Professional Documents
Culture Documents
Electric Valve
Actuators
and Controls
Introduction Advantages
For more than 40 years, Bettis The Bettis TorqPlus, and the modular concept, offers its
Corporation has been recognized users significant advantages:
worldwide for providing industry
■ Compact Design – The actuators provide maxi-
with high performance pneumatic
mum torque output relative to its small design
and hydraulic valve actuators. The
addition of the Bettis line of TorqPlus housing.
electric actuators carries on the ■ Custom Control Standards – By offering an
tradition of product quality, innova- almost endless number of control and accessory
tion and service reliability. combinations, Bettis electric actuators can effec-
Bettis TorqPlus actuators are specifi- tively be designed to virtually any end use.
cally designed for quarter-turn ■ Modular Construction – The modular design
operating applications — ball, butterfly and plug valves; allows the actuators to be easily field modified
dampers; vents and similar uses. TorqPlus actuators are
and serviced. Accessory kits can be stored for
available in a wide range of output torques and operat-
future use without consuming a large amount of
ing speeds to fit your specific requirements.
storage space.
The Bettis Engineered Solution ■ High Strength Gearing – We precision-machine
our gears from hardened alloy steel, and run in
Most electric actuators in use today are designed to
meet a range of torque and speed requirements for use needle bearings. The result is efficiency, smooth
in industrial applications. Controls and optional acces- energy transfer, quiet operation and, best of all,
sories are often available, added at the factory while long service life.
being assembled. Heretofore, not much attention has ■ Low Maintenance – Permanent lubrication
been given to field upgrades, inventory modifications or reduces the need for scheduled maintenance. The
parts replacement during servicing. actuators are supplied with low temperature
The Bettis TorqPlus actuators, instead, provide its users lubricant, allowing the units to perform in tem-
with a unique modular approach. The actuators are peratures to -40°F (-40°C). All operational parts
manufactured with pre-tapped holes in the base plate are fully enclosed in the housing eliminating all
to accommodate a myriad of control and accessory contact with the environment.
components, available in more than 200 easy-to-install
■ Guaranteed Torques – As with other Bettis
kits to fit virtually every requirement imaginable. Kits
are available, depending on the actuator model, to add: actuators, we guarantee our published output
torque values. If any Bettis TorqPlus actuator fails
■ Heaters and thermostats to meet its specified torque output under normal
■ Potentiometers use, we will replace it.
■ Servo controls
■ Motor brakes ■ Duty Cycle – All Bettis actuators are rated for a
■ Positioners and transmitters duty cycle of at least 30% (one motor-on period
■ Control stations followed by two motor-off periods). Higher duty
■ Multi-turn operation cycles (up to 100%), which can allow for up to
■ PLC interface 1200 starts per hour, at normal ambient tempera-
tures are available.
All of the components can be added inside the CSA type
4/4x weatherproof housing or the CSA type 4/4x, 7 and
9 weatherproof /explosion proof housings.
TYPICAL SPECIFICATIONS
©2002
© 2013Emerson.
Emerson.All
Allrights
rightsreserved.
reserved. 06-13
5M/07-12 Bulletin #81.20
DESIGN AND CONSTRUCTION
2 7
1
10
4 6
8
9
(EM-500 Series)
These very rugged and versatile electric actuators take easy plus efficient actuator installation.
full benefit of precision-machining which allows every
5. Capacitors. Used on all single phase AC units, each
model to provide maximum torque output relative to its
capacitor is peak voltage rated and of improved design
compact design configuration and contains a minimum
for maximum service life.
of parts to reduce vibration, lessen noise and resist
harsh service. Utilizing a combination of spur, worm and 6. Potentiometers. Precision mechanically linked to
planetary power gearing reduction systems, the Bettis actuator output drive for continuous position signaling.
TorqPlus actuators incorporate the most efficient, pow-
7. Position Indicator. Mechanically driven and easily
erful and appropriate drive design for service excellence.
viewed at top of actuator to insure or confirm actual
1. Motors. Available in Single Phase, 3 Phase and DC actuator and driven device position at all times (not
voltages, all motors are custom built for high-torque, available on compact Model EM-100).
low current draw and the highest duty cycle ratings
8. Dual Conduit Connections. Standard on all models,
offered. Single phase motors are capacitor run type and
except EM-100, allows full electrical code access of all
three phase are squirrel cage induction type both having
wiring through two NPT connections.
integral self resetting thermal cut-outs.
