STIFFENER RIB
4 PLACES 12
78 35

STIFFENER RIB 55
R5 FILLET TO
TOP FACE EDGES 3.2

3.2

25
3.2

40

35
60
A
-

35
20

3.2
125

A TYPICAL SECTION
-
R12.5

HOLD-DOWN SLOT
NOTES
4 PLACES 1. ALL EDGES TO BE SQUARE.
2. ALL EDGES TO BE ARRISED UNLESS
SHOWN OTHERWISE.
25

3. ALL FILLETS TO BE 5mm RADIUS UNLESS


SHOWN OTHERWISE.
4. CASTING TO BE FREE OF BURRS AND PITS.
800 PCD 5. MACHINE SURFACE SYMBOL 3.2

6. MATERIAL: GREY CAST IRON (AS1830)


PLAN TENSILE STRENGTH: ISO 185/JL/225
HARDNESS: 145 - 215 (HB)
ULTIMATE DESIGN LOAD: 210 KN (AS3996)
7. TOLERANCES:
CAST DIMENSIONS
ANGLE PROFILE
MACHINED DIMENSIONS
OVERALL MAJOR
DIAMETER OF COVER +0 -0.25mm
125 125 DFT OF COATING 50um
8. ALL MACHINED SURFACES SHALL HAVE A COATING
APPROVED AS FIT FOR THE PURPOSE OF PROVIDING A
RUST PROOF, NON-STICK AND GAS/WATER PROOF
JOINT.
9. ALL NON MACHINED SURFACES TO BE BITUMINOUS
COATED IN ACCORDANCE WITH AS 3750-4.
SECTIONAL ELEVATION A 10. ALL WORK SHALL BE IN ACCORDANCE WITH CURRENT
- QUEENSLAND CODE, SPECIFICATIONS AND
FOR USE IN NON TRAFFICABLE LOCATIONS STANDARDS.
MAINTENANCE HOLE FRAME 11. COVERS AND FRAMES TO BE SUPPLIED ASSEMBLED.
12. CERTIFICATION OF COMPLIANCE TO A.S. 3996 TO BE
MASS: 59.5KG
SUPPLIED FOR EACH CASTING.
REV. No. DATE DESCRIPTION AUTH.
SEWERAGE STANDARD DRAWING GCCC LCC RCC QUU UW
SEQ WATER MAINTENANCE HOLE COVER
DRAWING No. VERSION

SERVICE PROVIDERS SEWER - CLASS B - CONCRETE INFILL SEQ-SEW-1308-2 A


TYPICAL FRAME DETAILS
WORK PRACTICES MUST COMPLY WITH ALL APPLICABLE ORG DATE:
OCCUPATIONAL HEALTH & SAFETY LEGISLATION NOT TO SCALE 1/1/2013
12 HIGH TEXT (TYPICAL) 30
2mm RECESSED

5
LETTERING
REFER NOTE 10 REFER NOTE 10
SE WER

AL)
5
VA

C
CU

(TYPI
U UM

3.2
U A
3.2 SECTION

SE
B AL -

W
REFER NOTE 10 - IC

ER
P

25
3.2
TY

A
8

58

8
33
3mm CHAMFER 40 33

TYPICAL EDGE DETAIL

LIFTING LIFTING
KEYHOLE KEYHOLE NOTES
REFER SEQ-SEW-1308-4
1. ALL EDGES TO BE SQUARE.
B 2. ALL EDGES TO BE ARRISED UNLESS SHOWN
- OTHERWISE.
3. ALL FILLETS TO BE 5mm RADIUS.
4. CASTING TO BE FREE OF BURRS AND PITS.
F41 FABRIC
5. MACHINE SURFACE SYMBOL 3.2

C L ASS D 6. MATERIAL: DUCTILE CAST IRON


B - S E ALE TENSILE STRENGTH: ISO 1083/JS/600-3/S (AS1831) HARDNESS: 190
- 270 (HB)
ULTIMATE DESIGN LOAD: 80 KN (AS3996)
7. TOLERANCES:
PLAN CAST DIMENSIONS
ANGLE PROFILE
MACHINED DIMENSIONS
25

