0> DATE: 2002-03-22

GCU-
GCU-2000 manual (Operator)

-1-
GCU-2001 Manual <Ver. 1.0> DATE: 2002-03-22

-Contents
Contents-

1. MAIN
1.1 Operation mode of Group controller ......................................................................................... 3
GCU Auto Mode ......................................................................................................... 3
1.2 CPx display Explanation ....................................................................................... 3
2. GCU CATEGORY........................................................................................................5
2.1 VER ................................................................................................................... 5
2.2 VIEW................................................................................................................. 5
2.3 OPT ................................................................................................................... 6
2.4 SETUP ............................................................................................................... 7
2.4.1 Group Parameter0 ..................................................................................................................... 7
2.4.2 Group Parameter2(Over GCU2.3) ............................................................................................ 9
2.4.3 Basic Floor .............................................................................................................................. 11
2.4.4 Set Time .................................................................................................................................. 11
2.5 PROG ............................................................................................................11

-2-
GCU-2001 Manual <Ver. 1.0> DATE: 2002-03-22

M
O
DP
::::::
G
C
U----M
A
U
T
O
CC
1P

1
0

A
u
t
ot
2P

3
1

A
u
om
CC
3P

C
o
Er
4I

P
a
k
T
M
A
0
4
:
5
0
:
0
0
G
C
U
a
u
t
o
o
p
e
r
a
t
i
o
n

1. Main

1.1 Mode Operation mode of Group controllers

- GCU Auto: Auto Mode

- Generator CTR: Mode under operation of generator


- Fire Control: Fire control operation mode
- Parking: Parking mode (PKS)
- Seismic Very Low: Seismic control operation mode (SVL)
- Seismic Low: Seismic control operation mode (SL)
- Seismic High: Seismic control operation mode (SH)
- Office Ready: Office-going hour operation mode (Note)
- Lunchtime: Lunchtime operation mode (Note)
- Office Close: Office-closing operation mode (Note)
- Power Saving: Saving of electricity operation mode
- Auto Parking: Auto parking operation mode

1.2 CPx display Explanation

CP1: σ 20 Autos
Status
Floor Display
Running direction
- Display of Status
. Auto: Auto mode
. Come: Communication error

-3-
GCU-2001 Manual <Ver. 1.0> DATE: 2002-03-22

. Park: Parking
. VIP: VIP operation
. “ “ : Fault or impossible auto operation status
※ Depends on OPP-2000 Version, some of letters can’ t be displayed.

-4-
GCU-2001 Manual <Ver. 1.0> DATE: 2002-03-22

2. GCU Category

- GCU CATEGORY -

VER VIEW OPT

SETUP PROG KEEP

2.1 VER

Indicate Group and PSD version number in the each MCB board.

Version:
1. GCU-2000 : 2.30
2. MCU1 : 3.00
3. MCU2 : 3.00
4. MCU3 : 3.00
5. MCU4 : 3.00

Select NO:
1. Hall Call 4
2. ABHall Call 4
3. Defect HIB(A) B/T4
4. Defect HIB(B) B/T4

2.2 VIEW

1. Hall Call: Indication of condition for car/hall call registration.

2. AB Hall Call: Indication of condition for Disabled hall call registration.


3. Defect HIB (A) B/T: HIB (A) Button Jam.
4. Defect HIB (B) B/T: HIB (B) Button Jam.

-5-
GCU-2001 Manual <Ver. 1.0> DATE: 2002-03-22

Select Option:
1. Office Ready [Off]
2. Lunchtime [Off]
3. Office Close [Off]
4. Power Saving [Off]
5. Auto Parking [Off]
6. BasicFL Swap [Off]
7. Dispersion [Off]
8. Option 8 [Off]
9. Buzzer On/Off [Off]

2.3 OPT

1. Office Ready: option of office-going hour operation (Note1.)

2. Lunchtime: option of lunchtime operation (Note1.)


3. Office Close: option of close of office hour (Note1.)
4. Power Saving: option of power saving.
5. Auto Parking: option of Auto parking operation.
6. Basic FL Swap: option of reversed operation to basic floor.
7. Dispersion: option of dispersed standing operation.
8. Option8: Option of Group VIP operation (note1.)

9. Buzzer On/Off: Option of OPP Buzzer On/Off.

※Note1.It can be supported over GCU2.3 Version.


Depends on OPP-2000 Version, it can be displayed “ Group VIP” .

-6-
GCU-2001 Manual <Ver. 1.0> DATE: 2002-03-22

SetUp Parameter:
1. Group Parameter0 4
2. Group Parameter1 4
2. Group Parameter2 4
3. Basic Floor 4
4. Set Time 4

2.4 SETUP

2.4.1 Group Parameter0

It is a item of parameter setting for Group control.

GCU Parameter 0:
1. GCU Mode 1
2. OpOverTime 0 sec
3. DisperTime 10 min
4. GCU Prm0 3 Car
5. GCU Prm1 1 Car
6. GCU Prm2 0

1. GCU Mode
It is an item to set up the Control system of Group Controller.
2. OpOverTime
It is time to detect the Door open for long time. The unit is second.
The range of setting value is 1 ~ 250sec, and ignore other value.
3. DisperTime
It is time to detect the dispersion waiting operation. The unit is minutes.
The range of setting value is 1 ~ 30min, and ignore other value.
4. GCU Prm0
Setting menu of parking lifts when it is a power saving operation
Range of setting value is 1 ~ 3car and ignore other value.
5. GCU Prm1
6. Setting menu of parking lifts when it is auto-parking operation.
Range of setting value is 1 ~ 4car and ignore other values.
7. GCU Prm2 (over GCU1.7)

-7-
GCU-2001 Manual <Ver. 1.0> DATE: 2002-03-22

In the case of specification of handicap external call, set up the handicap lift.
Range of setting value is 0 ~ 4 and ignore other values.
In these case of setting value is 0 and ignore the handicap external call.
※ Revised item over GCU2.3 Version
“In the case of OPT  8. Option 8 [On] “Option is “ON”, it is used as a handicap lift, not
VIP lift.

-8-
GCU-2001 Manual <Ver. 1.0> DATE: 2002-03-22

2.4.2 Group Parameter1 (Over GCU1.7)


It is parameter to control the different starting floor as a group.
It is possible to input the starting floor 0 ~ 4, 0 means the bottom floor. (Default 0)

Group Parameter 1:
1. GCU Prm10 0
2. GCU Prm11 1
3. GCU Prm12 2
4. GCU Prm13 3

[Explanation]
1. GCU Prm10 0 → The value of starting floor L1
2. GCU Prm11 1 → The value of starting floor L2
3. GCU Prm12 2 → The value of starting floor L3
4. GCU Prm13 3 → The value of starting floor L4

2.4.2 Group Parameter2 (Over


(Over GCU2.3)
GCU2.3)

Group Parameter 2:
1. GCU Prm20 4
2. GCU Prm21 2
3. GCU Prm22 3
4. GCU Prm23 1
5. GCU Prm24 3
6. GCU Prm25 0
7. GCU Prm26 0
8. GCU Prm27 255

1. GCU Prm20 4 → The return sequence of L1 to main floor by generator


2. GCU Prm21 2 → The return sequence of L2 to main floor by generator
3. GCU Prm22 3 → The return sequence of L3 to main floor by generator
4. GCU Prm23 1 → The return sequence of L4 to main floor by generator
5. GCU Prm24 3 → The auto operation Lift no. Setting after returning.
6. GCU Prm25 3 → It is a time code for Peak Mode operation.
7. GCU Prm26 3 → It is call table code value for Peak Mode operation.
8. GCU Prm27 3 → It is call setting code for Peak Mode operation.