9. Torque Limit Switches. Standard for the high-
2. Brakes. Offered for all AC and DC motors, they are
torque 800-Series of Bettis TorqPlus actuators. These
capable of a holding force equal to the output torque
mechanical switches eliminate potential driven device
ratings of each actuator model.
damage due to over torque conditions in either direc-
3. Heater and Thermostat. Securely mounted and tion of operation.
appropriately sized to insure ample protection even in
10.Manual Override. Standard in all models except the
the worst environments (not visible in photo).
EM-100, manual override capability is offered in two
4. Terminal Strips. Standard in all models and allow forms; Declutchable and Direct Acting.
DESIGN AND CONSTRUCTION
7
4 2
6
5
8 10
11
12 13
(EM-800 Series)
Model EM-300 and the complete 500-Series 11. Enclosures. Made from high strength sand castings,
offer a Declutchable design which disengages the power enclosures are rated for applications in both Non-haz-
gear drive from the output shaft. Manual operation is ardous and Hazardous locations. As an option, the Bettis
accomplished by rotating the exposed output shaft TorqPlus is also available with a CSA Certified combina-
drive flats with an open end wrench after the position tion Hazardous and Non-hazardous enclosure for indoor
indicator knob is pulled up. Return to full automatic and outdoor protection in locations classified Class I and
operation is as easy as removing the wrench and lower- II, Groups C, D, E, F and G as defined in the National
ing the position indicator knob to allow the mechanism Electrical Code plus protects against wind-blown dust,
to re-engage upon application of power. Should power wind-blown rain, splashing water and hose-directed
be applied during manual operation, the declutchable water.
design will not allow the output shaft to rotate.
12. Output Drives are corrosion resistant. Female drives
The 800-Series offers a Direct Acting handwheel design are available in a variety of DIN/ISO 8-point sizes. Male
which allows completely safe operation at any time and drives are also available on models 300 and 500. The
with never more than 50 pounds of rim pull force. EM-800 series is provided with bored drive sleeve with
Operating independent of the motor but directly into double keyways.
the power gear drive, the handwheel does not rotate
13.Powder Coat Finish. A polyester external coating
during automatic operation of the actuator, requires no
developed to serve as both a high durability impact and
engagement action for manual operation and may be
chemical resistant finish. With up to 160 lb-in ASTM
rotated with or without power to the unit.
D2794 impact resistance, over 1000 hours ASTM B117
salt spray rating and 1000+ hours ASTM D2247 humidi-
ty resistance, this protective finish will stay in place and
do the job.
©2002
© 2013Emerson.
Emerson.All
Allrights
rightsreserved.
reserved. 06-13
5M/07-12 Bulletin #81.30
TorqPlusTM Electric Actuators MODEL EM-100
Torque 100 IN/LB – 350 IN/LB
OPTIONAL FEATURES
• Maximum of two additional single pole double
throw auxiliary limit switches
• Heater and thermostat
• Canadian Standards Association general purpose
for electrical certification available under file
#LR90062
• Standard 1KΩ potentiometer. Other ranges
provided upon request.
• Relay control
• Electronic proportional positioner for 4-20 mA,
1-5 VDC, or 0-10 VDC control input and 4-20mA
output signal
• Optional voltages
230 VAC 50/60 Hz single phase
12/24 VDC
24 VAC
STANDARD FEATURES
• Two year warranty
• Permanently lubricated gear train
• Stainless steel output drive sleeve
• Operating temperatures:
-40°F with heater activated, to +140° F
• Unidirectional motor with thermal overload pro-
tection and mechanical brake for 100 in/lb model
TorqPlusTM Electric Actuators MODEL EM-100
Torque 100 IN/LB – 350 IN/LB
Brake
Capacitor
Motor
Output Drive
Shaft
Limit Switch
Terminal
Strip
©2002
© 2013Emerson.
Emerson.All
Allrights
rightsreserved.
reserved. 06-13
5M/07-12 Bulletin #85.10
TorqPlusTM Electric Actuators MODEL EM-300
Torque 150 IN/LB – 600 IN/LB
OPTIONAL FEATURES
• 75% or 100% extended duty cycle motors
• Electromechanical brake for 15 second and 30
second units
• Standard 1KΩ potentiometer. Other ranges pro-
vided upon request.
• Relay control
• Electronic proportional positioner for 4-20 mA,
1-5 VDC, or 0-10 VDC control input and 4-20mA
output signal
• Optional voltages
230 VAC 50/60 Hz single phase
12/24 VDC
24 VAC
• Maximum of four additional auxiliary single
pole double throw auxiliary limit switches with
adjustable cams.
• Handwheel
• Canadian Standards Association general purpose
for electrical certification available under file
STANDARD FEATURES #LR90062
• Two year warranty
• Dual purpose weatherproof and explosion-proof
• Heater and thermostat installed in all actuators
enclosures are certified by Canadian Standards
• Case hardened steel spur gear train is permanently
Association for services: Class I Groups C,D,
lubricated
Division I; Class II Groups E,F,G Division I that
• Hardened steel drive shaft
conform to NEMA type 7 and 9
• Female DIN/ISO F04 output drive and bolt pattern
or male output drive
TorqPlusTM Electric Actuators MODEL EM-300
Torque 150 IN/LB – 600 IN/LB
Position Indicator
Output
Drive shaft Motor and Brake
Terminal Heater
Strip
O-Ring Seal
Capacitor
Travel-Stop
Dual Conduit Limit Switches
Connection
Bettis Electric
2500 Park Avenue West
Mansfield, OH 44906 U.S.A.
T 419-529-4296
F 419-529-4484
Website: www.EmersonProcess.com/Bettis
E-Mail: Info.Bettis.Electric@EmersonProcess.com
©2002
© 2013Emerson.
Emerson.All
Allrights
rightsreserved.
reserved. 06-13
5M/07-12 Bulletin #82.10
TorqPlusTM Electric Actuators MODEL EM-500
Torque 350 IN/LB – 1600 IN/LB
OPTIONAL FEATURES
• Electromechanical brake
• Standard 1KΩ potentiometer, other ranges pro-
vided upon request
• Electronic proportional positioner for 4-20mA, 1-
5 VDC, or 0-10 VDC control input, and
4-20mA output signal
• Relay control
• Optional voltages
220 VAC 50/60 Hz single phase
12/24 VDC
24 VAC
• Maximum of four additional single pole double
throw auxiliary limit switches with adjustable cams
• Handwheel
• Dual purpose weatherproof and explosion-proof
enclosures are certified by Canadian Standards
Association for services: Class I Groups C,D,
Division I; Class II Groups E,F,G Division I that
conform to NEMA type 7 and 9
STANDARD FEATURES • Canadian Standards Association general purpose
• Two year warranty
for electrical certification available under file
• Heater and thermostat installed in all actuators
#LR90062
• Hardened steel spur gear train is permanently
lubricated
• Hardened steel drive shaft
• Female DIN/ISO F07 output drive and F07/F10
bolt pattern or male output drive
TorqPlusTM Electric Actuators MODEL EM-500
Torque 350 IN/LB – 1600 IN/LB
Position Indicator
Brake
Motor Output
Drive Shaft
Potentionmeter
Terminal
Electronic
Strips
Proportional
Positioner
Capacitor
O-Ring Seal
©2002
© 2013Emerson.