N20 CONCRETE OVERALL MAJOR


DIAMETER OF COVER +0 -0.25mm
DFT OF COATING 50um
58

8. ALL MACHINED SURFACES SHALL HAVE A COATING APPROVED AS FIT


FOR THE PURPOSE OF PROVIDING A RUST PROOF, NON-STICK AND
GAS/WATER PROOF JOINT.
9. ALL NON MACHINED SURFACES TO BE BITUMINOUS COATED IN
40 33 33 40 ACCORDANCE WITH AS 3750-4.
10. IDENTIFICATION TAGS "SEWER" AND "VACUUM SEWER" TO BE
REMOVED AS REQUIRED. SERVICE PROVIDER NAME WHERE REQUIRED.
11. ALL WORK SHALL BE IN ACCORDANCE WITH CURRENT QUEENSLAND
SECTIONAL ELEVATION B CODE, SPECIFICATIONS AND STANDARDS.
- 12. COVERS AND FRAMES TO BE SUPPLIED ASSEMBLED.
13. CERTIFICATION OF COMPLIANCE TO A.S. 3996 TO BE SUPPLIED FOR
MAINTENANCE HOLE COVER EACH CASTING.
FOR USE IN NON TRAFFICABLE LOCATIONS
MASS: 25KG CASTING
58KG CASTING/CONCRETE INFILL

REV. No. DATE DESCRIPTION AUTH.


SEWERAGE STANDARD DRAWING GCCC LCC RCC QUU UW
SEQ WATER MAINTENANCE HOLE COVER
DRAWING No. VERSION

SERVICE PROVIDERS SEWER - CLASS B - CONCRETE INFILL SEQ-SEW-1308-3 A


TYPICAL COVER DETAILS
WORK PRACTICES MUST COMPLY WITH ALL APPLICABLE ORG DATE:
OCCUPATIONAL HEALTH & SAFETY LEGISLATION NOT TO SCALE 1/1/2013
B
-

85

55

22 16
6
R1
3
R3
A A

17
- 66 -

B
-

PLAN

10 RECESS FOR 32
CONCRETE BONDING
30 15 17

12
15
25

3mm CHAMFER
40 33 10

SECTION A SECTION B
- - REFER SEQ-SEW-1308-3 FOR NOTES

KEYHOLE DETAIL

FOR USE IN NON TRAFFICABLE LOCATIONS

REV. No. DATE DESCRIPTION AUTH.


SEWERAGE STANDARD DRAWING GCCC LCC RCC QUU UW
SEQ WATER MAINTENANCE HOLE COVER
DRAWING No. VERSION

SERVICE PROVIDERS SEWER - CLASS B - CONCRETE INFILL SEQ-SEW-1308-4 A


TYPICAL LIFTING HOLE DETAILS
WORK PRACTICES MUST COMPLY WITH ALL APPLICABLE ORG DATE:
OCCUPATIONAL HEALTH & SAFETY LEGISLATION NOT TO SCALE 1/1/2013
20 12
STIFFENER RIB 78 35
4 PLACES

STIFFENER RIB 55 10
R5 FILLET TO
TOP EDGES 3.2

3.

25
2
3.2

40

35
60

35
A

20
-

M8 TAPPED HOLE

3.2
METRIC COARSE THREAD
125

TYPICAL SECTION

A NOTES
- 1. ALL EDGES TO BE SQUARE.
R12.5
2. ALL EDGES TO BE ARRISED UNLESS
SHOWN OTHERWISE.
HOLD-DOWN SLOT 3. ALL FILLETS TO BE 5mm RADIUS UNLESS
4 PLACES - FOR
M-16 MASONRY ANCHORS SHOWN OTHERWISE.
4. CASTING TO BE FREE OF BURRS AND PITS.
25 5. MACHINE SURFACE SYMBOL 3.2

