Fire pump

selection chart

Horizontal split case


diesel driven installed
in the United States
or Territories
File No: f46.230
Date: march 18, 2013
Supersedes: f46.230
Date: june 5, 2009
contents
500 gpm 4
750 gpm 5
1000 gpm 6
1250 gpm 7
1500 gpm 8
2000 gpm 9
2500 gpm 10
3000 gpm 11
fire pump Horizontal split case
s e l ec t i o n c h a r t s diesel driven

h o r izo n ta l s p lit c a s e – d i e s e l d r i v e n

500 gpm
head listing suggested diesel(1)
pump size max bhp
psi ft ulc ul fm model rpm hp(2)

41 95 21 √ √ √
5×4×12hf ju4h–ufaeao 1760 37
45 104 23 √ √ √

50 116 29 √ √ √

55 128 32 √ √ √

60 139 34 √ √ √

65 151 37 √ √ √

70 162 39 √ √ √

75 174 42 √ √ √
ju4h–uf14 2800 70
80 185 47 √ √ √

85 197 47 √ √ √
5×4×10f
90 208 50 √ √ √

95 220 53 √ √ √

100 231 57 √ √ √

105 243 61 √ √ √

110 255 64 √ √ √
ju4h–uf14 3000 71
115 266 67 √ √ √

120 278 71 √ √ √ ju4h–uf14 3000 71

124 287 75 √ √ ju4h–uf24 3000 83

note:

Shaded areas indicate pump capacities which can be supplied by end suction fire pump.
See file f40.230 for end suction diesel driven selection charts.
(1) Engine selection is based on the most economical engine and pump speed.
Other speeds and engine may be available. Refer to pump curves and engine table file f43.720.
(2) Engine hp is only for installations up to 300ft elevation above sea level and ambient temperature of 77°f.
At higher elevations, and higher ambient temperatures, engine must be derated. See chart in diesel section file f43.720 p.3
Horizontal split case fire pump
diesel driven s e l ec t i o n c h a r t s

h o r izo n ta l s p lit c a s e – d i e s e l d r i v e n

750 gpm

head listing suggested diesel(1)


pump size max bhp
psi ft ulc ul fm model rpm hp(2)
45 104 31 √ √ √
ju4h–ufaea0 1760 37
50 116 6×5×12hf 35 √ √ √
55 128 39 √ √ √ ju4h–ufaee8 1760 64
60 139 43 √ √ √
65 151 47 √ √ √
70 162 6×5×9.5f 50 √ √ √ ju4h–uf14 2800 70
75 174 54 √ √ √
80 185 60 √ √ √
85 197 60 √ √ √
90 208 64 √ √ √
ju4h–uf14 3000 71
95 220 67 √ √ √
100 231 5×4×10hf 71 √ √ √
105 243 75 √ √ √
110 255 79 √ √ √ ju4h–uf24 3000 83
115 266 83 √ √ √
120 278 90 √ √ √
125 289 95 √ √ √ cfp5e–f10 2600 104
130 301 6×5×12mf 101 √ √ √
135 312 106 √ √ √
cfp5e–f20 2600 117
140 324 112 √ √ √
145 335 142 √ √ √
150 347 146 √ √ √
ju6h–ufadmg 2100 175
155 359 151 √ √ √
160 370 8×6×16f 156 √ √ √
165 382 172 √ √ √ ju6h–ufadmg 2350 175
170 393 175 √ √ √ ju6h–ufadmg 2350 175
176 407 180 √ √ √ ju6h–ufadng 2350 183

note:

