You are on page 1of 5

DATA SHEET

SLBt
CLASS CLASS
RAL 7035 IP66 IK09 max 5 kg I II

Product information Installation and maintenance


Introducing Tungsram’s latest LED road and street fixture, the Mounting options:
SLBt, which makes the advantages of outdoor LED lighting • Side mount bracket ø35mm-60mm
available for everyone, even those on tight budgets. Designed • Post top bracket ø48mm-76mm
to replace 35-100W HID and 24-36W CFL fixtures, the SLBt is • Universal coupler side ø35mm-76mm
a great LED solution for minor roads, residential streets and • Universal coupler post ø35mm-76mm
other public spaces where modest levels of illumination are • Universal Coupler can be adjusted -15°,-10°, -5°, 0°, +5°,+10°,
required. +15° by 5° degree steps
• Recommended mounting height: 4-15m
Application areas • Weight: 5 kg
• Only two hand-tools required for installing the fixture
• Storage temperature up to 85ºC.
Pedestrian street Car park • Ambient temperature from -40ºC to +35ºC

Street & residential road lighting Optics


Available photometric distributions:
• Narrow Asymmetric – medium (B, B2, B5)
Driver features • Asymmetric – short (C, C5)
• Asymmetric forward – very short (D)
• Electronic, dimmable driver: Dali, CLO and dynadim from • Asymmetric – medium (E, E2, E5)
15-72W • Forward asymmetric – medium (F, F5, G2)
• Minimum dimming level 15W • Narrow asymmetric – short (N)
• Narrow asymmetric with backlight – short (P, P5)
• Narrow asymmetric – medium (R)
• Narrow asymmetric – medium (S)
Structures and materials • Asymmetric – short (T)
• Housing material: die-cast aluminium body, corrosion • Asymmetric – medium (U)
resistant screws and brackets • Pedestrian cross walk (X5, Z5)
• Optic material: coated polycarbonate or aluminium • Symmetric – medium (Y5)
• Colour: RAL7035
• Optical cover: UV stabilized polycarbonate Rated colour rendering index: >70
Rated correlated colour temperatures: 2700K, 3000K, 4000K
S/P rating for: 2700K - 1.09, 3000K - 1.33, 4000K - 1.56
ULOR: 0
Performance Rated initial chromaticity co-ordinate values for 2700K, 3000K,
4000K:
• Rated luminous flux range: from 1220 to 8190 lm at 4000K • CIE(x=0.4578, y=0.4101) 5SDCM
• Rated luminaire efficacy: minimum 120 lm/W at 4000K • CIE(x=0.43, y=0.403) 5SDCM
• Photometric code: 727/559, 730/559, 740/559 • CIE(x=0.38, y=0.38) 5SDCM
• Rated median useful life and the associated rated LM factor:
L90B50 > 103.000 hours Electrical
• Rated median useful life and the associated rated LM factor:
L80B10 > 215.000 hours Input voltage and frequency: 220-240V, 50-60Hz
• Rated abrupt failure value < 10% at 100.000 hours Class I + Class II
• Lumen maintenance code: 9 Surge protection: 10kV
• Rated ambient temperature (tq) related to performance Rated input power: 15W to 72W
for a luminaire: 25°C
• Rated median useful life and the associated rated LM factor:
L80B50 > 218.000 hours
Definitions and tolerances according to IEC62722-2-1:2014
Standards and regulation Other options available
CE, ENEC, Directive 2014/30/EC, 2014/35/EC, 2009/125/EC Precabling, extra surge protection up tp 10kV/5kA, daylight sen-
1194/2012/EU, 2011/65/EC, EN 60598, EN 62471, EN 55015, sor
EN 61000, EN 62493, EN 61547.

Typical photometrical features


105° 105° 105° 105° 105° 105°

90° 90° 90° 90° 90° 90°

75° 75° 75° 75° 75° 75°

60° 400 60° 60° 60° 60° 60°


400 320

600
45° 45° 45° 45° 45° 45°
600 480
800

800 640
1000

30° 15° 0° 15° 30° 30° 15° 0° 15° 30° 30° 15° 0° 15° 30°
cd 1000 lm cd 1000 lm cd 1000 lm
C0 - C180 C90 - C270 C5 - C185 C0 - C180 C90 - C270 C10 - C190 C0 - C180 C90 - C270 C15 - C195

B B2 B5

105° 105° 105° 105° 105° 105°

90° 90° 90° 90° 90° 90°

75° 75° 75° 75° 75° 75°

60° 200 60° 60° 60° 60° 300 60°


400

450
45° 45° 45° 45° 45° 45°
600
400 600

800
500 750

30° 15° 0° 15° 30° 30° 15° 0° 15° 30° 30° 15° 0° 15° 30°
cd 1000 lm cd 1000 lm cd 1000 lm
C0 - C180 C90 - C270 C85 - C265 C0 - C180 C90 - C270 C70 - C250 C0 - C180 C90 - C270 C35 - C215

