Performance Data
Service PRP (1) ESP (2)
Model C75D6
Power (kVA) 68 75
Engine brand Cummins
Power (kW) 54 60
Engine model 4BTA3.9G2
Rated speed ( r.p.m) 1800
Speed control type Electronic
Standard voltage (V) 400/230V
Phase 3
Rated at power factor(cos phi) 0.8
Control system Digital
Star ter motor voltage 24V
AU VE
RI
BURE

ISO 9001
TA S

BUREAU VERITAS
Certification
182 8
Frequency 60HZ
Engine speed (RPM) 1800
AGG Power gensets are compliant with ISO 9001 and CE standard, which include the
following directives: 100% standby power 31.3
·2006/42/EC Machinery safety. Fuel 28.5
100% prime power
·2006/95/EC Low voltage Consumption
·EN 60204-1: 2006+A1: 2009, EN ISO 12100: 2010, EN ISO 13849-1: 2008, EN 75% prime power 20.7
12601 : 2010 (L/H)
50% prime power 14.4
(1) PRP (Prime Power):
According to ISO8528-1, prime power is the maximum power available during a variable
Standard reference Conditions
power sequence, which may be run for an unlimited number of hours per year, between
Note: Standard reference condition 25℃ (77℉) air inlet temp, 100m(328ft) A.S.L 30%
stated maintenance intervals. The permissible average power output during at 24 hours
relative humidity. Fuel consumption dat with diesel fuel with specific gravity of 0.85 and
period shall not exceed 80% of the prime power. 10% overload available for governing
conforming to BS 2869: 1998, Class A2
purposes only.

(2) ESP (Standby Power):


L L
According to ISO 8528-1, It is defined as the maximum power available, under the
agreed operating conditions, for which the generating set is capable of delivering for up
to 500 hours of operation per year (of which no more than 300 hours for continuative H
H
use) with the maintenance intervals and procedures being carried out as prescribed by W
W
the manufacturers. No overload capability is available.

Dimension and Weight


Dimension Open Silent
Powers ESP PRP Standby
Length (L) 2060mm 2680mm
Voltage (V) KVA KW KVA KW Amps
Width (W) 810mm 1100mm
480/277 75 60 68 54 90.2
Height (H) 1410mm 1732mm
440/254 75 60 68 54 98.4 Net Weight 820KG 1423KG
400/230 75 60 68 54 108.3 Fuel Tank (L) 190 220

380/220 75 60 68 54 114.0

220/127 75 60 68 54 196.8
www.aggpower.com
Your professional power assistant

Engine Specification: 4BTA3.9G2

Basic technical data Air intake system

No. of cylinders 4 Maximum intake air restriction

Cylinder arrangement In-line with heavy duty air cleaner:

Cycle 4 stroke -Dir ty element 6kpa

Induction system Turbocharger -Clean element 4kpa

Compression ratio 17.3:1

Bore 102mm Lubrication system

Stroke 120mm Engine oil pressure for engine

Displacement 3.9L protection devices:

Engine idle speed 950-1050 RPM — Idle speed(Minimum ) 207kPa

Approximate engine weight 355kg — Governed speed(Maximum ) 345kPa

Maximum oil temperature 121 ℃

Minimum required lube system

capacity-sump plus filters 10. 9L


Cooling system

Coolant capacity-engine 8.3L

Maximum coolant friction Electrical system

head external to engine: Cranking motor (Heavy duty,

-1800 rpm 35kPA positive engagement 24V

-1500 rpm 28kPA Battery charging system,

Maximum static head of coolant negative ground 40 ampere

above engine crank centerline 14m Maximum allowable resistance

Standard Thermostat of cranking circuit 0.002 ohm

(Modulating) Range 82 - 95℃ Minimum recommended battery

Minimum Pressure Cap 69 kPa capacity- cold soak 400 CCA

Maximum Top Tank Temperature

for Standby / Prime Power 104 / 100℃


General installation Prime power

Gross engine power output 67kw

Piston speed 7.2 m/s


Fuel system Friction horsepower 11.9kW
Injection system BYC PB Direct Injection
Engine water flow to engine 2.2l/sec
Governor type Electronic
Intake air flow 78 l/sec
Maximum restriction at lift pump 102 mmHg
Exhaust gas flow 206 l/sec
Maximum fuel inlet temperature
Exhaust gas temperature 510 ℃
Total drain flow
Radiated heat to ambient 16.4
(constant for all loads) 30 litre/ hour
Heat rejection to coolant 32.9 kW

