Professional Documents
Culture Documents
C Centrifugal Pumps
with open impeller
Construction
Close-coupled centrifugal pumps with open impeller.
Free-flow impeller (vortex or recessed impeller) for type C 16/1E.
Applications
For moderately dirty liquids or emulsions.
For industry and agriculture.
Operating conditions
Liquid temperature from -10 °C to +90 °C.
Ambient temperature up to 40 °C.
Total suction lift up to 8 m.
Maximum permissible working pressure: 6 bar.
Maximum size of solids: 4 mm.
Continuous duty.
Motor
2-pole induction motor, 50 Hz (n ≈ 2900 rpm).
C: three-phase 230/400 V ± 10%.
CM: single-phase 230 V ± 10%, with thermal protector.
Capacitor inside the terminal box.
Insulation class F.
Protection IP 54.
Motor suitable for operation with frequency converter from 1,1 kW.
Materials Classification scheme IE3 for three-phase motors from 0,75 kW.
Component C B-C Constructed in accordance with: EN 60034-1; EN 60034-30-1.
Pump casing Cast iron Bronze EN 60335-1, EN 60335-2-41.
GJL 200 EN 1561 G-Cu Sn 10 EN 1982
Lantern bracket Cast iron Bronze Special features on request
GJL 200 EN 1561 G-Cu Sn 10 EN 1982 - Other voltages.
Impeller Brass P- Cu Zn 40 Pb 2 UNI 5705 - Frequency 60 Hz (as per 60 Hz data sheet).
Shaft Chrome steel - Protection IP 55.
1.4104 EN 10088 (AISI 430) Cr-Ni-Mo steel - Special mechanical seal
Chrome-nickel steel 1.4401 EN 10088 - Higher or lower liquid or ambient temperatures.
1.4305 EN 10088 (AISI 303) (AISI 316) - Motor suitable for operation with frequency converter up to 0,75 kW.
for C 41 - Construction with bearing bracket.
Mechanical seal Carbon - Ceramic - NBR
U.S. g.p.m. 4 6 8 10 20 30 40 50 60 70
30
H
m 80
C 41 H
C 22 ft
20
C 22/1 C4 60
C 4/1
C 20 40
10
C 16/1 20
0 0
0.5 m3/h 1 2 3 4 5 10 15 18
Q l/min
10 20 30 40 50 100 200 300
72 892 C
181
C Centrifugal Pumps
with open impeller
182
C Centrifugal Pumps
with open impeller
266 263
34 l1 l2
33
G1 l3
G 1/2 122 ISO 228
ISO 228
ISO 228
ISO 228
G 1/2
G1
h2
75
160 160
8 63 h4 8 63
4.93.221 4.93.222
7 22
7 22
93 80 100
88 80 100
96 122 96 122
mm kg
TYPE kg TYPE kg TYPE
h2 h4 l1 l2 l3 C CM
C 16/1E 5,2 B-C 16/1E 5,6 C 20E 90 5 67 82 60 6,8 6,8
CM 16/1E 5,2 B-CM 16/1E 5,6 C 22/1E - C 22E 110 17 77 94 71 8 - 8,3 8 - 8,3
fM
a l1 l2
DN 2 l3
DN 1
h2
h4 HA h1
4_93_223
K AA
w B A
BB AB
DN1 DN2 mm kg
TIPO
TYPE
ISO 228 a fM h1 h2 H h4 BB B AB A AA K l1 l2 l3 w HA C CM B-C B-CM
– B-C 20/A G1 G1 35 303 71 90 182 - 106 90 134 112 22 7 70 84 60 105 10 - - 9,1 9,1
183
C Centrifugal Pumps
with open impeller
Hm
25 15
H ft
H ft
η 56%
28 14 11
35
4 30 13 54
η 31% 10
12
9 30
11
3 10 8
0 3 0.5 1 1.5 2 2.5 0 3 1 2 3 4 5
Q m /h Q m /h
0 l/min 10 20 30 40 0 l/min 20 30 40 50 60 70 80
0 l/s 0.1 0.2 0.3 0.4 0.5 0.6 0 l/s 0.2 0.4 0.6 0.8 1 1.2
0.1 0.3 0.4
P kW
0.1 0.3
0.2
P kW
P HP
P HP
0.05 0.2
0.1
0.1
0 0 0 0
72.126
0 Q m3/h 0.5 1 1.5 2 2.5
4
12
NPSH m
3 10
NPSH ft
8
2 6
1 4
2
0 72.121
0
0 Q m3/h 1 2 3 4 5
0 U.S. g.p.m. 10 20 30
25
80
C 22
C 22 Ø 119.5
20
35
40
44
C 22/1 70
46
C 22/1 Ø 116 47 60
46
Hm
44 50
H ft
15
40
η 49% 35
40
10
30
20
5
0 3
Q m /h 1 2 3 4 5 6 7
0 l/min 20 40 60 80 100
0.5
P HP
C 22/1
0.6
0.4
0.5
0.3 0.4
0.2 0.3
4
12
NPSH m
3 10
NPSH ft
8
2 6
1 4
2
0 0
72.123
0 Q m3/h 1 2 3 4 5 6 7
184
C Centrifugal Pumps
with open impeller
Hm
H ft
H ft
65
40 40
60
10 10
55 30 30
20 20
5 5
0 3 5 10 15 0 3 5 10 15
Q m /h Q m /h
0 l/min 50 100 150 200 250 300 0 l/min 50 100 150 200 250 300
0 l/s 1 2 3 4 5 0 l/s 1 2 3 4 5
1.0 1.0
1.2 1.2
0.8 0.8
1.0 1.0
P kW
P kW
P HP
0.4 0.6 0.4 0.6
0.4 0.4
0.2 0.2
0.2 0.2
0 0 0 0
8 25 8 25
NPSH m
NPSH m
6 20 6 20
NPSH ft
NPSH ft
15 15
4 4
10 10
2 2
5 5
0 0 0 0
72.124.1 72.124.2
0 Q m3/h 5 10 15 0 Q m3/h 5 10 15
0 U.S. g.p.m. 20 30 40 50 60 70
25
80
Ø 124 40 50
54 C 41
58
70
η 59.5%
20
58
60
Hm
H ft
15 50
40
10
0 3 5 10 15
Q m /h
0 l/min 100 200 260
0 l/s 1 2 3 4
1.2 1.6
1.0 1.4
P kW
1.2
P HP
0.8
1.0
0.6 0.8
0.6
0.4
6
NPSH m
15
NPSH ft
4
10
2
5
0 0
72.125
0 Q m3/h 5 10 15
185
C Centrifugal Pumps
with open impeller
Features
3.94.058
Flexible
The option to choose between cast iron and bronze materias for the hydraulic
parts in contact with the pumped liquid allows C series pumps to be selected for
use with different types of liquids.
Solid parts
The open impeller allows for the passage of suspended solids in pumped liquid.
Reliable
The bearing and shaft are designed to ensure the reduction of the stress, provi-
ding high reliability under all operating conditions.
186