C5 C D

105° 105° 105° 105° 105° 105°

90° 90° 90° 90° 90° 90°

75° 75° 75° 75° 75° 75°

400 200
60° 60° 60° 400 60° 60° 60°

600 300
600
45° 800 45° 45° 45° 45° 400 45°

800
1000 500

1000
1200 600

30° 15° 0° 15° 30° 30° 15° 0° 15° 30° 30° 15° 0° 15° 30°
cd 1000 lm cd 1000 lm cd 1000 lm
C0 - C180 C90 - C270 C10 - C190 C0 - C180 C90 - C270 C10 - C190 C0 - C180 C90 - C270 C90 - C270

E E2 E5
105° 105° 105° 105° 105° 105°

90° 90° 90° 90° 90° 90°

75° 75° 75° 75° 75° 75°

60° 400 60° 60° 200 60° 60° 200 60°

600 300
45° 45° 45° 45° 45° 45°

800 400 400

1000 500 500

30° 15° 0° 15° 30° 30° 15° 0° 15° 30° 30° 15° 0° 15° 30°
cd 1000 lm cd 1000 lm cd 1000 lm
C0 - C180 C90 - C270 C25 - C205 C0 - C180 C90 - C270 C30 - C210 C0 - C180 C90 - C270 C80 - C260

F F5 G2

105° 105° 105° 105° 105° 105°

90° 90° 90° 90° 90° 90°

75° 75° 75° 75° 75° 75°

60° 60° 60° 200 60° 60° 60°


800 400

300
45° 45° 45° 45° 45° 45°
1200 600
400

1600 800
500

30° 15° 0° 15° 30° 30° 15° 0° 15° 30° 30° 15° 0° 15° 30°
cd 1000 lm cd 1000 lm cd 1000 lm
C0 - C180 C90 - C270 C20 - C200 C0 - C180 C90 - C270 C90 - C270 C0 - C180 C90 - C270 C75 - C255

N P5 P

105° 105° 105° 105° 105° 105°

90° 90° 90° 90° 90° 90°

75° 75° 75° 75° 75° 75°

60° 300 60° 60° 400 60° 60° 300 60°

450 600 450


45° 45° 45° 45° 45° 45°

600 800 600

750 1000 750

30° 15° 0° 15° 30° 30° 15° 0° 15° 30° 30° 15° 0° 15° 30°
cd 1000 lm cd 1000 lm cd 1000 lm
C0 - C180 C90 - C270 C60 - C240 C0 - C180 C90 - C270 C5 - C185 C0 - C180 C90 - C270 C62.5 - C242.5

R S T
105° 105° 105° 105° 105° 105°

90° 90° 90° 90° 90° 90°

75° 75° 75° 75° 75° 75°

200
60° 400 60° 60° 60° 60° 60°

600
45° 45° 45° 45° 45° 400 45°
480
800
500

640
1000
600

30° 15° 0° 15° 30° 30° 15° 0° 15° 30° 30° 15° 0° 15° 30°
cd 1000 lm cd 1000 lm cd 1000 lm
C0 - C180 C90 - C270 C12.5 - C192.5 C0 - C180 C90 - C270 C120 - C300 C0 - C180 C90 - C270 C60 - C240

U X5 Y5

105° 105°

90° 90°

75° 75°

60° 200 60°

45° 45°

400

500

30° 15° 0° 15° 30°


cd 1000 lm
C0 - C180 C90 - C270 C35 - C215

Z5

Dimensions (mm)

422 386
123
151

72
111
103

241

191

347
Order logic
IEC
Front Power CCT
Name Gen. Optics Control Accessories Protection Precabling Mounting Color
Glass (W) (K)
Classes

B
C
D ST -
E Standard type S60 -
F N- Side mount bracket
M3 -
No control 42-60mm
N Minicell 35lux*
P P76 -
D - DALI SP - Post top bracket
R 15 Extra Surge 48-76mm
protection
S 20 Y - DynaDim
N- U35 -
T 30 F - Fuse No precabling Universal coupler
27-2700 NL-
U 35 C1 - Class I 35-42 mm R7035
F-Flat LS -
SLBt 3 30-3000 No control with PXX-
Glass B2 40 7 pin NEMA
CLO C2 - Class II Precabling U50 - RXXX
40-4000 socket* **
B5 50 with XX me- Universal coupler
ters 42-55 mm
C5 55 DL- LSP -
7 pin NEMA
E2 70 Dali with CLO U60 -
socket Universal coupler
E5 + 50-60 mm
YL - Surge
F5 protection* **
DynaDim with U76 -
G2 CLO Universal coupler
SR -
P5 55-76 mm
Smart ready
X5 connector*
Y5
Z5

Example: SLBT/3/F/B/20/40/N/ST/C1/N/S60
* Marked constructions are not available with C2 IEC protection class
** LS and LSP variants are IP65 and IK07

We in Tungsram Operations Kft. are constantly developing and improving our products. For this reason, all product descriptions in this catalogue are intended as a general
guide, and we may change specifications from time to time in the interest of product development, without prior notification or public announcement. All descriptions in
this publication present only general particulars of the goods to which they refer and shall not form part of any contract. Data in this guide has been obtained in controlled
experimental conditions. However, Tungsram cannot accept any liability arising from the reliance on such data to the extent permitted by law.
SLBt GEN3 Datasheet – April 2019 tungsram.com