Linde Material Handling

Pathfinder User Manual 39X


Series Machines
Linde Material Handling

Pathfinder-Table of Contents

Introduction ………………………………………………………………… Pages 1-5

Inputs and Outputs Traction……………………………………………… Pages 6-15

Inputs and Outputs Working Hydraulics............................................. Pages 16-24

Inputs and Outputs Display………………………………........................ Pages 25-27

Inputs and Outputs LOC………………………………………………….. Pages 28-29

Error Codes and Parameters Traction…………………………………… Pages 30-41

Error Codes and Parameters Working Hydraulics……………………… Pages 42-49

Error Codes and Parameters Display……………………………………. Pages 50-53

Error Codes and Parameters LOC………………………………………. Pages 54-57

Additional Pathfinder Slides for Specific Truck Types…………………. Pages 58-67

Offline Diagnostics…………………………………………………………. Pages 68-71

2
Linde Material Handling

Pathfinder – Information Page

This booklet has been put together to get a better understanding of Pathfinder Diagnostic Software. Using a
393 service base , we have broken down each screen in an attempt to clarify the Pathfinder program. Across
the 39x range of trucks, most of the adjustments, parameters are the same. For information regarding
391,392,394 machines , we have an additional sub section at the rear of this booklet which will cover the
screens that are specific to each model. This also acts as an update section. For future releases of Pathfinder
where a new screen has been added, the new screen will appear in the sub section so the main frame of the
booklet does not have to be altered.

In an attempt to provide as much information as possible, values such as milli amps, voltages and calibrated
values have been provided. These values have been taken from known good machines. Allthough every effort
has been made to keep this as accurate as possible, we must understand that this is a guide to understanding
the Pathfinder Diagnostic Program.

3
Linde Material Handling

Pathfinder

Linde Diagnostic System Software


for All 39X Model Machines
The diagnostic software will allow us to change parameters , monitor inputs and outputs and extract fault codes
from the machine. This booklet will take you through each section. To understand the 39X machine, you have to
know the software. It is a vital tool used in troubleshooting.

4
Linde Material Handling

Cables and Software

Pathfinder Software Disc

Cable Canbox To
Truck 3903820101

Cable, Computer To
Canbox3903820100
Canbox 3903605112

Engine Diagnostic Cables

3003652503 Diesel

3003652504 LP

5
Linde Material Handling
Pathfinder Linde Diagnostic System
Standard Settings
Guided Diagnostic

This screen is the first to be


displayed when you have
successfully connected to the
machine using Pathfinder. On
this page you can choose
between Diagnosis, Calibration,
Error Codes and Parameters,
Inputs and Outputs and
Troubleshooting.

Accelerator test is where we can


Select auto check the pedal group assembly
troubleshooting and click for wear. Follow the instructions
Select offline diagnostics start for a quick listing of provided.
then click start button for a current active fault codes.
full description of the fault
codes.
By selecting calibrate, we can
calibrate tilt angle, accelerator
pedals and joysticks. Follow
the instructions provided.

Start

6
Linde Material Handling
Inputs and Outputs-Current Codes
Traction
Traction Current Codes Inputs and Outputs

Displays current fault codes.


When you open Inputs and
Outputs it will automatically go
to Traction. To select Working
Hydraulics, simply click once
on the Working hydraulics tab.
Use the explanation of codes
to give you an insight as to
what the fault is.

If you require a full description


of the fault code, click on
Guided Diagnosis, click re-set
and then offline diagnosis's.
Then select either traction or
working hydraulics. Once the
codes are listed, scroll down to
your code number and click
once. The code description
and troubleshooting guide will
be displayed.

7
Linde Material Handling
Inputs and Outputs-Digital Inputs
Traction
Traction Digital Inputs Inputs and Outputs

Digital Inputs allows us to


monitor our inputs to the
controller. For example: seat
normally open (S4) is a 1.
When the seat switch is
closed, (S4) normally closed
will switch to 1 and (S4)
normally open will switch to 0.
The same applies for brake 1,
2,3. With park brake applied
the reading is 101, with brake
released it will read 010. Use
this section to check your
inputs.

