You are on page 1of 3

PRODUCT DATA SHEET

SikaGrout®-295 IN
HIGH PERFORMANCE, ULTRA HIGH STRENGTH CEMENTITIOUS GROUT

DESCRIPTION CHARACTERISTICS / ADVANTAGES


SikaGrout®-295 IN is a one component, ultra-high ▪ Easy to use (ready to mix powder)
strength, cement based grout, with high mechanical ▪ Pumpable
strengths, specifically designed for use in the renew- ▪ Very good flow characteristics
able energy field, under metal bases and concrete ▪ High & Rapid strength development
structures. ▪ Excellent bond to Concrete
▪ No Segregation or bleeding
USES ▪ Very high mechanical strengths
▪ Expansive properties
SikaGrout®-295 IN may be used in areas where high ▪ Non-corrosive
mechanical strengths are required, such as : ▪ Not flammable, non-toxic
▪ Under wind turbine base
▪ Under bearing plates APPROVALS / STANDARDS
▪ Between Precast concrete segments
▪ To grout cavities, gaps and voids in concrete ASTM C 1107, EN196

PRODUCT INFORMATION
Packaging 30 kg bag
Appearance / Colour Grey powder
Shelf Life 6 months from date of production if stored properly in original,
unopened and undamaged sealed packaging
Storage Conditions Store dry at 40–95 °F (4–35 °C)
Protect from moisture. If damp, discard material.
Bulk Density ~1.2 kg/l (of fresh grout) at 20 ºC
Maximum Grain Size 3.35 mm down
Compressive Strength 1 Day 3 Days 7 Days 28 Days ASTM C 109
35 N/mm2 60 N/mm2 70 N/mm2 90 N/mm2 70mm Cube, +20°C

Modulus of Elasticity in Compression ~ 38’000 N/mm2


Tensile Strength in Flexure 1 Days 28 Days EN 196-1
3 N/mm2 9.5 N/mm2 40X40X160mm
Prism, +20°C

Product Data Sheet


SikaGrout®-295 IN
December 2018, Version 01.01
020201010010000223

1/3
Mixing Ratio For Flowable Consistency:
Water : Powder = 0.11 to 0.12 by weight (3.3 l to 3.6 l water per 30 kg bag).
Consumption ~2400kg/m3 at water : powder ratio of 0.11
Layer Thickness 20 mm minimum / 120 mm maximum
Ambient Air Temperature +10ºC minimum / +40ºC maximum
Substrate Temperature +10ºC minimum / +40ºC maximum
Pot Life ~ 90 minutes at +20°C
Pot life may vary depending upon the application temperature

SUBSTRATE QUALITY / PRE-TREATMENT CURING TREATMENT


▪ The concrete shall be thoroughly clean, free ▪ Keep any visible, exposed grout surfaces as small as
from dust, loose material, surface contamination and possible and protect from premature drying out by
materials which reduce bond or prevent suction or suitable measures (keep moist, cover with wet hessi-
wetting by the grout an fabric etc.)
▪ Delaminated, weak, damaged and deteriorated con-
crete and where necessary sound concrete shall CLEANING OF TOOLS
be removed by suitable means
▪ The concrete substrates should be pre-soaked ▪ Clean all tools and application equipment with water
with clean water continuously for 2 - 6 hours to en- immediately after use
sure a saturated surface dry condition throughout ▪ Hardened/cured material can only be mechanically
the operation removed
▪ The concrete “pull off” (tensile) strength should be
> 1.0 MPa FURTHER DOCUMENTS
▪ Install appropriate formwork. Immediately
▪ Use SikaGrout®-295 IN for grouting only; do not use
before pouring remove all excess or standing water
SikaGrout®-295 IN for patch repair work etc.
from within any formwork
▪ Ensure formwork is secure and watertight to prevent
▪ Steel, iron: Clean, free from oil or grease, rust
movement and leaking during placing and curing
and scale etc.
▪ Use chilled water for mixing in case of high ambient
MIXING temperature
▪ Use hot water for mixing in case of very low ambient
▪ SikaGrout®-295 IN can be mixed with a low speed temperature
(<500 rpm) hand drill mixer to avoid entraining too ▪ Depending on requirements and site conditions the
much air. Mix only full bags for best results addition of dry, single size and clean aggregates is
▪ Pour the recommended water in a suitable possible. Trials are recommended to confirm suitabil-
mixing container. While stirring slowly, add the ity of aggregates to be used
powder to the water and mix thoroughly at least for ▪ For additional technical information on SikaGrout®-
5 minutes 295 IN or other grouting materials contact the tech-
▪ Add additional water within the mixing time if neces- nical services department
sary to the maximum specified amount to adjust the
grout to the required consistency BASIS OF PRODUCT DATA
▪ Dependent on the desired consistency and
flow properties, the mixing ratio can be adjusted. All technical data stated in this Product Data Sheet are
Don’t use concrete tilting mixer based on laboratory tests. Actual measured data may
▪ Do not mix more grout, which cannot be used vary due to circumstances beyond our control.
within Pot Life
APPLICATION
▪ Pour grout immediately after mixing into the pre-
pared openings. Ensure that air displaced by
the grout can easily escape; otherwise entrapped air
will prevent full contact grouting
▪ Wet porous substrates to saturated surface dry con-
dition
▪ When grouting base plates etc., ensure that a con-
tinuous and sufficient head of pressure is
maintained to keep the grout flowing
▪ To make optimum use of the products
expansion properties, apply the grout as quickly as
possible (within max. 15 minutes)

Product Data Sheet


SikaGrout®-295 IN
December 2018, Version 01.01
020201010010000223

2/3
LOCAL RESTRICTIONS LEGAL NOTES
Please note that as a result of specific local regula- The information, and, in particular, the recommenda-
tions the declared data for this product may vary from tions relating to the application and end-use of Sika
country to country. Please consult the local Product products, are given in good faith based on Sika's cur-
Data Sheet for the exact product data. rent knowledge and experience of the products when
properly stored, handled and applied under normal
ECOLOGY, HEALTH AND SAFETY conditions in accordance with Sika's recommenda-
tions. In practice, the differences in materials, sub-
For information and advice on the safe handling, stor- strates and actual site conditions are such that no war-
age and disposal of chemical products, users shall ranty in respect of merchantability or of fitness for a
refer to the most recent Safety Data Sheet (SDS) con- particular purpose, nor any liability arising out of any
taining physical, ecological, toxicological and other legal relationship whatsoever, can be inferred either
safety-related data. from this information, or from any written recom-
mendations, or from any other advice offered. The
user of the product must test the product’s suitability
for the intended application and purpose. Sika re-
serves the right to change the properties of its
products. The proprietary rights of third parties must
be observed. All orders are accepted subject to our
current terms of sale and delivery. Users must always
refer to the most recent issue of the local Product Data
Sheet for the product concerned, copies of which will
be supplied on request.

Sika India Pvt. Ltd.


620, Diamond Harbour Road
Commercial Complex II
Kolkata - 700 034
Tel : +91 33 24472448
Fax : +91 33 23978688
Mail : info.india@in.sika.com

SikaGrout-295IN-en-IN-(12-2018)-1-1.pdf

Product Data Sheet


SikaGrout®-295 IN
December 2018, Version 01.01
020201010010000223