6. MATERIAL: GREY CAST IRON (AS1830)


TENSILE STRENGTH: ISO 185/JL/225
HARDNESS: 145 - 215 (HB)
ULTIMATE DESIGN LOAD: 210 KN (AS3996)
GAUGE SHALL BE USED TO CHECK PLAN 7. TOLERANCES:
PCD AND CLEARANCE HOLE POSITION CAST DIMENSIONS
ANGLE PROFILE
MACHINED DIMENSIONS
620 PCD OVERALL MAJOR
JIG DRILLED AND TAP 4-M8 DIAMETER OF COVER +0 -0.25mm
METRIC COARSE THREAD DFT OF COATING 50um
8. ALL MACHINED SURFACES SHALL HAVE A COATING APPROVED
AS FIT FOR THE PURPOSE OF PROVIDING A RUST PROOF,
NON-STICK AND GAS/WATER PROOF JOINT.
125 125 9. ALL NON MACHINED SURFACES TO BE BITUMINOUS COATED IN
UNITYWATER AND GCCC AND LOGAN WATER ACCORDANCE WITH AS 3750-4.
AND REDLAND WATER ACCEPTS ALL CLASS B 10. FRAME FIXED TO TOP SLAB WITH 4-M16 HEAVILY GALVANISED
COVERS AND FRAMES WITH CERTIFICATION MASONRY ANCHORS. AFTER ASSEMBLY ALL STEELWORK TO BE
TO AS 3996 AS DETAILED IN CLAUSE 3.2 PAINTED WITH AN APPROVED BITUMASTIC ENAMEL.
A 11. FOR SURCHARGE AREAS AND FOR OVERLAND FLOW AREAS
SECTIONAL ELEVATION FOR SEALS AND REGISTERS.
AND WHERE SPECIFIED IN THE DESIGN DRAWINGS, COVERS
- AND FRAMES TO BE SUPPLIED WITH 4-M8 COARSE THREADED
316 SS BOLTS 45mm LONG WITH NYLON WASHERS.
MAINTENANCE HOLE FRAME 12. ALL WORK SHALL BE IN ACCORDANCE WITH CURRENT
MASS: 59.5KG FOR USE IN NON TRAFFICABLE LOCATIONS QUEENSLAND CODE, SPECIFICATIONS AND STANDARDS.
13. COVERS AND FRAMES TO BE SUPPLIED ASSEMBLED.
14. CERTIFICATION OF COMPLIANCE TO A.S. 3996 TO BE
SUPPLIED FOR EACH CASTING.
REV. No. DATE DESCRIPTION AUTH.
SEWERAGE STANDARD DRAWING GCCC LCC RCC QUU UW
SEQ WATER MAINTENANCE HOLE COVER
DRAWING No. VERSION

SERVICE PROVIDERS SEWER - CLASS B - BOLT DOWN SEQ-SEW-1308-5 A


TYPICAL FRAME DETAILS
WORK PRACTICES MUST COMPLY WITH ALL APPLICABLE ORG DATE:
OCCUPATIONAL HEALTH & SAFETY LEGISLATION NOT TO SCALE 1/1/2013
UNITYWATER AND GCCC AND LOGAN WATER
AND REDLAND WATER ACCEPTS ALL CLASS B
COVERS AND FRAMES WITH CERTIFICATION
LETTERING TO FINISH TO AS 3996 AS DETAILED IN CLAUSE 3.2
FLUSH WITH RAISED FACE FOR SEALS AND REGISTERS.
OF DIAMOND PATTERN

25
A
- SEWER LIFTING
KEYHOLE

100
25

25
25

14
14
56
0
R8

AL

AL
PIC

PIC
LIFTING

TY

TY
KEYHOLE REFER
SEQ-SEW-1308-7 A

R296
25
-

12
COVER PATTERN DETAIL
39 KG CLASS B SEALED
BOLTING RECESS
4 PLACES REFER FOR USE IN NON TRAFFICABLE LOCATIONS
SEQ-SEW-1308-7

