Professional Documents
Culture Documents
1. For general notes refer to drawing nos. SD-NT, SD-01, SD-02. ----- sheet of -----
2. Read this drawing in conjunction with other relevant
Structural drawings.
3. Contractor is required to verify all dimensions with Architectural
and M&E drawings prior to construction. BUILDING AND CONSTRUCTION AUTHORITY
APPROVED UNDER SECTION 5 / SECTION 5A OF THE
BUILDING CONTROL ACT (CHAPTER 29)
6-1 6-2 6-3 6-4 6-5 6-6 6-7 6-8
Project Ref No. A1716-00002-2019 ST06
6225 2350 7400 5250 1525 5550 7125
Variable Action
Description
(kN/m2)
Residential unit (except balcony) 2.0
Lift Lobby, Staircase, Corridor, Balcony 3.0
6-A
Lift motor room, all M&E rooms 7.5
RC flat roof (accessible for maintenance only) 1.5
C2DK
C3b (handed)
(handed)
BHS1a
9850
(handed)
6-B
1525
6-C
(150x750) us
DN (200)
2-LB1
UP
8850
C1b BHS1b C1a1
(handed) (handed) (handed)
6-D
ACCREDITED CHECKER
No: 1158
LEGEND
DENOTES CAST IN-SITU WALL / COLUMN
L
I ON A EN
S G
S
FE
IN
P RO
EER
CIVIL
TAN CHEE HEAN
3707
S IN
GA P O RE
SUBMISSION
P & T CONSULTANTS PTE LTD
Structural & Civil Engineers
1303, CLIFFORD CENTRE TEL: 65352011
24 RAFFLES PLACE FAX: 65345496
SINGAPORE 048621
PROJECT
BLOCK B6
2ND STOREY FRAMING PLAN
PROJECT NO DRAWING NO
SE1820 FP6-02
REVISION: