BMF Motors The >short< motor for high-pressure high-speed applications 3. General technical data ‘litte. 3.1 Weight see dimensional tables Mineral oil type HL or HLP due to DIN 51524, other hydraulic fluids on application 3.2 Hydraulic fluid 3.2.1 Fluid temperature range ~ 20°... + 90° [C} 3.2.2 Operating viscosity range 10 ... 80 [mm?is] 3.2.3 Optimum operating viscosity range 15... 20 (mm*is} 3.2.4 Peak viscosity (transient condition during start-up) 1000 [rmm?/s} Recommendations: 40° [C] 22 [mm*/s] at 40° [C] 70° [C] 68 [mm*s] at 40° [C] 90° [C] 100 [mm/s] at 40° [C] Aside from the minimum requirements to DIN 51 524, any brand hydraulic fluid used must also meet all the requirements inherent in a high pressure hydraulic system. This applies in particular to so-called HLPD (detergent) ails. Linde recommends that only those hydraulic fluids be used, the suitability of which for high-pressure hydraulic systems can be guaranteed by the manu- facturer In order to select the correct hydraulic fluid, the operating temperature in the Circuit (closed loop) must be known. The hydraulic fluid should be selected such that, in the operating tem- perature range, the operating viscosity lies in the optimum range (see 3.2.3). Not ‘As a result of the influence of pressure and speed, the leakage oil temperature is always above the circuit temperature. At no point in the system should the temperature be higher than 90° Ic) Hf the conditions indicated cannot be complied with in specific applications, please consult us. 3.3. Filtration Filtration of the hydraulic circuit is necessary Note! When employing the motors in combination with Linde's BPV vatiable displacement pumps in closed circuit systems, no ad- ditional filter is necessary as one is fitted to these pumps as standard, Recommended filtration: 10 microns (fiters with 25 - 40 microns may also be used). Linde uses and recommends 10 micron filters. These correspond to the cur- rent stale of the art and can be obtained from the usual commercial sources, at no additional expense. Moreover, the finer degree of filtration substantially increases the uselul service life of the hydraulic equipment (less wear). Torque Maj) = Mdgonst. * AP Qe 1000 Speed n= % cs (Nen} = Tea atedine sha 40 (oa) = ite esse ben nt ott Yq (n°) = Geom ospaomex Op {Linin) = Toei Nowe lem) = Opes mech = 088 asngensctaril cine) met ~ 097 (eager tiers) 4. Power take-off 5. Fluid cooling 6. Side and axial loading Lite. 3.4.1 Output torque Md const, tNenibar] | 0.557 | 0.796 | 1.194 | 1.672 | 2.229 | 2.962 | 4.14 Md max theor, Nm) 234 | 334 | sot | 702 | 936 | 1244 | 1739 at p = 420 bar 3.4.2 Output speed Q sreoreticar (Limin] | 171.5] 225 | 300 | 378 | 462 | 558 | 702 at imax (pm) | 4900 | 4500 | 4000 | 3600 | 3300 | 3000 | 2700 Poont ther W) | 64 | a6 | 119 | 142 | 172 | 219 | 267 at p = 250 bar and max Coupling Suitable coupling elements must be employed for the power take-off (please consult us it you have special application requirements or load conditions). Moment of inertia ‘Moment of inertia. {kgm*| |0.0023| 0.0038] 0.0093 0.0175) 0.0338 0.0458]0.0615 5.1 Requisite cooling capacity Determined in accordance with the overall heat balance of the hydrostatic system. 6.1 Maximum side and axial forces Fy and Fax Related to centreline, shatt end (side load application point at distance L) at continuous pressure = 250 bar and maximum speed Load L Fa Faxg Faxz oltset L [kN] {KN} tkNy] [mm] Transient loading of double these figures is permissible. If the per- missible force values indicated in the table are likely 10 be exceeded in special applications, please consult us. 1. Description 4.1. Design principles and components Our BMF ... fixed displacement motors are bent axis units which are suitable for both open and closed loop systems. It required, they can also be equipped with a purge valve for circuit and case flushing. Coupling flanges are likewise available as an optional extra. 1.2 Design features * Bent axis fixed displacement motor with a tit angle of 28° * Extremely robust rotary group with drive shaft rated for side loads ‘+ SAE high-pressure ports © Optional purge valve for circuit and case flushing + Noadditional piping required for circuit and case flushing + Particularly quiet operation + Ultra-short design * Clockwise and anti-clockwise rotation HHI ch pressure [EB 00» pressure [aaa] Casing pressure BMF ....C fixed displacement motor with circuit and case flushing ‘Genoa 1000 2. Specifications litte. 1.4. Circuit diagram LU) a” B uly BMF BMF with circuit and case flushing Key AandB = Main ports Lu) Drain ports ul) Flushing ports 1.5 Type designation | BMF| Fixed displacement motor (series B) Nominal size 35, 50, 75, 105, 140, 186, 260 With integral purge valve for circuit and case flushing = C pesnesneseseesessesseses 2.1 Pressures Maximum pressure * 500 [bar] Rated pressure ( = maximum operating pressure) 420 [bar] Continuous pressure ** 250 [bar] Permissible internal case pressure 1.5 [bar] 2.2 Displacement fom’) 34.7 502/749] 105 | 140 | 188 2609 2.3 Speed trom] Max. speed (100 % duty cycle) | 4500|4200|3700)3300| 3000] 2800| 2500 Peak speed (transien!) 4900] 4500| 4000|3600|3300|000|2700 ‘Size 195 available on application 7. Motor dimensions Aand B = Main pots 8. Appendix 8.1 Coupling flanges Drain ports, M 221.5, Fuushing ports, M 22 1.5 c BMF ... fixed displacement motor with coupling flange 8.2 Dimensions 8.2.1. Coupling flange for output shaft, Dimensions (in mm) Dimensions (in mm) ala a ately Talal ae] ee) > | sane | wee ala ]a]) 4 ].4 | Barium sae si 8 9231 SAE ange oun se | (SAE) = 30° wean press. seres | [kg] | 13 | wae] 100] esx) ~~ eee] wea] ee] ws |r| ws posp ee] ow | is 10} 05 | a7] 6xa2 | ama | | ws prs] 1 450 | 100 |eaoxar| — | 12 |se6| 69 | 190] 7» | a0 | srs |x| es | ow | 18 10] 995 | 57 | 6xez | asoxar | | ois} | ia imo | ts |easxat} — | r4fese| ea | 140] 77s | 20 | ars | arm] 1: | a 2] ius| 7 | sxe2 | assxat | iors| as] 7 | 09 soi | 125 | e40xa6} — | 18 |707| a3 | 150 | ass | 2605 | 955 | 205] a | 1: | a 12} 10 | 7 | exe2 | asoxae | 1o1s| sss fro | 25 200 ol aasxar| — | 16 |r07| 102 | 180 | 108 | 208 | 115 | a40 frre | tam a7 12] 10 | 75 | oxro2 | assxa | rors | ts | a |, 24 aio | 160 | esoeas] — | 18|r92{ 107 | 186 | 120 | 306 | ist | aso fie) ive | sr a5 | wo | oo [8x02| asoxas | 1a | is |e | 6 io {iess] — | sozasse | 22 | a1 | 101 | 200 | rae | ors | — | aoefire | sim | os eee pe eee eee | aCe cee ESC Ea 6 Linde AG, Werksgruppe Flurférderzeuge und Hydraulik P.O.Box 62, D-63736 Aschatfenburg Phone (int. + 6021) 99-0, Telex 41880118 la d, Fax (int. + 6021) 99-1579

You might also like