1. SCOPE
This document describes the performance characteristics and testing methods for Polymer
Lithium-ion batteries produced by shenzhen pkcell battery Co., Limited.
2.SPECIFICATION
No. Item Characteristics Remarks
Minimum:6270mAh Standard discharge(0.2C5A)
1 Nominal Capacity
Typical: 6600mAh after Standard charge
2 Nominal Voltage 3.7V —
3 Charging Cut-off Voltage 4.2V —
4 Discharge Cut-off Voltage 3.0V —
Constant Current 0.5C5A
5 Standard Charge Constant Voltage 4.2V Charge Time : Approx 4.0h
0.01 C5A cut-off
Maximum Constant
6 1650mA(0.25C) —
Charging Current
Maximum Continuous
8 3300mA(0.5C) —
Discharging Current
Charge 0~45℃
9 Operating Temperature —
Discharge –20~70℃
-20~45℃ for 1Month
10 Storage Temperature —
-20~35℃ for 6Months
11 Storage Voltage 3.7V —
If the materials of the product
and packaging accord with
12 Environmental request RoHS
RoHS standard,there will be
a RoHS Id on the box.
3. Dimensions
Please refer the drawing in appendix.
4. Appearance
No scratches, dirt, defect, leakage of electrolyte or gassing should be observed as a new product.
Page 2 of 7
SHENZHEN PKCELL BATTERY CO., LTD
Technical Specification Edition A/0
PKCELL Document ICR18650 6600mAh Valid Date 2014-07-30
BATTERY 3.7V Drafted by Xiao li
Number QA.S. 0221 Signed by Zhijiang Li
6. Characteristics
6.1 Electrochemical performance characteristics
No. Item Testing Method Requirements
CCCV or Constant current charge to 4.2V @1C follow
Fully Charged
1 by a constant voltage holding at 4.2V until current —
State
drops below 66±3mA.
CCCV at 4.2V (per 6.1.1) at room temp. (20±5C), rest
Rated for 1-2 hrs then discharge at a constant current of
2 ≥6270mAh
Capacity 0.2C to 3V, testing will be terminated by either 5 cycles
or any one discharge time exceeds 5 hrs
Discharge to 3V @1C, then CCCV charge to 4.2V,
Cycle Life rest for 10 min. discharge @ 1C to 3.0V and rest for
3 Cycle life ≥500
@25℃ 10 min. Continue the charge/discharge cycles until
discharge capacity lower than 70% of rated capacity.
Internal Internal impedance is measured on a 50% charged
4 —
Impedance battery at 1KHz AC at ambient temperature(20±2)℃
Capacity Fully charge cells per 6.1.1, store them at (20±2)℃ for Discharge
5
Retention 28 days, then discharge the cells to 3.0V at 0.2C. Capacity≥5280mAh
High
Fully charge cells per 6.1.1, store them at (55±2)℃ for Discharge
6 Temperature
2 hours, then discharge the cells to 4.2V at 0.2C. Capacity≥5280mAh
Characteristics
Low Fully charge cells per 6.1.1, store them at (-10±2)℃
Discharge
7 Temperature for 16~24 hours, then discharge the cells to 3.0V at
Capacity≥3960mAh
Characteristics 0.2C.
Cell Voltage
Check open circuit voltage (OCV) of cells prior to the
8 during ≥3.7V
delivery to customers
Transportation
Page 3 of 7
SHENZHEN PKCELL BATTERY CO., LTD
Technical Specification Edition A/0
PKCELL Document ICR18650 6600mAh Valid Date 2014-07-30
BATTERY 3.7V Drafted by Xiao li
Number QA.S. 0221 Signed by Zhijiang Li
6.3 Reliability
No. Item Test Method Requirements
Electrochemical
High
performance、
1 Temperature Fully charged per 6.1.1,then rest at 60±2℃ for 2 hours.
visual test not
Test
changed
No appreciable
Low
Fully charge cells per 6.1.1, rest at -20±2℃ for 2 hours. alternation
2 Temperature
Then the cells are placed at room temperature for 3 hours. electrochemically
Test
and visually
No appreciable
Fully charge cells per 6.1.1, rest at 40±2℃ with 90%~
Humidity alternation
3 95RH% for 48 hours. Then the cells are placed at room
Test electrochemically
temperature to “dry out” for 2 hours.
and visually
After standard charged, fixed the cell to vibration table and
subjected to vibration cycling that the frequency is to be No fire
Vibration
4 varied at the rate of 1Hz per minute between 10Hz an No explosion
Test
55Hz, the excursion of the vibration is 1.6mm. The cell No leakage
shall be vibrated for 30 minutes per axis of XYZ axes.