The numbers to the left of the input function


represent the pin number on the controller, wiring
schematic and harness plug.

8
Linde Material Handling
Inputs and Outputs-Outputs
Traction
Traction Outputs Inputs and Outputs

In the Outputs section, we can


monitor the output signal from
the controller. The release
valve (1Y4 ) will switch from 0
to a 1 when the drive pedal is
depressed. The activation of
the gas cut off valve can also
be monitored. Zero is off and 1
is on.

Note: gas cut off valve


activation only applies to
machines where the gas
cut off valve is activated by
the LTC controller. New 39x
machines have the gas cut
off valve activated by the
Impco controller.

9
Linde Material Handling
Inputs and Outputs-Voltages
Traction
Traction Voltages Inputs and Outputs

Battery Voltage: the (120)


represents the pin location on
the controller and wiring
schematic.

Switched Battery Voltage is


the voltage from the key
switch.

Sensor Supply Voltage 1B2 is


the 5v accelerator pot voltage.

:49 and :32 are the


accelerator pot actual and
reference voltages. As the
pedal is depressed, one will
rise the other will fall. They
will always equal 5v + or - .5v

Safety Relay is the voltage


supplied internally to the relay
in the LTC.

10
Linde Material Handling
Inputs and Outputs-Currents
Traction
Traction Currents Inputs and outputs

Release Valve (1Y4) displays


milli amp reading as
directional pedal is depressed.

Pump Forward (1Y2) will read


0 with no pedal activated. As
you select a direction fwd/rev ,
the milli amp reading will
Coil Values
increase. Start of wheel
rotation will be 450 milli amp
going to a maximum of 1150
Old Square Solenoids
which equals full travel speed.
1Y4=6 ohm 1Y2=6 ohm 1Y3=6 ohm
Bypass Valve of Fan will
always start at 1600 with a
New Round Solenoids cold engine. As the engine
temperature rises the milli
1Y4=4.5 ohm 1Y2=6 ohm 1Y3=6 ohm amps will drop. As the milli
amps drop the fan speed will
increase. To view the full
operation go to Inputs and
Outputs , Traction and Temp.

11
Linde Material Handling
Inputs and Outputs-Valve Currents
Traction
Traction Inputs and Outputs Valve Currents

For LP trucks only :


Solenoid throttle valve ranges
from 420 Ma to 890 Ma based
upon the input to the controller
from the accelerator pot. With
the truck idling the throttle
valve will be moving slightly
back and forth and the ma
reading will be fluctuating , but
will always be around 420 ma.
The maximum ma reading for
the throttle valve is determined
by the position of the
LPG Valve accelerator potentiometer and
will generally be around 890
12.5 ohms ma.

The LPG cut off valve is now


controlled by the Impco
controller, unless you have
an early version 39x
machine. Either way, the ma
reading is approx 690 ma.

12
Linde Material Handling
Inputs and Outputs-Pedal Position Sensor
Traction
Traction Inputs and Outputs Pedal Position Sensor

The pedal position sensor or


accelerator potentiometer as
commonly known can be viewed
as values in this screen. Follow
the procedures given to
determine if your accelerator pot
is working within its range.

If final stop UPot1A is out of


range, the value can be altered
by adjusting the stop screws on
the floor plate.

13
Linde Material Handling
Inputs and Outputs-Engine Data
Traction
Traction Inputs and Outputs Engine Data

Engine Data. The measured


engine speed is the Linde
speed sensor 1B1 located at the
flywheel housing. The air gap is
0.5 +/-0.3mm and is the actual
engine speed.

Engine speed to ECU is the


speed recorded from the VW
engine speed sensor. The
sensor is located by the engine
oil filter housing and is listed as
0B2.

The actual and Engine speed to


ECU must be in range of each
other.
On an LP truck, you will only see the
engine speed for traction being
displayed. This is because there is no
can connection between the LTC and
Impco controller. On a diesel truck, you
will read 3 rpm readings here.

