You are on page 1of 9
g [Mle ytsmyorvea ramen [x22... HOSPITAL. EXPANSION PROJECTS a eee DOCUMENT TRANSMITTAL FORM (OTF) z oor Project Osign, Construction, Eau Contract No: 18/2011/2012-11 Protea Bpralonlwanonance forthe = | Se a na a rn man —_— | 3+ Comply with all contract requirements and documents and manufacturer's instructions @ mewror erm EXPANSION PROJECTS. Method Statement for Modular System ___wsuizor | “pave:anatsois | Rev. co | B00no, Seu nasweaapo0e ext ——| Contract No: sazo¥s0%2i Project: Design, Constuction Equpment, Future and ‘Operational Mantonence forth New Al Sabah Hosp Design, Construction, Equipment, Furniture & Operational Maintenance for the Expansion of New Al Sabah Hospital for Ministry of Health, State of Kuwait METHOD STATEMENT FOR FIRE STOP WORKS Document No: SPML-NASH-MS-MQ-00006-Rev.1 38.01.2019 |—“rajeee Resident Manager Engineer Prepared by | Approved Rev| Date atc Mst-pisn Bonne coves Ki warren rosea comeonrrcscrs aa ‘Project: Design, Constuction, Equipment, Futur and ‘Operational Maintonanice forthe Rew AI Sabst Hopital (eee oe [TRNNO. MST.ALSASAH-M0005 Rev.0 Comments Sie DFM Comment ‘ATC Compliance 1 | Fellow the approved mati of Administration of | Woted omeureation and ares this transmital tothe Supervision Constant fe ree tots (£E skrre ) LT1; T . binistRY OF HEALTH sorisny Mideat aie, Ml MES.. wospIrat exeansion proseers f “DOCUMENT TRANSMITTAL FORM (TF) j | Contact No: s8/20112012-44 Fearon Ghrtcnl Sarasa ine | Furniture nd Operational usintnsnce forthe ew A Saban opt TRANS. NOs METAL SABA omg | REVO [Creme mcs Scien [Cr/ Aeneas TT approved wt common tomato asaya eo [Boner approned 10 Fier oa 3M METHOD STATEMENT FOR FIRESTOPPING MECHANICAL SERVICES. EE MirTHOD STATEMENT FOR FIRESTOPPING MECHANICAL SERVICES, METHOD STATEMENT FOR FIRE STOP WORKS New Sabah Hospital Expansion Project 3M. METHOD STATEMENT FOR FIRESTOPPING MECHANICAL SERVICES CONTENT 1.0 OBJECTIVE 2.0 SCOPE 3.0. MATERIAL 4.0 TOOLS OF APPLICATION 5.0 APPLICATION METHOD 6.0 APPLICATORS 7.0 SAFETY 3M METHOD STATEMENT FOR FIRESTOPPING MECHANICAL SERVI 1.0 OBJECTIVE To define the method of closing the fre rated wallslab opening for mechanical ‘Services using fire stop materials to retain the itegrlty of ie barirs, 2.0 SCoPE ‘The gaps provided in the fre rated slab around mechanical services will be sealed with fie resistant material, 3.0 MATERIAL ‘Anproved 3h fre stop material as recommended by the authorizes distibutor 1.3M™ Fire Barter IC 15WBe Standard or Buk Caulk Gun Rechargeable Caulk Gun Putty Knife, Trowel or equivalent Clean Tools wth water Damming: mineral Woo! 2. 9M™ Intoram™ Utra GS For Cutting: Utity Knife Industial Razor Blade Heavy Shears (Scissors) For Applicaton: Filament Tape 3) somes: seb L Ses 3M. METHOD STATEMENT FOR FIRESTOPPING MECHANICAL SERVICES Mimi STATEMENT FOR FIRESTOPVING MECHANICAL SERVICES, 4.3M™ Fire Barrier Mortar ‘Buckets/Mixing Containers Power or Hand Mixing Tools, Sti Sticks, Trowel Rigid Damming 5.0 Method: ‘A. The slab openings for Non motalic pipes size 2 inches and 4 inches to be Sealed with Fit stopping sealant for the gap provided between the sleave and the pipes. 8B. Pipe sleeves to be provided in slab penetration for drainage ripes, leaving a ‘G9p of 2" between the pipe and the sleeve. C. Following procedure will be followed for sealing of the gap for diferent ') Non Metalic Pipes 2 Inches - The annular gap between the pipes and sleeves fushed with the service will be filed up with mineral wool of ‘min 64 Kgim? and will be sealed with 3M IC 15WB Intumescent sealant . The depth of sealant will be minimum?/2° (13 mm). For the Pipe size2 Inch. ») Non Metalic Pipes 4 Inches: - The annular gap between the pipes and sleeves will be filed up with 3 layers of 3M Ullra GS Wrap stip ‘around the pipe, remaining gap wil be filed with mineral woo! of min 64 Kain as backup, 3m Fire Barrier Mortar mixed witk water will be ‘SM. METHOD STATEMENT FOR FIRESTOPPING MECHANICAL SERVICES SS METH0® STATEMENT FOR FIRESTOPPING MECHANICAL SERVICES, Poured over the top to seal the Pipe opening Mortar Thickness is kept 0:3" minimum, 6.0 Applicators All frestopping applicator to have completed training ccurses covering installation of specified material by the authorized 3M dealer 7.0 Sefety: Safety equipment ~ Hard hats, safety glasses, safety shoes, gloves and ‘veras to be wom at al times,

You might also like