No fire
Drop The cell is to be dropped from a height of 1 meter twice
5 No explosion
Test onto concrete ground.
No leakage
After the vibration test, according to X.Y.Z each battery
No fire
average three vertical pulse peak acceleration, the setting
6 Collisions No explosion
for the 100m/s2, every minute, 40 ~ 80 collision frequency,
No leakage
pulse duration 16ms collision frequency ± 10 thousand.
No fire
Crush (Fresh, Crush between two flat plates. Applied force is
7 No explosion
Fully charged) about 13kN(1.72Mpa) for 30min.
No leakage
This test will be placed the battery electric dipole in the No explosion,
fume hood, short-circuit the anode (total resistance is not No fire
Short
8 more than 50mΩ lines), monitor temperature changes, The temperature
Circuit
when the battery is low temperature dropped to about 10 of the surface of
degrees than peak, the end of experiment. the Cells≤150℃
A 56mm diameter bar is inlayed into the bottom of a 10kg
Impact(Fresh, No fire
weight. And the weight is to be dropped from a height of
9 Fully charged) No explosion
1m onto a sample battery and then the bar will be across
No leakage
the center of the sample.
Page 4 of 7
SHENZHEN PKCELL BATTERY CO., LTD
Technical Specification Edition A/0
PKCELL Document ICR18650 6600mAh Valid Date 2014-07-30
BATTERY 3.7V Drafted by Xiao li
Number QA.S. 0221 Signed by Zhijiang Li
Thermal No fire
Batteries in hot box Temperature in 5℃±2℃/min,rising to
10 shock(Fresh, No explosion
50℃±2℃ keep 30min
Fully charged) No leakage
No obvious
Standard after the battery, Will a battery into 40℃±2℃,
deformation,
Constant Relative humidity90%~95% At constant temperature and
hands rust,
11 damp humidity box after 48h Battery will in environmental
smoke, explosion,
performance temperature 20±5℃ Aside 2h, 0.2C5A to terminate
discharge time
discharge current voltage,
≥36 min
7. Warranty
Warranty period for this product is 6 months starting from the date when the products left the door
of manufacturer.
8. Liability
The user has to operate the products according to the instructions printed on the battery label or
follow the advices described in this “Product Specification for Lithium Ion Batteries published by
shenzhen pkcell battery Co., Limited. In case the battery were overheated or even catch fire or
explosion caused by mishandling of the user side, shenzhen pkcell battery Co., Limited. will not be
liable for the lose caused by any of such mishandling. shenzhen pkcell battery Co., Limited. will
notify the users in written form if any modifications in specification, raw material, production
process control.
9. Battery Packing Label
The following warnings should be indicated on the battery pack labels.
Use a specified charger.
Do not throw the battery into fire, or heat.
Do not short-circuit the battery terminals.
Do not disassemble the battery.
Page 5 of 7
SHENZHEN PKCELL BATTERY CO., LTD
Technical Specification Edition A/0
PKCELL Document ICR18650 6600mAh Valid Date 2014-07-30
BATTERY 3.7V Drafted by Xiao li
Number QA.S. 0221 Signed by Zhijiang Li
12.Dimensions
Page 6 of 7
SHENZHEN PKCELL BATTERY CO., LTD
Technical Specification Edition A/0
PKCELL Document ICR18650 6600mAh Valid Date 2014-07-30
BATTERY 3.7V Drafted by Xiao li
Number QA.S. 0221 Signed by Zhijiang Li
……..END……..
Page 7 of 7