NOTE: LETTERING TO BE RAISED 2mm


GAUGE SHALL BE USED TO CHECK 620
PCD AND CLEARANCE HOLE POSITION
PLAN OF TOP PLAN OF BOTTOM
9 AT EDGE

NOTES
1. ALL EDGES TO BE SQUARE. 8. ALL MACHINED SURFACES SHALL HAVE A COATING
RAISED APPROVED AS FIT FOR THE PURPOSE OF PROVIDING A
30 TYPICAL RIBS 5 AT CENTRE PATTERN 2. ALL EDGES TO BE ARRISED UNLESS
25

10 RUST PROOF,NON-STICK AND GAS/WATER PROOF


10

SHOWN OTHERWISE.
3. ALL FILLETS TO BE 5mm RADIUS UNLESS JOINT.
SHOWN OTHERWISE. 9. ALL NON MACHINED SURFACES TO BE BITUMINOUS
65

4. CASTING TO BE FREE OF BURRS AND PITS. COATED IN ACCORDANCE WITH AS 3750-4.


5. MACHINE SURFACE SYMBOL 3.2 10. FRAME FIXED TO TOP SLAB WITH 4-M16 HEAVILY
8 GALVANISED MASONRY ANCHORS OR CAST IN-SITU AS
R10500
5

6. MATERIAL: DUCTILE CAST IRON SHOWN IN DRAWINGS. AFTER ASSEMBLY ALL


35 TENSILE STRENGTH: ISO 1083/JS/600-3/S (AS1831) STEELWORK TO BE PAINTED WITH AN APPROVED
HARDNESS: 190 - 270 (HB) BITUMASTIC ENAMEL.
ULTIMATE DESIGN LOAD: 80 KN (AS3996) 11. FOR SURCHARGE AREAS AND FOR OVERLAND FLOW AREAS
7. TOLERANCES: AND WHERE SPECIFIED IN THE DESIGN DRAWINGS,
CAST DIMENSIONS _ 1.00mm
+ COVERS AND FRAMES TO BE SUPPLIED WITH 4-M8
SECTIONAL ELEVATION A _
+ COARSE THREADED 316 SS BOLTS 45mm LONG.
- MACHINED DIMENSIONS _ 0.125mm
+ 12. ALL WORK SHALL BE IN ACCORDANCE WITH CURRENT
OVERALL MAJOR QUEENSLAND CODE, SPECIFICATIONS AND STANDARDS.
DIAMETER OF COVER +0 -0.25mm 13. COVERS AND FRAMES TO BE SUPPLIED ASSEMBLED.
MAINTENANCE HOLE COVER
DFT OF COATING 50um 14. CERTIFICATION OF COMPLIANCE TO A.S. 3996 TO BE
MASS: 39KG
SUPPLIED FOR EACH CASTING.
REV. No. DATE DESCRIPTION AUTH.
SEWERAGE STANDARD DRAWING GCCC LCC RCC QUU UW
SEQ WATER MAINTENANCE HOLE COVER
DRAWING No. VERSION

SERVICE PROVIDERS SEWER - CLASS B - BOLT DOWN SEQ-SEW-1308-6 A


TYPICAL COVER DETAILS
WORK PRACTICES MUST COMPLY WITH ALL APPLICABLE ORG DATE:
OCCUPATIONAL HEALTH & SAFETY LEGISLATION NOT TO SCALE 1/1/2013
B
-

80
55

22 16 620 PCD

6
R1
R 28
3
R3
A A C C
17

26
66

- - - -
R2
8
R 13

B
- PLAN

PLAN

9 RAISED PATTERN
10 32 30
25 R28
25 15 17
R13

12

10

3.2

10
TOP OF PATTERN
25

37

25
15
3.2

3mm CHAMFER 3mm CHAMFER 35


38 70 56 3mm CHAMFER

SECTION A SECTION B SECTION C TYPICAL EDGE DETAIL


- - -

KEYHOLE DETAIL BOLT RECESS DETAIL

REFER SEQ-SEW-1308-6 FOR NOTES FOR USE IN NON TRAFFICABLE LOCATIONS

REV. No. DATE DESCRIPTION AUTH.