Emerson.All
Allrights
rightsreserved.
reserved. 06-13
5M/07-12 Bulletin #86.10
TorqPlusTM Electric Actuators MODEL EM-800
Torque 2,000 IN/LB – 20,000 IN/LB
OPTIONAL FEATURES
• Dual purpose weatherproof and explosion-proof
enclosures are certified by Canadian Standards
Association for services: Class I Groups C,D,
Division I; Class II Groups E,F,G Division I that
conform to NEMA type 7 and 9
• Standard 1K potentiometer, other ranges provid-
ed upon request
• Electronic proportional positioner for 4-20 mA,
1-5 vDC, or 0-10 vDC control input and 4-20mA
output signal
• Optional voltages
220 VAC 50/60 Hz single phase
220 VAC 50/60 Hz 3 phase
• Relay control
• Maximum of four additional single pole double
throw auxiliary limit switches with adjustable cams
• Electromechanical brake
• Canadian Standards Association general purpose
for electrical certification available under file
#LR90062
STANDARD FEATURES
• Two year warranty
• Heater and thermostat installed in all actuators
• Case hardened steel spur gear train is permanent-
ly lubricated
• Operating temperatures:
-40° F with standard heater activated, to +140° F
• Single phase capacitor run motor with thermal
overload protection
TorqPlusTM Electric Actuators MODEL EM-800
Torque 2,000 IN/LB – 20,000 IN/LB
Motor
Terminal Strips
Capacitor
Travel-Stop
Limit Torque
Switches Limit Switches
O-Ring Seal
Direct
Acting
Manual
Override
Dual Conduit
Connections
Electronic
Planetary Proportional
Gearing System Positioner
©2002
© 2013Emerson.
Emerson.All
Allrights
rightsreserved.
reserved. 06-13
5M/07-12 Bulletin #84.10
TorqPlusTM Electric Actuators MODEL EM-SR5
Torque 300 IN/LB – 1,600 IN/LB
Motor
Output
Drive Shaft
Terminal
Strip
Capacitor
Heater &
Thermostat
O-Ring Seal
Limit Switch
Dual Conduit
Connections Adjustable
Spring Stop
DIN-ISO Mounting/
Female Drive
EM-SR5-90 with
Gear Reduction Box
©2002
© 2013Emerson.
Emerson.All
Allrights
rightsreserved.
reserved. 06-13
5M/07-12 Bulletin #88.10
Assembly Layout Drawings MODEL EM-050
7 1/2
5.00 CLEARANCE
FOR COVER REMOVAL
TALL COVER
#8-32 PHIL.
SHORT COVER PAN HEAD
6 3/4
(6) PLACES
5 1/2
1/2-14 NPT
CONDUIT ENTRY
SUPPLIED WITH
PLUG
7/8
2 1/4 1 5/8
2 3/16
5 1/4
1.002 1.169
501 .585
.561
X .63 DEEP (TYP.)
.556
1.392
.696
.713 ACROSS CORNERS MIN.
7 1/2
5.00 CLEARANCE
FOR COVER REMOVAL
TALL COVER
#8-32 PHIL.
SHORT COVER PAN HEAD
6 3/4
(6) PLACES
5 1/2
1/2-14 NPT
CONDUIT ENTRY
SUPPLIED WITH
PLUG
7/8
2 1/4 1 5/8
2 3/16
5 1/4
1.002 1.169
501 .585
.561
X .63 DEEP (TYP.)
.556
1.392
.696
.713 ACROSS CORNERS MIN.
1/2-14 NPT
CONDUIT ENTRY
WITH (2) PIPE
PLUGS SUPPLIED
7 1/2
6 13/32
1/2
1 1/2
3
1 1/4
.44
8 1/4
3 1/8
6 1/4
OPTIONAL MALE OUTPUT
.456
DIA.
45°
.584
TYP.
.750
.281
.437 SQ. X .50 DEEP (TYP.) FLATS CENTERED
.279
.433
Bettis Electric
2500 Park Avenue West, Mansfield, OH 44906 U.S.A. T 419-529-4296 F 419-529-4484
Website: www.EmersonProcess.com/Bettis E-Mail: Info.Bettis.Electric@EmersonProcess.com
©2002
© 2013Emerson.