14
Linde Material Handling
Inputs and Outputs-Temperature
Traction
Traction Inputs and Outputs Temperature

The temperature screen allows


you to monitor coolant and
hydraulic oil temperature. We
also display the m/a reading for
the fan by-pass valve. As the
coolant and hydraulic oil
temperature increases, the milli
amps for the fan will decrease.
As the milli amps decrease the
fan speed will increase.

Note :

Not all fans will respond in


1Y5 Coil Value exactly the same way. If you
have a decrease in milli amps
5 ohms and the fan does not turn, but
the truck does not over-heat,
we will allow the fan to
operate this way. As long as
the fan does turn on and
operate we do not have a
problem.

15
Linde Material Handling
Inputs and Outputs-Current Codes
Working Hydraulics
Working Hydraulics Current Codes Inputs and Outputs

Inputs and Outputs / Working


Hydraulics current codes. The
fault codes and a brief
description of the code will
appear here. The most current
code will appear at the top and
will show with operating hours.

16
Linde Material Handling
Inputs and Outputs-Digital Inputs
Working Hydraulics
Working Hydraulics Digital Inputs Inputs and Outputs

In digital inputs we can see the


activation of various switches. 0
being inactive, 1 active and 2
not valid.

Displayed are seat switch


operation , limit position sensor
and switches 2S4. Limit position
and 2S4 are for 5th function
hydraulics. Numbers 9,64,84
and 99 indicate the location on
the N1 plug connector.

26,11, and 100 are optional


inputs.

17
Linde Material Handling
Inputs and Outputs-Outputs
Working Hydraulics
Working Hydraulics Outputs Inputs and Outputs

In the outputs section you can


view the release valve and
safety relay. If the component
has been activated successfully
you will see the zero change to a
1.

This is an output from the


controller after a hydraulic
function has been requested.

With the machine at idle, 2Y9


and Safety Relay will = 0. When
a hydraulic function is requested
, both will switch from a zero to
1. When the hydraulic function is
no longer required, both will drop
to zero. There is a delay in the
Safety Relay returning to zero
which is normal.

18
Linde Material Handling
Inputs and Outputs-Analog Values
Working Hydraulics
Working Hydraulics Analog Values Inputs and Outputs

Analog values. In this screen


we can see battery voltage ,
the 5v supply to the joysticks
and safety relay voltage once a
function has been requested.
Safety relay voltage will read
battery voltage.

Engine speed nominal and


engine speed actual can also
be compared.

Engine speed nominal will only


be seen when a hydraulic
function has been requested.

19
Linde Material Handling
Inputs and Outputs-Lift + Lower
Working Hydraulics
Working Hydraulics Inputs and Outputs Lift + Lower

Lift and Lower allows the


percentage values of our
calibrated joysticks to be seen.
The operating range is normally
between 0 and 100. A 6%
deviation is allowed. After 6%
has been exceeded, a fault
code will activate indicating a
joystick failure.

The solenoids for lift and tilt are


proportional and operate
between 0 and 1550 milli amps.

NOTE. In order to achieve


1550 ma, the hydraulic speed
function must be set on 100.
In order to check this, go to
Error Codes and Parameters,
Working Hydraulics , Lift , Tilt
and Aux Hydraulic speeds.

2Y1-2Y2-2Y3-2Y4 = 4.7 ohms at 20 Celsius and 7.50 ohms at 170 degree Celsius 20
Linde Material Handling
Inputs and Outputs-Aux Hydr 1-3
Working Hydraulics
Working Hydraulics Inputs And Outputs Aux Hydraulics 1-3

Auxiliary hydraulics 1-3 allows


the calibrated values of the
auxiliary joysticks to be seen.
The operating range of the
joysticks is 0-100% with a 6%
deviation allowed. If the joystick
value exceeds the limit a fault
code will set.

The solenoids are proportional


and operate between 0 and
1550 ma.