SEWERAGE STANDARD DRAWING GCCC LCC RCC QUU UW
SEQ WATER MAINTENANCE HOLE COVER
DRAWING No. VERSION

SERVICE PROVIDERS SEWER - CLASS B - BOLT DOWN SEQ-SEW-1308-7 A


TYPICAL COVER DETAILS
WORK PRACTICES MUST COMPLY WITH ALL APPLICABLE ORG DATE:
OCCUPATIONAL HEALTH & SAFETY LEGISLATION NOT TO SCALE 1/1/2013
20
STIFFENER RIB
4 PLACES

78 12 35

STIFFENER RIB 55
R5 FILLET TO 10
TOP FACE EDGES 3.2

3.2

25
A 3.2

40

35
-

60

35
20
M8 TAPPED HOLE

3.2
METRIC COARSE THREAD
125

A
- TYPICAL SECTION
R12.5

HOLD-DOWN SLOT NOTES


4 PLACES 1. ALL EDGES TO BE SQUARE.
2. ALL EDGES TO BE ARRISED UNLESS SHOWN
25 OTHERWISE.
3. ALL FILLETS TO BE 5mm RADIUS UNLESS
SHOWN OTHERWISE.
4. CASTING TO BE FREE OF BURRS AND PITS.
800 PCD 5. MACHINE SURFACE SYMBOL 3.2
6. MATERIAL: GREY CAST IRON (AS1830)
TENSILE STRENGTH: ISO 185/JL/225
GAUGE SHALL BE USED TO CHECK UNITYWATER AND GCCC AND LOGAN HARDNESS: 145 - 215 (HB)
PCD AND CLEARANCE HOLE POSITION PLAN WATER AND REDLAND WATER ONLY ULTIMATE DESIGN LOAD: 210 KN (AS3996)
ACCEPTS THIS CLASS D FRAME, RISER 7. TOLERANCES:
CAST DIMENSIONS +- 1.00mm
AND COVER SYSTEM OR EQUAL WITH +
620 PCD -
CERTIFICATION TO AS 3996. MACHINED DIMENSIONS +- 0.125mm
JIG DRILLED AND TAP 4-M8 OVERALL MAJOR
METRIC COARSE THREAD DIAMETER OF COVER +0 -0.25mm
DFT OF COATING 50um
FOR USE IN TRAFFICABLE ROADWAY 8. ALL MACHINED SURFACES SHALL HAVE A
LOCATIONS. THIS BASE FRAME SHALL BE COATING APPROVED AS FIT FOR THE
PURPOSE OF PROVIDING A RUST PROOF,
125 125 USED WITH THE 60 RISER RING SHOWN NON-STICK AND GAS/WATER PROOF JOINT.
IN SEQ-SEW-1308-9. 9. ALL NON MACHINED SURFACES TO BE
BITUMINOUS COATED IN ACCORDANCE WITH
AS 3750-4.
10. COVERS, FRAMES AND 60mm RISER RINGS
TO BE SUPPLIED ASSEMBLED.
11. ALL WORK SHALL BE IN ACCORDANCE WITH
SECTIONAL ELEVATION A CURRENT QUEENSLAND CODE, SPECIFICATIONS
AND STANDARD DRAWINGS.
- 12. CERTIFICATION OF COMPLIANCE TO A.S. 3996
TO BE SUPPLIED FOR EACH CASTING.
MAINTENANCE HOLE BASE FRAME
MASS: 59.5KG

REV. No. DATE DESCRIPTION AUTH.