Emerson.All
Allrights
rightsreserved.
reserved. 06-13
5M/01-02 Bulletin #85.15
Assembly Layout Drawings MODEL EM-500
EM-510
EM-520
6" MIN. CLEARANCE FOR
COVER REMOVAL
OPEN/CLOSE
INDICATOR
1/2-14 NPT
CONDUIT 1/4-20 S.S. CAPTIVE HEX
ENTRY WITH SLOTTED SCREW (8 TOTAL)
(2) PIPE
PLUGS
SUPPLIED 8
9 7/16
2 7/16
1 5/8
1.03
.90
OPTIONAL
MALE OUTPUT .626
1 5/8 2 1/2 3 3/4
.624
3 7/8
9 3/4 7 3/4
14
15 3/8
2 11/16
4 1/2
3/4-14 NPT
STANDARD 2 3/4
CONDUIT ENTRY
5 1/2 3 7/8
9 11/16
.254 X 1-1/2 DEEP 14
.250
2-PLACES
3/8-16 TAP X 3/4 DEEP 1/2-13 TAP X 7/8 DEEP
4-HOLES AS SHOWN 4-HOLES AS SHOWN
ON 3.250 DIA. B.C. ON 5.000 DIA. B.C.
1.385/1.378 DIA.
X 1-3/4 DEEP 1.503
1.498
2-PLACES
Bettis Electric
2500 Park Avenue West, Mansfield, OH 44906 U.S.A. T 419-529-4296 F 419-529-4484
Website: www.EmersonProcess.com/Bettis E-Mail: Info.Bettis.Electric@EmersonProcess.com
©2002
© 2013Emerson.
Emerson.All
Allrights
rightsreserved.
reserved. 06-13
5M/01-02 Bulletin #84.15
Assembly Layout Drawings MODEL EM-840
9 3/4 7 3/4
POSITION
4 1/8 3 3/4
INDICATOR
SEE NOTE 1
13 13/16
1 5/8
15 3/8
1/2 NPT
CONDUIT
ENTRANCES
8 3/8
1.414
.707
.585
1.170 .746 DIA.
.437
SQUARE X .50 DEEP
.433
NOTE:
F04 OUTPUT DRIVE VIEW 1) ADD 4.75 TO OVERALL DIMENSION FOR COVER REMOVAL
Bettis Electric
2500 Park Avenue West, Mansfield, OH 44906 U.S.A. T 419-529-4296 F 419-529-4484
Website: www.EmersonProcess.com/Bettis E-Mail: Info.Bettis.Electric@EmersonProcess.com
©2002
© 2013Emerson.
Emerson.All
Allrights
rightsreserved.
reserved. 06-13
5M/07-12 Bulletin #85.15
Assembly Layout Drawings MODEL EM-SR5-30
9 3/4 7 15/16
POSITION
4 1/8 3 3/4
INDICATOR
SEE NOTE 1
16 1/8
14 3/16
1.63
1/2 NPT
CONDUIT
ENTRANCES
9 1/8
3.50 DIA.
.748 SQUARE
1.392
.696
1.810
1/4-20 X .50 TAP
.905
(4) HOLES ON 1.968 DIA. BOLT CIRCLE
.696
3/8-24 X .79 TAP
1.392 .905
(4) HOLES ON 2.556 DIA. BOLT CIRCLE
FEMALE F05 OUTPUT MOUNTING 1.810
.561
SQUARE .63 DEEP
.556 NOTE:
F05 OUTPUT DRIVE 1) ADD 4.75 TO OVERALL DIMENSION FOR COVER REMOVAL
TorqPlusTM Electric Actuators 10 3/16 MODEL EM-SR5-90
DT BG3
12 9/16 POSITION INDICATOR
2 5/32
1 1/4
1 5/64 NOTE:
1) ADD 4.75 TO OVERALL
FOR COVER REMOVAL
1 5/64
2 5/32
.984
SQ
MALE OUTPUT
DRIVE SPRING RETURN PACK BEVEL GEAR ACTUATOR
Bettis Electric
2500 Park Avenue West, Mansfield, OH 44906 U.S.A. T 419-529-4296 F 419-529-4484
Website: www.EmersonProcess.com/Bettis E-Mail: Info.Bettis.Electric@EmersonProcess.com
©2002
© 2013Emerson.
Emerson.All
Allrights
rightsreserved.
reserved. 06-13
5M/07-12 Bulletin #85.15
INQUIRIES
Your inquiries for Bettis electric actuators can be processed efficiently when supplied with the information requested on this page.
Please use this page as a guide or submittal. If you need assistance, just ask your Bettis sales representative.
Customer Detail
Co. ________________________________________________ Job ________________________________________________
St. _________________________________________________ ___________________________________________________
City __________________________ State _______________ Item ____________ of ____________ Qty. _______________
Zip ________________________________________________ Mark / Tag ___________________________________________
Attn: _______________________________________________ ___________________________________________________
Valve Information
Mfg.: ____________________ Type: ___________________ Size: ____________________ Fig No. __________________
Rotation to CLOSE Position: • Clockwise • Counterclockwise as viewed from above (Std. is CW)
Maximum Sizing Torque, lb-in: ______________________________________________________________ (Safety factor included)
Actuator Information
Application: • Open-Close, 2 position, Service • Spring Return
• Jogging Multi-position Service • Fail CW
• Automatic Modulating Service • Fail CCW
Ambient Temperature: From ______________________ °F to ______________________ °F (-40°F to +140°F standard)
Nominal Operating Speed: ______________________ seconds per 90° (min-max range)
Motor Voltage: ______________________ Ph/___________ Hz/___________ VAC or VDC ______________________
Control Voltage: 1Ph/ ______________________ Hz/ ______________________ VAC (3-phase motor only)
Motor Duty Cycle: • 30% or • 100%
Total Number of Limit Switches: ______________________
Enclosure: • Type 4 CSA Certified for: non-hazardous indoor and outdoor locations to protect against wind-blown dust and rain,
splashing water and hose-directed water.
• Type 4 and 7 CSA Certified for: hazardous and non-hazardous indoor and outdoor locations to protect against
wind-blown dust and rain, splashing water and hose-directed water plus locations classified as Class I and II, Groups
C, D, E, F and G as defined in the National Electrical Code.
Integral Control Items (as required)
• Motor Brake (standard on EM-100 in 1Ph/60Hz/115VAC and all 800-Series with torques of 6,000 lb-in or greater)
• Multi-Turn Control: Set for ______________________ output turns (maximum of 30)
• Heater and Thermostat: 1Ph/ ______________________ Hz/ ______________________ VAC
• Three Position Operation: Set for ______________________ °/ ______________________ °/ ______________________ ° Stops
• Control Relay for: • normally clockwise or • normally counterclockwise
operation and operating on • 1Ph/______________________Hz/ ______________ VAC or • ______________ VDC
• Single Feedback Potentiometer: ______________________ Ohm/4 Watt
• Electronic Positioner: with • 4-20mA or • 0-10v or • 1-5v input and set for minimum output at
• clockwise or • counterclockwise position
• Electronic Position Transmitter: 4-20 mA output set for minimum output at • clockwise or • counterclockwise position
Separate Controls (as required)
• Manual Operating Station: • Type 4 or • Type 7 enclosure suitable for • wall mounting or • close coupling
• 1Ph/ ______________________ Hz/ ______________________ VAC to include:
• (_________) __________ Position Selector Switch marked __________ / __________ / __________
• (_________) Push Buttons marked ______________ / ______________ / ______________
• (_________) Lights marked and colored ___________-___________ /___________-___________ / ___________-___________
• (_________) Reversing Starter with 1 Ph/ ______________________ Hz/ ______________________ VAC control voltage
• Other ______________________________________________________________________________________________________
___________________________________________________________________________________________________________
___________________________________________________________________________________________________________
PRODUCT IDENTIFICATION
All Bettis TorqPlus Electric Actuators are manufactured Model: Model – Operating Speed – Enclosure Type –
with a product descriptive nameplate to insure its proper Motor Voltage – Configuration
application and continuing identification. The following
Torque: Rated Output Torque (lb-in)
represents the typical information included on the
nameplate and the meaning. Speed Sec 90: Seconds Per 90 Degrees Operation
Voltage: Motor Voltage (Ph/Hz/V)
LR Amps: Locked Rotor Amp Draw
Duty Cycle %: Effective Motor Run Capability
Serial: Individual Unit Serial Number
Mfg MM-YY: Month & Year of Unit Manufacturer
Enclosure: Rated Enclosure Type
DEFINITIONS
A.C. – Alternating current/voltage flowing in both Enclosure – The housing that surrounds the actuator’s operat-
directions alternately. ing parts. It can either be weatherproof or explosion proof.
