DESIGN DRAWING CANOPY PROPOSE DRAWING CANOPY

( CANOPY TYPE B ) ( CANOPY TYPE B - LINE D)


PROPOSE
Note-1 - The canopy cannot be connected to the existing post grid because it will clash with the joint girt
Propose Note-1 - We changed the canopy distance from 1610 to 1400 & 1310 so there is an
Note-2 - For the top canopi cannot be connected because there is no post
additional add post
Propose Note-2 - For connection to conopy we add post
DESIGN DRAWING CANOPY PROPOSE DRAWING CANOPY
( CANOPY TYPE B ) ( CANOPY TYPE B - LINE G)
PROPOSE
Note-1 - The joint bolt upper canopy clashes with gusset plate Add post Propose Note-1 - We changed the length of the gusset plate to 60mm which was welded
Note-2 - The upper canopy clashes with existing door post joint (bolt) to the add post (80mm design)
Propose Note-2 - We changed the canopy distance from 1610 to 1400 so there is an
additional add post