Shaded areas indicate pump capacities which can be supplied by end suction fire pump.
See file f40.230 for end suction diesel driven selection charts.
(1) Engine selection is based on the most economical engine and pump speed.
Other speeds and engine may be available. Refer to pump curves and engine table file f43.720.
(2) Engine hp is only for installations up to 300ft elevation above sea level and ambient temperature of 77°f.
At higher elevations, and higher ambient temperatures, engine must be derated. See chart in diesel section file f43.720 p.3
fire pump Horizontal split case
s e l ec t i o n c h a r t s diesel driven

h o r izo n ta l s p lit c a s e – d i e s e l d r i v e n

1000 gpm

head listing suggested diesel(1)


pump size max bhp
psi ft ulc ul fm model rpm hp(2)
51 118 45 √ √ √
55 128 48 √ √ √
6×5×15f
60 139 53 √ √ √ ju4h–ufaee8 1760 64
65 151 57 √ √ √
70 162 73 √ √ √
8×6×10lf ju4h–uf24 3000 83
75 174 79 √ √ √
80 185 68 √ √ √ ju4h–uf14 3000 71
6×5×9.5f
85 197 74 √ √ √ ju4h–uf24 3000 83
90 208 92 √ √ √
ju4h–ufadj2 2350 99
95 220 98 √ √ √
100 231 100 √ √ √
105 243 6×5×12hf 106 √ √ √
ju4h–ufad5g 2350 118
110 255 112 √ √ √
115 266 118 √ √ √
120 278 124 √ √ √ ju4h–ufadp0 2350 13
125 289 120 √ √ √
6×5×12mf cfp5e–f30 2600 129
130 301 127 √ √ √
135 312 158 √ √ √
140 324 162 √ √ √
ju6h–ufadmg 2100 175
145 335 168 √ √ √
150 347 173 √ √ √
155 359 8×6×16f 179 √ √ √ ju6h–ufadng 2100 181
160 370 195 √ √ √ ju6h–ufadn0 2350 200
165 382 199 √ √ √ ju6h–ufadn0 2350 200
170 393 204 √ √ √
ju6h–ufadp0 2350 211
175 404 209 √ √ √

note:

Shaded areas indicate pump capacities which can be supplied by end suction fire pump.
See file f40.230 for end suction diesel driven selection charts.
(1) Engine selection is based on the most economical engine and pump speed.
Other speeds and engine may be available. Refer to pump curves and engine table file f43.720.
(2) Engine hp is only for installations up to 300ft elevation above sea level and ambient temperature of 77°f.
At higher elevations, and higher ambient temperatures, engine must be derated. See chart in diesel section file f43.720 p.3
Horizontal split case fire pump
diesel driven s e l ec t i o n c h a r t s

h o r izo n ta l s p lit c a s e – d i e s e l d r i v e n

1250 gpm

head listing suggested diesel(1)


pump size max bhp
psi ft ulc ul fm model rpm hp(2)
40 93 45 √ √ √
45 104 8×6×12.5hf 49 √ √ √ ju4h–ufaee8 1760 64
50 116 54 √ √ √
55 128 62 √ √ √
60 139 67 √ √ √ ju4h–ufaef2 2350 74
65 151 8×6×12.5mf 72 √ √ √
70 162 77 √ √ √
ju4h–ufadj2 2350 99
75 174 81 √ √ √
80 185 8×6×12.5hf 99 √ √ √
85 197 94 √ √ √ ju4h–ufadj2 2100 99
90 208 99 √ √ √
95 220 109 √ √ √ ju4h–ufad5g 2350 118
100 231 115 √ √ √
105 243 122 √ √ √ ju4h–ufadp0 2350 130
110 255 128 √ √ √
115 266 134 √ √ √
ju4h–ufadr0 2350 140
120 278 140 √ √ √
125 289 146 √ √ √
130 301 153 √ √ √
135 312 159 √ √ √ ju4h–ufadmg 2350 175
140 324 6×5×15f 166 √ √ √
145 335 173 √ √ √
150 347 180 √ √ √ ju4h–ufadng 2350 183
155 359 188 √ √ √ ju6h–ufadn0 2350 200
160 370 197 √ √ √ ju6h–ufadn0 2350 200
165 382 206 √ √ √ ju6h–ufadp0 2350 211
170 393 215 √ √ √ ju6h–ufadq0 2350 226
175 405 216 √ √ √ cfp7e–f40 2600 219
180 416 223 √ √ √
cfp7e–f50 2600 234
185 428 232 √ √ √
190 439 239 √ √ √
cfp7e–f60 2600 249
196 453 249 √ √ √

note:

Shaded areas indicate pump capacities which can be supplied by end suction fire pump.
See file f40.230 for end suction diesel driven selection charts.
(1) Engine selection is based on the most economical engine and pump speed.
Other speeds and engine may be available. Refer to pump curves and engine table file f43.720.
(2) Engine hp is only for installations up to 300ft elevation above sea level and ambient temperature of 77°f.
At higher elevations, and higher ambient temperatures, engine must be derated. See chart in diesel section file f43.720 p.3
fire pump Horizontal split case
s e l ec t i o n c h a r t s diesel driven

h o r izo n ta l s p lit c a s e – d i e s e l d r i v e n

1500 gpm

head listing suggested diesel(1)


pump size max bhp
psi ft ulc ul fm model rpm hp(2)
50 116 64 √ √ √
ju4h–ufaee8 1760 64
55 128 71 √ √ √
60 139 8×6×12.5hf 78 √ √ √ ju4h–ufadj8 1760 86
65 151 90 √ √ √
ju4h–ufadj2 2100 99
70 162 97 √ √ √
75 174 88 √ √ √
ju4h–ufadj2 2350 99
80 185 8×6×12.5mf 95 √ √ √
85 197 102 √ √ √
90 208 109 √ √ √ ju4h–ufad5g 2350 118
8×6×12.5hf
95 220 117 √ √ √
100 231 8×6×12.5mf 144 √ √ √
ju4h–ufadw8 1760 144
105 243 8×6×16f 142 √ √ √
110 255 160 √ √ √
8×6×12.5hf
115 266 170 √ √ √ juah–ufadmg 2350 175
120 278 8×6×15mf 173 √ √ √
125 289 161 √ √ √ juah–ufadng 2350 175
130 301 169 √ √ √ juah–ufadmg 2350 175
135 312 176 √ √ √ ju6h–ufadng 2350 183
140 324 184 √ √ √
ju6h–ufadn0 2350 200
145 335 193 √ √ √
150 347 202 √ √ √
6×5×15f ju6h–ufadp0 2350 211
155 359 211 √ √ √
160 370 221 √ √ √ ju6h–ufadq0 2350 226
165 382 225 √ √ √
cfp7e–f50 2600 234
170 393 232 √ √ √
175 405 242 √ √ √
cfp7e–f60 2600 249
179 413 248 √ √ √

note:
Shaded areas indicate pump capacities which can be supplied by end suction fire pump.
See file f40.230 for end suction diesel driven selection charts.
(1) Engine selection is based on the most economical engine and pump speed.
Other speeds and engine may be available. Refer to pump curves and engine table file f43.720.
(2) Engine hp is only for installations up to 300ft elevation above sea level and ambient temperature of 77°f.
At higher elevations, and higher ambient temperatures, engine must be derated. See chart in diesel section file f43.720 p.3
Horizontal split case fire pump
diesel driven s e l ec t i o n c h a r t s

h o r izo n ta l s p lit c a s e – d i e s e l d r i v e n

2000 gpm

head listing suggested diesel(1)


pump size max bhp
psi ft ulc ul fm model rpm hp(2)
45 104 78 √ √ √ ju4h–ufadj8 1760 86
50 116 10×8×11hf 89 √ √ √
53 123 95 √ √ √ ju4h–ufad5g 1760 110
60 139 104 √ √ √
10×8×14hf
65 151 115 √ √ √
ju4h–ufadp0 1760 121
70 162 118 √ √ √
75 174 8×6×15hf 127 √ √ √
80 185 135 √ √ √ ju4h–ufadw8 1760 144
85 197 139 √ √ √
90 208 153 √ √ √ ju4h–ufady8 1760 157
95 220 156 √ √ √
ju6h–ufadmg 2100 175
100 231 166 √ √ √
105 243 177 √ √ √ ju6h–ufadng 2100 181
110 255 187 √ √ √
ju6h–ufadn0 2350 200
115 266 197 √ √ √
8×6×15mf
120 278 207 √ √ √ ju6h–ufadp0 2350 211
125 289 223 √ √ √ ju6h–ufadq0 2100 224
130 301 235 √ √ √ ju6h–ufadr0 2100 238
135 312 240 √ √ √ ju6h–ufadr0 2350 240
140 324 251 √ √ √
ju6h–ufads0 2350 268
145 335 262 √ √ √
151 349 275 √ √ √ ju6h–ufadt0 2350 275

note:
(1) Engine selection is based on the most economical engine and pump speed.
Other speeds and engine may be available. Refer to pump curves and engine table file f43.720.
(2) Engine hp is only for installations up to 300ft elevation above sea level and ambient temperature of 77°f.
At higher elevations, and higher ambient temperatures, engine must be derated. See chart in diesel section file f43.720 p.3
fire pump Horizontal split case
s e l ec t i o n c h a r t s diesel driven