NOTE. In order to achieve


1550 ma, the hydraulic speed
function must be set on 100.
In order to check this, go to
Error Codes and Parameters,
Working Hydraulics , Lift , Tilt
and Aux Hydraulic speeds.

2Y5-2Y6-2Y7-2Y8 = 4.7 ohms at 20 Celsius and 7.5 ohms at 170 degree Celsius
21
Linde Material Handling
Inputs and Outputs-Status Aux 3
Working Hydraulics
Working Hydraulics Inputs and Outputs Status Aux. 3

Status aux 3 is for 5th function


hydraulics only.

22
Linde Material Handling
Inputs and Outputs-Cal Joystick Values
Working Hydraulics
Working Hydraulics Inputs and Outputs Calibrated Joystick Values

Calibrated joystick values are


displayed here.

Lift/lower 0.4 as an example is


the percentage of the calibrated
value to the neutral position of
the joystick.

All the values shown on the left


fall within the 6% deviation
allowed.

Note. If you have problems


trying to calibrate joysticks,
check here to see if the
calibrated values have
exceeded 6%.

23
Linde Material Handling
Inputs and Outputs-Tilt Angle
Working Hydraulics
Working Hydraulics Inputs and Outputs Tilt Angle

Tilt angle displays the


calibrated tilt values. Front and
rear end positions is the full
working stroke of the tilt
cylinder.

The 2 white boxes on the left


indicate the tilt percentage as
the cylinder is being operated.
;30 is the actual and ;103 is the
reference. When the values
move out of range of the front
and rear end positions a fault
code will be set.

24
Linde Material Handling
Inputs and Outputs-Current Codes
Display
Current Codes Display Inputs and Outputs

Current codes will be displayed


here.

25
Linde Material Handling
Inputs and Outputs-Digital Inputs
Display
Digital Inputs Display Inputs and Outputs

Digital inputs – display is where


inputs to the display can be
monitored.

For example, Oil pressure


switch, with the key on, engine
not running, a 1 is displayed.
When the engine is started the 1
changes to a zero.

26
Linde Material Handling
Inputs and Outputs- Analog Values
Display
Display Inputs and Outputs Analog Values

Analog values shows alternator


and KL15 voltage. KL15 is key
switch voltage.

27
Linde Material Handling
Inputs and Outputs- Current Codes
LOC
Current Codes LOC Inputs and Outputs

Current codes LOC. Fault


Codes for the LOC ( Linde oil
control) will be displayed here.

Note…not currently available


in the USA.

28
Linde Material Handling
Inputs and Outputs- P-Data
LOC
P-Data LOC Inputs and Outputs

P-Data tells us our current oil


level in mm and oil temperature.

Note…not currently available


in the USA.

29
Linde Material Handling
Error Codes and Parameters-System
Traction
System Traction Error Codes and Parameters

Information regarding the truck


can be seen in the general /
system.

Note. the truck serial number


will only be displayed if the
truck controller is original. If the
controller has been changed a
series of numbers and letters
will appear of no specific value.

30
Linde Material Handling
Error Codes and Parameters-Trouble
Codes Since Last Service-Traction
Trouble Codes Traction Error Codes and Parameters

This is where the most recent


error code will be shown.

On the left hand side error


code 235 is shown as an
example. It is important to note
that code 235 is in traction,
therefore the code would be
T235. The T has to be placed
in front of the code so we do
not confuse a traction code
with a hydraulic code of the
same value.

You also have the ability to


delete error codes in this
screen.

31
Linde Material Handling
Error Codes and Parameters-Trouble
Code Memory-Traction
Error Codes Parameters Traction Trouble Code Memory

Trouble code memory is where


all fault codes will be stored for
the appropriate section.

Deleting the error codes here


will delete all codes for traction.

32
Linde Material Handling
Error Codes and Parameters-Traction
Behavior-Traction
Traction Error Codes and Parameters Traction Behavior

Traction behavior is where we


can customize the driving
behavior of the machine.