The enclosure generally protects the electrical equipment
Amphere (Amp) – The unit of electric current, defined
from the environment and/or prevents an explosion within
in terms of the force between a pair of wires.
the enclosure from causing an external explosion.
Auxiliary Switch – A switch used to energize or
Hertz – Unit of frequency. Equal to one cycle per second.
de-energize other equipment (such as lights or pumps).
Supplied with its own cam to synchronize other equipment NEMA – Acronym for National Electrical Manufacturers
at any point of travel. Association.
Capacitor – A device having the property of storing an NEMA 4 – Rating designation for weatherproof enclosures.
electrical charge. Pliable gaskets are used on all metal-mating parts to prevent
moisture from entering.
CSA – Canadian Standards Association
NEMA 7 – Rating designation for enclosures suitable for con-
D.C. – Direct current/voltage which has a constant value rated
taining internal explosion without rupturing the enclosure
to zero. Steady current in one direction.
and without igniting surrounding gases in the atmosphere.
Duty Cycle – A mathematical calculation, expressed as a Metal-to-metal sealing is required in these rated products.
percent, to indicate available motor-on (running) time with-
Ohm – International unit of electrical resistance. The resistance
out endangering an over heating condition which would
in ohms between two points is defined by the DC voltage
terminate actuator operation.
divided by the DC current flowing between the points.
Using an actuator with a 10 seconds/90° operating speed
Reversing Starter – Its purpose is to connect, disconnect
and rated for a 50% duty cycle as an example, safe, non-
and reverse electricity to the motor. Also called reversing
interrupting operational periods would be: One 10 second
contractor, reversing controller or integral starter.
motor-on period followed by one 10 second motor-off
period. Total calculation time is 20 seconds of which 50% is Torque Limit Switches – Switches designed to monitor physical
motor-on time. variables or operating states and to open circuits in the
event of pre-set limits being exceeded.
Proper application of the duty cycle rating allows ample
time for the motor to dissipate internal heat and thereby Volt – Unit of potential difference or electrical potential. It
not cause a thermal overload cutoff. represents the amount of work done per unit charge in
moving a charge from one place to another.
©2002
© 2013Emerson.
Emerson.All
Allrights
rightsreserved.
reserved. 06-13
5M/07-12 Bulletin #81.50
TorqPlusTM Electric Actuators CONTROLS AND OPTIONS
Control Relay
• Provides a means of opening and closing a valve
Multi-Turn Operation with a variety of standard AC or DC maintained
control signals, such as 120 VAC, 24 VAC, 12 or
Option allows for multiple revolution on non-rising
24 VDC.
stem devices.
• Can be used for a fail close (or open) application
upon loss of the control signal. An internal coil
Electrical Mechanical Motor Brake (designed to be continuously energized) main-
Available for all actuator models. Brakes are employed tains the open signal to the actuator. When the
to eliminate motor run-on and to insure that the signal is removed, the coil de-energizes, causing
actuator and driven device maintain their position. the actuator to close.
Recommended applications include; all resilient seated
valves, valves with high flow rates, all modulating Additional Control Options
services and any time in which increased position • Up to 6 SPDT aux. limit switches
control is needed. • Electronic Transmitters (4-20mA output from a
DC transmitter or 4-20mA, 0-10V output from
Three Position Control an AC transmitter)
• Dual 1k ohm potentiometers
Typically used for multiported valves, operation can be
• Two speed operation (pulse timer package)
set for 0°-45°-90° or 0°-90°-180° with a stop at mid
• Unidirectional controls (up to 30 rotations)
position from one extreme or both.
• Control stations including buttons, lights, selector
switches
Potentiometers • 3-phase motor controls
Mechanically linked to the actuators output to provide • Three position operation (such as 0-45-90 or
a resistance signal proportional to the actuator’s and 0-90-180 degrees)
driven device’s position. Used to give continuous feed- • Torque seating for multi-turn and quarter turn
back to control panels, modulating position control and • Torque switch trip indication
other closed loop devices.
