 9: Recurring program 1 to program 8.

Operation Instruction

1. Adjust each output to no output state.


2. Check and connect power showed as the
picture
Then turn on the switch.

3. Press the Start /Pause key , and the device starts working,.

4. Press the Program Mode key ,select the program . And there

are nine kinds of program as 1.2.3.4..…….

5. Set the operation time by adjusting the TIME key.

6. Set the output intensity by rotating the buttons of 6-15 (showed on

the Panel)
7. In the operation process, if the function, time or intensity key should
be shifted, just press the corresponding key and the operation will
not be stopped.

Process of the treatment


1. Apply some gel or cream for losing weight on the electro patches
and fix them up with the flex on the part of the body.
2. Paste the patch on the parts of body as following:
Picture 1: Neck and Shoulder
Function: Stimulate the blood circulation on neck and shoulder which
can remove the fat and tire.
Picture 2: Neck and shoulder and arm
Function: Stimulate the blood circulation on neck, shoulder and arm,
which can open up to remove fat.

Picture 3: Breast
Function: Stimulate the blood circulation on breast. And stimulate the
development of the breast, which can adjust the secretion of the
Hormone.

Picture 4: Belly
Function: Stimulate the blood circulation on belly and remove the fat
and tone up the muscle on chest.

Picture 5 Back
Function: Stimulate the blood circulation on back and tone up the
muscle of the back, which can remove the excess fat and alleviate
fatigue.

Picture 6: Hip
Function: Stimulate the blood circulation on hip, which remove the
excess fat and tone up the muscle of the hip.

Picture 7: Arm
Function: Stimulate the blood circulation on arms and open up
channels which can remove the excess fat and tone up the muscle of
the arm.

Picture 8 Leg
Function: Stimulate the blood circulation on legs and open up
channels which can remove the excess fat and tone up the muscle of
the leg.

3. Turn on the power and choose the suitable produce.


(1) Applying on any part of body, especially on localized obesity.
(2) Applying on deep level body fat.
(3) Applying on cellulite
(4) Applying on sagging skin.
(5) Applying on cellulite
(6) Applying on lymph circulation disorder, hydrocele obesity
(7) Applying on body building,, sagging skin., breast flat and
small.
(8) Applying on sagging breast, hip and skin.

4. Adjust the time by pressing the button of Time Adjust .


(0-60minutes)
Weight loss: 30-40 minutes everyday 15times one treatment.
Breast care: 20-30 minutes once one day 15-30 times one treatment

5. Turn on the button to adjust


intensity according to the feeling of the client. Then

adjust the four frequency modes, there are four modes


showed as .
6. During the treatment you can switch the button of function, time
and intensity at will.
7. Proper intensity: As the tolerance of electricity is different among
different people, for different customers the applying electricity
intensity should be different, and the following is intensity types:
ⅠSense limit:Feel the electricity

ⅡConstringency limit:Muscles begin to constriction.


Ⅲ Tolerance limit:Body can be tolerant the electricity

Part of the body Proper dose

Neck and shoulder Sense limit


Leg Constringency limit, Tolerance limit
Arm Constringency limit, Tolerance limit
Belly Constringency limit, Tolerance limit
Breast Constringency limit
Back Constringency limit, Tolerance limit
Hip Constringency limit, Tolerance limit

8. After the treatment, please ensure time display is 0 and the


output should be turned off.
9. Clean and sterilize the patch and put them away.

Notice:
1. Please do not adjust the intensity too high.
2. If do Weight -losing, the intensity should be according to the
feeling of the clients.
3. If do breast care treatment please choose the low intensity.
4. Please clean the skin where the patch will be put on and make
sure the bottom of intensity is on 0.
5. Please smear the media which stops the electricity. Please smear
the media evenly avoid making the skin painful.
6. If there some problems with the skin please reduce the times of
the treatment.
7. During the treatment please adjust the intensity according to the
feeling of the client.
Taboo:
1. The people with the blood sick can not use this instrument.
2. The people whose skin has some problems can not use this
instrument.
3. The people with heart disease can not use it.
4. The people with the metal inside the body.
5. Pregnant woman can not use it.
6. The people with tumor can not use it.
7. This appliance is not intended for use by person (including
children) with reduced physical, sensory or mental capabilities,
or lack of experience and knowledge, unless they have been
given supervision or instruction concerning use of the appliance
by a person responsible for their safety.
8. Children should be supervised to ensure that they do not play with
the appliance.

Technology Parameter
Voltage: 110V 220V 230V 240V
Working frequency: 50Hz 60Hz
Power: 40W
Measurement: 55x38x20CM 103x55x46CM
Gross weight: 5Kg 25Kg

Accessories packing list


ITEM NAME UNIT QUANTITY REMARKS

Main Frame Set 1

Patch Wire Strip 10

Breast Patch Piece 2

Electro Patch Piece 20

Self-stick Patch Piece 2

Power Wire Strip 1

Elastic Band Strip 1

Fuse Set 2

Instruction Piece 1

Important Safety Notice

1. Please don’t disassemble the equipment or try to do some other


operation, which have not been indicated in our instruction. All the
repairing work should be done by our admitted professional
personnel

2. Please don’t assemble or operate this equipment while you are near
the water or your hands are wet. Don’t pour the liquid on it.
3. Please pull out the plug from the socket when you met such
conditions as below. And contact professional maintenance
Station.
a. The equipment touched liquid
b. The equipment has abnormal smell, smoking or loud and strong
noise.
c. Cable is broken
d. The equipment is fallen down and broken
4. Don’t put anything on the cables; don’t place the equipment at any
place where someone can step on the cable.
5. Please pull out the power cable after using it for your safety
6. Don’t put anything into the equipment’s jack, otherwise it may
cause fire or touch the electricity. If something enters the
equipment, please don’t pick it out by yourself, contract
distributor or our company immediately
7. Please don’t put the equipment on the anything that can’t stand
steadily, avoid it turns over and damage.