To slow the machine down, you


alter Pump angle %. You
reduce the pump angle, you
reduce the truck speed. You
can also lower engine rpm in
conjunction with pump angle to
obtain the driving behavior you
are looking for. There are no
set values.

Note: reduce pump angle


Max engine speed 1600-2700 before reducing rpm.

Max pump angle 24-100 Deceleration is set between


100 and 120. The higher the
Deceleration 100-120
number the greater the braking
Backward speed 20-100 force. The truck cannot be set
lower than 100.

Backward speed adjustment is


controlling the driving speed in
reverse direction.

33
Linde Material Handling
Error Codes and Parameters-Speed
Reduction Switch-Traction
Traction Error Codes and Parameters Speed Reduction Switch

This screen is for an option


only. Travel speed reduction
should not be carried out in this
screen. An error code of T226
will be displayed if these
settings are altered without
speed reduction being installed
on the machine.

34
Linde Material Handling
Error Codes and Parameters-Power
Increase-Traction
Traction Error Codes and Parameters Power Increase

When the machine is used for


waste paper applications, or
pushing into sand/fertilizers etc
the engine will cut off due to the
low flywheel mass.
When overrun mode (function)
is set to a value 1and the
engine load reaches a
predetermined point , the
traction is switched off in order
to gain lift power. A setting of 2
will cut both traction and lift to
prevent stalling.
Speed offset allows you to set a
higher engine speed while
driving in order to give you a
higher residual when driving
Function = 0 or 2
into heaps. This setting is trial
Offset rpm = 0-500 and error.
Switch for power increase is an
Power Increase = 0 or 1 option for customers who
seldom drive into heaps. This
switch would be fitted on the
armrest.

35
Linde Material Handling
Error Codes and Parameters-Light Signals
Traction
Traction Error Codes and Parameters Light Signals

Light Signals is where we set


up the signals according to
speed or direction. We can
activate back up alarms and
lights per direction.

Note…Truck speed threshold


must be zero to activate back
up alarm.

Light = 0-3

Light Signal = 0-1

Truck Speed Threshold = 0-25

Light Signal Backward = 0-1

36
Linde Material Handling
Error Codes and Parameters-Engine Cut Off
Traction
Traction Error Codes and Parameters Engine Cut Off

Engine cut off is an optional


extra. A wiring harness is
required before this function
can be activated.

Once activated, you can


programme the truck to turn
itself off after the seat is left
unoccupied for a period of
time.

37
Linde Material Handling
Error Codes and Parameters-LPG
Traction
Traction Error Codes and Parameters LPG

When you change the LTC


controller on a 39x LPG
machine, all controllers come
set up for diesel engine.

On the earlier trucks, the LPG


shutoff valve was controlled by
the LTC Controller. So this
function had to be activated in
order for the truck to run.

The latest version of 39x has the


LPG solenoid driven from the
Impco Engine controller so this
function is not required. The
new controller and turn on
function is used with the E-
Controller from Impco.

38
Linde Material Handling
Error Codes and Parameters-Door Switch
Traction
Traction Error Codes and Parameters Door Switch

For trucks with cabs a door switch


is incorporated into the latching of
the door. You can activate this
function in this screen.

39
Linde Material Handling
Error Codes and Parameters-Speed
Acquisition-Traction
Traction Error Codes and Parameters Speed Acquisition

For the speed acquisition , the


following is important. It only
applies to 392/393 trucks.

Up to serial number
H2X393S02008 will be 135
teeth. Anything after this serial
number will be 132 teeth. It is
important that this is carried out
so correct engine speed can be
recorded. If set incorrectly the
engine will still run but run poor.

On a 392 machine, the serial


number break is anything up to
H2X392S01562 uses the 132
tooth setting.

40
Linde Material Handling
Error Codes and Parameters-Factory
Settings-Traction
Traction Error Codes and Parameters Factory Settings

Factory re-set does exactly what


it says. If you alter settings and
need to go back to the original
specs, you can select factory
reset and all functions will return
to standard.