-9-
GCU-2001 Manual <Ver. 1.0> DATE: 2002-03-22

- GCU Prm25 ~ 27: It is function to prohibit the car or hall calls for Peak Mode during
setting hour.
- GCU Prm20 ~ 23
. Input value is 1 ~ 4 and ignore other value.
- GCU Prm24
Set up the auto operation lift after return to main floor.
Setting value is 0 ~ 15, and ignore other value.
Setting
CP4 CP3 CP2 CP1 Explanation
Value

0 0 0 0 0
0 0 0 1 1
0 0 1 0 2
0 0 1 1 3
0 1 0 0 4
0 1 0 1 5
0 1 1 0 6
0 1 1 1 7 If the lift is 1, it is possible to
operate as an auto after
1 0 0 0 8 returning to main floor.
1 0 0 1 9
1 0 1 0 10
1 0 1 1 11
1 1 0 0 12
1 1 0 1 13
1 1 1 0 14
1 1 1 1 15
GCU Prm25
It is time code value for Peak Mode operation.
0: attendance hour 1: before lunch hour 2: after lunch hour 3: leaving hour

GCU Prm26
It is call table code for Peak Mode operation.
0: 1~ 8FL Car 5: 1~ 8FL Hall Up 10: 1~ 8FL Hall Down
1: 9~16FL Car 6: 9~16FL Hall Up 11: 9~16FL Hall Down
2: 17~24FL Car 7: 17~24FL Hall Up 12: 17~24FL Hall Down
3: 25~32FL Car 8: 25~32FL Hall Up 13: 25~32FL Hall Down
4: 33~40FL Car 9: 33~40FL Hall Up 14: 33~40FL Hall Down

-10-
GCU-2001 Manual <Ver. 1.0> DATE: 2002-03-22

- GCU Prm27
It is call setting value for Peak Mode operation.

Non operation code = A Remark


A*8+7 A*8+6 A*8+5 A*8+4 A*8+3 A*8+2 A*8+1 A*8+0 FL calculation
B7 B6 B5 B4 B3 B2 B1 B0 BIT NO.
Setting value
(B7*128)+(B6*64)+(B5*32)+(B4*16)+(B3*4)+(B2*2)+(B1*1)
Calculation

* Ex)
Attendance hour and prohibit the Hall Down call of 2,3FL out of 1 ~ 8 FL.
+ Time code: 0
+ Call Table code: 10
+ Call setting code: 249
B7 B6 B5 B4 B3 B2 B1 B0 FL calculation
1 1 1 1 1 0 0 1 1:Validity, 0: Invalidity

(1*128)+(1*64)+(1*32)+(1*16)+(0*4)+(0*2)+(1*1) 249

2.4.3 Basic Floor


Main FL setting value at Group Control.

2.4.4 Set Time


Setting value for year, month and time.

SetUp Program Time :


1. Office Ready 4
2. Lunchtime 4
3. Office Close 4
4. Power Saving 4
5. Auto Parking 4
6. BasicFL Swap 4

2.5 PROG

1. Office Ready: Setting mode for the time of office-going hour operation (Note)

2. Lunchtime: Setting mode for the time of lunchtime operation (Note)

-11-
GCU-2001 Manual <Ver. 1.0> DATE: 2002-03-22

3. Office Close: Setting mode for the time of office-closing hour operation (Note)

4. Power Saving: Setting mode for the time of power saving operation

5. Auto Parking: Setting mode for the time of Auto parking operation

6. Basic FL Swap: Setting mode for the time of reversed operation into basic floor

※ The starting/ending date is automatically setting Mon to Saturday at program.

※ Lunchtime can input only 2 times at starting/ending hour.

※ Distinguish the before/after lunch hour in the middle of lunch hour.

※ Note : It is possible to support over GCU2.3 Version.

※ In case related option is "OFF", can't enter the setting mode.