SEWERAGE STANDARD DRAWING GCCC LCC RCC QUU UW
SEQ WATER MAINTENANCE HOLE COVER
DRAWING No. VERSION

SERVICE PROVIDERS SEWER - CLASS D - BOLT DOWN SEQ-SEW-1308-8 A


TYPICAL BASE FRAME DETAILS
WORK PRACTICES MUST COMPLY WITH ALL APPLICABLE ORG DATE:
OCCUPATIONAL HEALTH & SAFETY LEGISLATION NOT TO SCALE 1/1/2013
17 30

UNITYWATER AND GCCC AND LOGAN WATER


AND REDLAND WATER ONLY ACCEPTS THIS 3.2

40
CLASS D FRAME, RISER AND COVER SYSTEM

3.2
OR EQUAL WITH CERTIFICATION TO AS 3996

75
40

100
SEE SEQ-SEW-1308-8

50
3.2

75
3.2

60
35
25

25
BOLT HOLE AND RECESS 3.2
4 LOCATIONS

10
R13 3mm CHAMFER
B B
- 60mm RISER
- 12

3.2
MASS : 32KG

3.2
PROVIDE 4 ADDITIONAL
BOLT HOLES AND RECESS A A
FOR BOLT DOWN COVERS - -
WITH A M8 METRIC COARSE
THREAD. SEE 35mm RISER
NOTE 13 ON MASS : 27.5KG
SEQ-SEW-1308-10
PLAN OF BOLT RECESS

M8 COARSE THREAD
316 SS BOLTS

10

40
GAUGE SHALL BE USED TO CHECK FRAME (SEE

40
PCD AND CLEARANCE HOLE POSITION PLAN SEQ-SEW-1308-8

105
FOR DETAILS)

90

130
17 17

115
620 PCD

90
40

75
25

25

25
VARIES

SECTION A
-
75mm RISER 90mm RISER
TYPICAL ASSEMBLY MASS : 38KG MASS : 44KG

RISER HEIGHT VARIES (SEE DETAILS) 4 x BOLTS: 60mm LONG FOR 35mm RISER
90mm LONG FOR 60mm RISER REFER TO 35mm RISER FOR TYPICAL DIMENSIONS
SECTION B 100mm LONG FOR 75mm RISER TO ALL RISERS.
115mm LONG FOR 90mm RISER
-
ADDITIONAL BOLTS SEE NOTE 13 ON SEQ-SEW-1308-10

RISER RING FOR USE IN TRAFFICABLE


REFER SEQ-SEW-1308-10 FOR NOTES ROADWAY LOCATIONS.

REV. No. DATE DESCRIPTION AUTH.


SEWERAGE STANDARD DRAWING GCCC LCC RCC QUU UW
SEQ WATER MAINTENANCE HOLE COVER
DRAWING No. VERSION

SERVICE PROVIDERS SEWER - CLASS D - BOLT DOWN SEQ-SEW-1308-9 A


TYPICAL RISER RING DETAILS
WORK PRACTICES MUST COMPLY WITH ALL APPLICABLE ORG DATE:
OCCUPATIONAL HEALTH & SAFETY LEGISLATION NOT TO SCALE 1/1/2013
LETTERING TO FINISH
FLUSH WITH RAISED FACE
OF DIAMOND PATTERN

25
A
- SEWER

25
25
14

14
100
25

56
0
R8
LIFTING

AL
AL
KEYHOLE

PIC
PIC
LIFTING
KEYHOLE REFER

TY

TY
SEQ-SEW-1308-11
A
25 COVER PATTERN DETAIL
-

12
49 KG CLASS D SEALED
UNITYWATER AND GCCC AND LOGAN
BOLTING RECESS WATER AND REDLAND WATER ONLY
4 PLACES REFER ACCEPTS THIS CLASS D FRAME, RISER
SEQ-SEW-1308-11
AND COVER SYSTEM OR EQUAL WITH
CERTIFICATION TO AS 3996, SEE
LETTERING TO BE RAISED 2mm SEQ-SEW-1308-8

PLAN OF TOP PLAN OF BOTTOM


FOR USE IN TRAFFICABLE
ROADWAY LOCATIONS.
9 AT EDGE

NOTES
25 RAISED 1. ALL EDGES TO BE SQUARE.
TYPICAL RIBS 5 AT CENTRE PATTERN 8. ALL MACHINED SURFACES SHALL HAVE A COATING
10 2. ALL EDGES TO BE ARRISED UNLESS SHOWN
12