CONTROL STATIONS
Typical Options
Timer packages, control relays, special labeling, LED
lights, pad lockable switches, space heaters and
Canadian Underwriter Laboratory labels.
Additional options for 3-phase wall-mounted CS’s
include starters, control transformers, and overload
relays.
©2002
© 2013Emerson.
Emerson.All
Allrights
rightsreserved.
reserved. 06-13
5M/07-12 Bulletin #81.50
TorqPlusTM Electric Actuators SERVO POSITIONING SYSTEMS
Signal Wiring
Function Details
DIP SW FUNCTION:
1 - AUTO/MAN
Manual CW Manual CW
C1415 3
2
C1397
1
POWER
CONNECTIONS
POWER & CONTROL CONNECTIONS
©2002
© 2013Emerson.
Emerson.All
Allrights
rightsreserved.
reserved. 06-13
5M/07-12 Bulletin #00.00
Performance Data – Open/Close and Modulating Configurations
Available Torques, Operating Speeds, Motor Duty Cycles, Motor Voltages and Locked Rotor Amp Draws
Torque Expression: Inch-Pounds (in-lb) and Newton Meters (Nm).
Speed Expression: Seconds per 90° output rotation.
Heater & Thermostat ll AVoltages Standard Optional Standard Standard Standard Standard
Potentiometer 1k Ohm - 1/2% N.A. Optional Optional Optional Optional Optional
Electronic Proportional Positioner and/or N.A. Optional Optional Optional Optional Optional
Electronic Position Transmitter N.A. Optional Optional Optional Optional Optional
(1) When actuator is to be supplied with potentiometer, reduce number of available optional switches by two (2) except for 100 series.
(2) Brake is part of motor rotor
(3) Actuators were subjected to an endurance test of 6000 complete cycles at maximum rated torque.
(4) Hazardous locations classified as Class I and II Groups C,D,E,F and G.
Bettis Electric Mansfield, OH U.S.A. T 419-529-4296 Website: www.EmersonProcess.com/Bettis
©©2002
2013Emerson. rights reserved.
Emerson. All rights 5M/07-12 Bulletin #83.10
reserved.06-13
Bettis Electric
2500 Park Avenue West
Mansfield, OH 44906 U.S.A.
T 419-529-4296
F 419-529-4484
Website: www.EmersonProcess.com/Bettis
E-Mail: Info.Bettis.Electric@EmersonProcess.com Bettis France:
Bettis USA 25, Rue de Villeneuve
P.O. Box 508 Silic – BP 40434
Waller, TX 77484 U.S.A. 94583 Rungis, France
T 281-463-5100 T 331-49-797300
F 281-463-5103
North America Europe
F 331-49-797399
Website:
19200 www.EmersonProcess.com/Bettis
Northwest Freeway Asveldweg 11Bettis Int’l Sales Office:
E-mail: Info.Bettis@EmersonProcess.com
Houston TX 77065 7556 BR Hengelo (O)
USA Willich, Germany
The Netherlands
Bettis UK Ltd.
T +1 281 477 4100 Mumbai, India
T +31 74 256 1010
F3+1
Furze
281Court
477 2809 F +31 74 291 0938
Singapore
114 Wickham Rd. Important: Due to Emerson’s continuing commitment to engineered
product advancement, data presented herein is subject to change.
Middle East & Africa
Fareham, Hampshire PO 16 7SH Asia Pacific
P.O. Box 17033
T 44-1329-848-900 No. 9 Gul Road Certified dimensional drawings and wiring diagrams are available on
Dubai #01-02 Singapore 629361 request. Consult factory with model designation and serial number.
F 44-1329-848-901
United Arab Emirates T +65 6501 4600 BettisBulletin
Bettis Bulletin##10.10
10.10 Rev:
Rev:06-13
07/12
T +971 4 811 8100 F +65 6268 0028 ©
©2013
2002 Emerson. rights reserved.
Emerson. All rights reserved.5M/07/12
06-13
F +971 4 886 5465