Note: On machines where the


LP fuel solenoid is controlled
by the traction controller, be
sure to turn the LPG function
back on. The controller will re-
set to a diesel as standard
setting after clicking factory
re-set.

Before selecting factory


reset, you must ensure you
record any stored values that
are customer specific. So
once you have selected reset
you can go back and adjust
the parameters to suit the
customers requirements.

41
Linde Material Handling
Error Codes and Parameters-Trouble codes-
Working Hydraulics
Trouble Codes Working Hydraulics Error Codes and Parameters

Error Codes and parameters is


where we can view and delete
fault codes for the working
hydraulics.

42
Linde Material Handling
Error Codes and Parameters-Trouble Code
Memory-Working Hydraulics
Working Hydraulics Error Codes Parameters Trouble Codes Memory

Trouble codes are stored in the


memory. To delete the codes
simply click once on the start
button. All working hydraulic
codes will then be deleted.

43
Linde Material Handling
Error Codes and Parameters-Lift and Tilt
Speed-Working Hydraulics
Error Codes and Parameters Working Hydraulics Lift and Tilt Speed

Lift and Tilt speed is adjusted


here. It is an immediate
adjustment.

By setting the lift or tilt to 100


you will achieve maximum lift
speed. To reduce the speed ,
lower the number.

The settings range from 40-100.

Note. when performing


troubleshooting, these
settings must be restored to
100 to ensure we read the
correct information.
Especially when reading milli
amps to the valve coils.

44
Linde Material Handling
Error Codes and Parameters-Auxiliary
Hydraulic Speed-Working Hydraulics
Error Codes and Parameters Working Hydraulics Aux. Hydraulics Speed

Working hydraulics speed


adjustment. A new controller will
have the parameters set at 50.
By using the less than or greater
than arrows we can either slow
the hydraulic function down or
increase its speed. By changing
the amount of auxiliary
hydraulics from a 0 to a 1 we
can add additional hydraulic
flow.

The settings are adjustable


between 0 and 100.

Note. when performing


troubleshooting, these
settings must be restored to
100 to ensure we read the
correct information.
Especially when reading milli
amps to the valve coils.

45
Linde Material Handling
Error Codes and Parameters-Auxiliary
Hydraulics 2/3-Working Hydraulics
Error Codes and Parameters Working Hydraulics Aux. Hydraulics 2/3

For 5th function hydraulics only.


Monitoring status is watching
the movement of the proximity
switches down at the control
valve when 5th function is
installed.

Switch controlled 3rd Aux


Hydraulics is the activation of
the 5th function.

46
Linde Material Handling
Error Codes and Parameters-Mast Position
Working Hydraulics
Error Codes and Parameters Working Hydraulics Mast Position

Mast Position is an option. The


switch is fitted by the joysticks
on the armrest. It is a tilt
memory function. Operation of
this option is explained in the
operators book.

47
Linde Material Handling
Error Codes and Parameters-Fork Height
Limit-Working Hydraulics
Error Codes and Parameters Working Hydraulics Fork Height Limit

Fork height limit is an option


and does not apply to all
machines.

48
Linde Material Handling
Error Codes and Parameters-Factory
Setting-Working Hydraulics
Error Codes Parameters Working Hydraulics Factory Setting

In factory re-set we can re-set


the original truck parameters
with the re-set button. Click the
start to re-set all hydraulic
parameters.

Before selecting factory


reset, you must ensure you
record any stored values
that are customer specific.
So once you have selected
reset you can go back and
adjust the parameters to
suit the customers
requirements.

49
Linde Material Handling
Error Codes and Parameters-Trouble Code
Memory-Display
Trouble Coders memory Error Codes and Parameters Display

Trouble code memory display.


This is where we can see
trouble codes that relate to
display issues. We can also
delete the codes in this screen.

50
Linde Material Handling
Error Codes and Parameters-Operating
Data-Display
Error Codes and Parameters Operating Data Display

Operating data will be displayed


here. Any issues arising from
display errors will be shown
here.

51
Linde Material Handling
Error Codes and Parameters-Parameters
Display
Error Codes and Parameters Display Parameters

Display parameters allows us to


programme the display for the
correct model of truck.

Selection of the fuel gauge is


explained in the paragraph of
the Pathfinder software. Most
39x machines are either diesel
or lpg with pressure switch.

Time adjustments need to be


carried out when a pm service
has been carried out or when a
new controller has been fitted.

An example of time till next


service is as follows. Operating
hours is 0.4. A 50 hour service
is required. Time to next service
is entered as 50. This will count
down, when it reaches zero, the
wrench will be displayed on the
display unit.

Any changes made here have


to be saved by pushing enter on
your laptop or F5 in Pathfinder.

52
Linde Material Handling
Error Codes and Parameters-UPA Input
Display
Error Codes and Parameters Display UPA Inputs

This is an optional function to


assign spare lights in the
display unit a function.

An example of a UPA Input


would be, the installation of a
seat belt. We can activate a
light on the display and sound a
buzzer if the seat belt is not
fastened.

53
Linde Material Handling
Error Codes and Parameters-System
LOC
System Error Codes and Parameters LOC

Linde Oil Control system


information screen.

Note. not currently available


in the USA.

54
Linde Material Handling
Error Codes and Parameters-Trouble Codes
Since Last Service-LOC
Trouble Codes Since Error Codes and Parameters LOC
last Service

LOC trouble codes since last


service.

Note. not currently available


in the USA.

55
Linde Material Handling
Error Codes and Parameters-Trouble Code
Memory-LOC
Error Codes and Parameters LOC Trouble Codes Memory

LOC trouble code memory.


Fault codes will be displayed
here.

Note. not currently available


in the USA.

56
Linde Material Handling
Error Codes and Parameters-Parameter
LOC
Error Codes and Parameters LOC Parameters

LOC Parameters.

Note. not currently available


in the USA.

57
Linde Material Handling
Additional Settings For Specific Truck
Type

2005
2002
2007

BR392 / H20-25
BR391 / H14-20 BR393 / H30-35 BR394 / H40-50

58
Linde Material Handling
391 Error Codes and Parameters
Traction Properties 2-Traction
Traction Error Codes Parameters Traction Properties

Traction properties allows you


to smooth out the creep control
of the machine. For a smooth
operation at low speed select
1. This is useful when handling
delicate loads.

59
Linde Material Handling
391 Inputs and Outputs - Brake
Potentiometer - Traction
Traction Inputs and Outputs Brake Potentiometer

The brake potentiometer is


installed on 39x machines with
coast control. These machines
are normally fitted with a red
brake pedal. The potentiometer
requires values similar to the
traction potentiometer and
requires calibrating.

60
Linde Material Handling
391-3rd Aux Hyd via Joysticks
Working Hydraulics
Working Hydraulics Inputs and Outputs 3rd Aux. Hydraulics

For 5th function hydraulics only.

61
Linde Material Handling
391- Inputs and Outputs-P-Dat
LOC
P- Data Inputs and Outputs LOC

Not available in the USA.

62
Linde Material Handling
392-Error Codes and Parameters
Buchholz Valve-Working Hydraulics
Error Codes and Parameters Working Hydraulics Buchholz Valve

Early 392 machines had a


Buchholz hydraulic control valve
instead of the current Linde
control valve. The difference
between the two is clearly seen
in Lindos. If you have to fit a
new controller, you must
determine, is it a Buchholz or
Linde control valve. If it is a
Buchholz you must set the value
in the window to let the
controller know which valve it
has.

The coil values are different


between the two which is why
we have to do this.

63
Linde Material Handling
392-Inputs and Outputs Brake
Potentiometer-Traction
Traction Inputs and Outputs Brake Potentiometer

392 machines can be fitted with


an ( automatic ) function which
will let the truck operate like a
torque converter machine. This
type of truck uses a brake
potentiometer which is not
found on standard machines.
This screen allows us to
monitor the values of the brake
potentiometer.