OTHERWISE. APPROVED AS FIT FOR THE PURPOSE OF PROVIDING A


3. ALL FILLETS TO BE 5mm RADIUS UNLESS RUST PROOF, NON-STICK AND GAS/WATER PROOF JOINT.
9. ALL NON MACHINED SURFACES TO BE BITUMINOUS
40

SHOWN OTHERWISE.
COATED IN ACCORDANCE WITH AS 3750-4.
95

4. CASTING TO BE FREE OF BURRS AND PITS.


10. COVERS, FRAMES AND 60mm RISER RINGS TO BE
5

5. MACHINE SURFACE SYMBOL 3.2


SUPPLIED ASSEMBLED.
6. MATERIAL: DUCTILE CAST IRON (AS1831) 11. ALL WORK SHALL BE IN ACCORDANCE WITH CURRENT
8 QUEENSLAND CODE, SPECIFICATIONS AND STANDARD
29 TENSILE STRENGTH: ISO 1083/JS/600-3/S
HARDNESS: 190 - 270 (HB) DRAWINGS.
ULTIMATE DESIGN LOAD: 210 KN (AS3996) 12. CERTIFICATION OF COMPLIANCE TO A.S. 3996 TO BE
7. TOLERANCES: SUPPLIED FOR EACH CASTING.
CAST DIMENSIONS _ 1.00mm
+ 13. FOR SURCHARGE AREAS AND FOR OVERLAND FLOW AREAS
SECTIONAL ELEVATION A _
+ AND WHERE SPECIFIED IN THE DESIGN DRAWINGS,
MACHINED DIMENSIONS _ 0.125mm
+ COVERS AND FRAMES TO BE SUPPLIED WITH 4-M8
- COARSE THREADED 316 SS BOLTS 45mm LONG WITH
OVERALL MAJOR
NYLON WASHERS.
MAINTENANCE HOLE COVER DIAMETER OF COVER +0 -0.25mm
MASS: 49KG DFT OF COATING 50um

REV. No. DATE DESCRIPTION AUTH.


SEWERAGE STANDARD DRAWING GCCC LCC RCC QUU UW
SEQ WATER MAINTENANCE HOLE COVER
DRAWING No. VERSION

SERVICE PROVIDERS SEWER - CLASS D - BOLT DOWN SEQ-SEW-1308-10 A


TYPICAL COVER DETAILS
WORK PRACTICES MUST COMPLY WITH ALL APPLICABLE ORG DATE:
OCCUPATIONAL HEALTH & SAFETY LEGISLATION NOT TO SCALE 1/1/2013
B

80
55

22 16
6 620 PCD
R1 3
R3 R28

A A C C
17
66

26
R2 R13
8

UNITYWATER AND GCCC AND LOGAN WATER AND


PLAN REDLAND WATER ONLY ACCEPTS THIS CLASS D PLAN

9 RAISED PATTERN
FRAME, RISER AND COVER SYSTEM OR EQUAL WITH
CERTIFICATION TO AS 3996 SEE SEQ-SEW-1308-8

25

20 R28
10 32

3.2

12
R13 TOP OF PATTERN

10
25 15 17

12

40
3.2
27

15
40

3mm CHAMFER
29
3mm CHAMFER
108 56

TYPICAL EDGE DETAIL


SECTION B SECTION C
- -
SECTION A
-
BOLT RECESS DETAIL
KEYHOLE DETAIL

REFER SEQ-SEW-1308-10 FOR NOTES FOR USE IN TRAFFICABLE


ROADWAY LOCATIONS.

REV. No. DATE DESCRIPTION AUTH.


SEWERAGE STANDARD DRAWING GCCC LCC RCC QUU UW
SEQ WATER MAINTENANCE HOLE COVER
DRAWING No. VERSION

SERVICE PROVIDERS SEWER - CLASS D - BOLT DOWN SEQ-SEW-1308-11 A


TYPICAL COVER DETAILS
WORK PRACTICES MUST COMPLY WITH ALL APPLICABLE ORG DATE:
OCCUPATIONAL HEALTH & SAFETY LEGISLATION NOT TO SCALE 1/1/2013

You might also like