10

h o r izo n ta l s p lit c a s e – d i e s e l d r i v e n

2500 gpm

head listing suggested diesel(1)


pump size max bhp
psi ft ulc ul fm model rpm hp(2)
80 185 176 √ √ √ ju6h–ufad58 1760 183
85 197 186 √ √ √ ju6h–ufadn0 1760 197
91 211 206 √ √ √ ju6h–ufadp0 2100 209
95 220 217 √ √ √ ju6h–ufadq0 2100 224
100 231 229 √ √ √ ju6h–ufadr0 2100 238
10×8×14hf
105 243 241 √ √ √
ju6h–ufads0 2100 260
110 255 252 √ √ √
115 266 268 √ √ √ ju6h–ufads0 2350 268
120 278 275 √ √ √
jw6h–ufadf0 2100 311
125 289 288 √ √ √
130 301 321 √ √ √ jw6h–ufadj0 1760 350
12×8×18f
135 312 335 √ √ √ jw6h–ufad70 1760 376

note:
(1) Engine selection is based on the most economical engine and pump speed.
Other speeds and engine may be available. Refer to pump curves and engine table file f43.720.
(2) Engine hp is only for installations up to 300ft elevation above sea level and ambient temperature of 77°f.
At higher elevations, and higher ambient temperatures, engine must be derated. See chart in diesel section file f43.720 p.3
Horizontal split case fire pump
diesel driven s e l ec t i o n c h a r t s

11

h o r izo n ta l s p lit c a s e – d i e s e l d r i v e n

3000 gpm

head listing suggested diesel(1)


pump size max bhp
psi ft ulc ul fm model rpm hp(2)
79 182 198 √ √ √
ju6h–ufadp8 1760 220
85 196 215 √ √ √
90 208 230 √ √ √ ju6h–ufad88 1760 237
95 219 245 √ √ √ ju6h–ufadr8 1760 250
100 231 262 √ √ √
ju6h–ufadw8 1760 282
105 243 12×8×18f 277 √ √ √
110 254 295 √ √ √ ju6h–ufadx8 1760 305
115 266 312 √ √ √ ju6h–ufad98 1760 315
120 277 328 √ √ √ ju6h–ufadj0 1760 350
125 289 344 √ √ √
jw6h–ufad70 1760 376
131 300 362 √ √ √

note:
(1) Engine selection is based on the most economical engine and pump speed.
Other speeds and engine may be available. Refer to pump curves and engine table file f43.720.
(2) Engine hp is only for installations up to 300ft elevation above sea level and ambient temperature of 77°f.
At higher elevations, and higher ambient temperatures, engine must be derated. See chart in diesel section file f43.720 p.3
toronto
23 bertrand avenue
toronto, ontario
canada
m1l 2p3
+1 416 755 2291

buffalo
93 east avenue
north tonawanda, new york
u.s.a.
14120 -6594
+1 716 693 8813

birmingham
heywood wharf, mucklow hill
halesowen, west midlands
united kingdom
b62 8dj
+44 (0) 8444 145 145

manchester
wenlock way
manchester
united kingdom
m12 5jl
+44 (0) 8444 145 145

bangalore
#59, first floor, 3rd main
margosa road, malleswaram
bangalore, india
560 003
+91 (0) 80 4906 3555

shanghai
no. 1619 hu hang road, xi du township
feng xian district, shanghai
p.r.c.
201401
+86 21 3756 6696

a r m s t r o n g i n t e g r at e d
established 1934 a r m s t r o n g i n t e g r at e d . c o m
tm

You might also like