64
Linde Material Handling
394-Error Codes and Parameters
Overrun Mode-Traction
Error Codes Parameters Traction Overrun Mode

When the machine is used for


waste paper applications, or
pushing into sand/fertilizers etc
the engine will cut off due to
the low flywheel mass.

When overrun mode (function)


is set to a value 1and the
engine load reaches a
predetermined point , the
traction is switched off in order
to gain lift power. A setting of 2
will cut both traction and lift to
prevent stalling.

Speed offset allows you to set


a higher engine speed while
Function = 0 or 2 driving in order to give you a
higher residual when driving
Offset rpm = 0-500 into heaps. This setting is trial
Power Increase = 0 or 1 and error.

Switch for power increase is an


option for customers who
seldom drive into heaps. This
switch would be fitted on the
armrest.

65
Linde Material Handling
394-Inputs and Outputs-Retarder
Traction
Traction Inputs and Outputs Retarder

Only found on 394 H45-H50


models. The brake retarder
valve is activated when over
speed is detected by the
controller. The retarder valve
will operate between 0-
900m/amps and will reduce the
over speed condition by
dumping oil to tank.

IY1 Retarder Valve

5.2 ohm

66
Linde Material Handling
394-Inputs and Outputs-Currents
Traction
Release Valve (1Y4) displays
milli amp reading as
directional pedal is
depressed.
Pump Forward (1Y2) will read
0 with no pedal activated. As
you select a direction fwd/rev
, the milli amp reading will
increase. Start of wheel
rotation will be 450 milli amp
going to a maximum of 1150
which equals full travel
speed.
Bypass Valve of Fan will
Cold Start Valve always start at 1600 with a
8 ohms cold engine. As the engine
temperature rises the milli
amps will drop. As the milli
amps drop the fan speed will
increase. To view the full
operation go to Inputs and
Outputs , Traction and Temp.
Cold start valve 1Y11 is
activated if temperature
drops below 5 degree
Celsius to aid cold starting of
the engine. It does this by
dumping hydraulic pressure
to tank during cranking.
67
Linde Material Handling
394-Inputs and Outputs-State of Aux
Hyd 3-Working Hydraulics
Working Hydraulics Inputs and Outputs State of Aux. 3 hyd.

For 5th function hydraulics


only.

68
Linde Material Handling

Offline Diagnostics

Guided Diagnosis Start

Offline diagnostics is where we


can get a full description of a
fault code being shown on the
display unit. It does not matter
if you are in the LTC or VW
engine controller, the
procedure is the same.

Click on offline diagnosis, then


click the start button at the
bottom right hand corner.

See next page.

69
Linde Material Handling

Offline Diagnostics
Traction

Once you are in this screen


you can select which control is
giving you the problem. For
instance, if a fault code (T231)
was being displayed , click on
traction. Once you click
traction, a list of codes will
appear.

By pressing the re-set button,


you will be directed back to the
first page of Pathfinder.

T= Traction Fault Code

L= Hydraulic Fault Code

D= Display Fault Code

LOC and LPF are not yet


available in the USA.

See Next Page

70
Linde Material Handling

Offline Diagnostics
Fault Codes

Use the scroll bar on the right


hand side and locate your error
code. Once you find our
example of (T231) , click on the
number. You will now bring up
the fault code description.

See next page.

71
Linde Material Handling

Offline Diagnostics

Fault Code T231

Fault code (T231) Traction.

What does it mean?

Read the code, what it is telling


us is the controller has detected
that the voltages supplied by
the master and monitoring
potentiometers has an incorrect
value. The potentiometer works
off 5v. In a neutral condition we
should read 2.5v and 2.5v. The
controller is telling us that this is
not happening so it throws the
fault code (T231). 49 and 32
are the controller plug
connections, this is where the
voltages are being read. Go to
Inputs and Outputs traction,
click voltages and you will see
49 and 32. Here we can verify
what voltage we have at the
accelerator potentiometer.

The key to tracing faults on a


39x machine is reading and
understanding the fault code.

72
Linde Material Handling

Pathfinder

From Linde Product Support 2008