Heat rejection to fuel TBD

www.aggpower.com
Your professional power assistant

Alternator Specification
Emergency voltage curve

Sudden increase warp


Alternator Sudden voltage warp Sudden decrease warp
520
Number of phase 3

Power factor (Cos Phi) 0.8 464

+1%
Poles 4 408 +1%
380
380
-1%
Winding Connections (standard) Star-serie 352

Terminals 12 296

Insulation type H class 240


0 1 2 3 4 5 6 7 8 9 10 11 12
δu%: -18.18 1.95s
Winding Pitch 2/3 δu%: 8.89
Benchmark phase: A
Benchmark phase: A
Min. voltage: 310.9V Recovery time:
Recovery time: 0..12ss
Max. voltage: 413.8V

IP rating IP23

Excitation system Self-excited

Bearing Single bearing Emergency frequency curve


Coating Vacuum impregnation Sudden increase warp
Sudden voltage warp Sudden decrease warp
70
Voltage regulator A.V.R

Couping Flexible disc 62

54 +1%
50
-1%
+1%
50
-1%
46

38

30
0 1 2 3 4 5 6 7 8 9 10 11 12
δf%%: -10.64 Benchmark phase: A Min. frequency: 44.68Hz Recovery time: 1..95s
Three phase Reliable Single phase
δf%%: 7.74 Benchmark phase: A Max. frequency: 53.87Hz Recovery time: 0..54s

Options

Engine Alternator Generator Sets Fuel System

· Water Jacket · Winding Temp measuring · Tools with the machine · Low fuel level alarm
Pre-heater Instrument · Extended range fuel tank · Automatic fuel
· Fuel heater · Alternator Pre-heater · Bunded fuel tank feeding system
· PMG · Fuel T-valves
· Anti-damp and anti-corrosion
treatment
· Anti-condensation heater
· Winding and bearing RTD

Canopy Lub oil system Cooling System Control Panel

· Rental type · Oil Pre-heater · Front heat protection · Remote control panel
Canopy · Oil temp sensor · ATS
· Trailer · Synchronizing controller
· Adjustable ear th leakage
relay

www.aggpower.com
Your professional power assistant

Control Panel

Configuration Benefits

· Emergency stop button · Less wiring and components


· Integrated solution
· Protection MCB
· Less engineering and programming
· Battery charger · User friendly set-up and button layout
· Integrated aviation plug · Module can be configured to suit individual applications
· ATS connection · PC software for simplified configuration
· Digital control module · Wide range of communication capabilities

Operation conditions
Features
· Operation temp: -20 ˚C to + 70 ˚C
· 3 phase generator set monitoring
· Storage temp: -30 ˚C to + 80 ˚C
· S uppor t of engines equipped with electronic control
· Operating humidity: 95% w/o condensation
unit
· Vibration: 5-25Hz, ±1.6 mm
· Comprehensive diagnostic message
5-1 00 Hz , a= 4g
· A utomatic or manual star t / stop of the gensets
· Shocks: a= 500m/s²
· Push buttons for simple control , lamp test
· G raphic back - lit LCD display
Options
· Parameters adjustable via keyboard or PC
· Mains measurements ( 50HZ / 60HZ ) · Ethernet interface (Remote monitoring and control)
· Generator measurements ( 50HZ / 60HZ ) · GSM modem/wireless internet (Remote monitoring and control)
· Comprehensive shutdown or warning on fault condition · RS232-RS485 Dual por t interface
· 3 phase Generator protections · Synchronizing control panel
· Distribution board with sockets kit and power busbar
- Over - / under voltage
· Battery trickle charge ammeter
- Over - / under frequency
· Ear th leakage protection
- Current / voltage asymmetry · Ear th fault protection
- Over current / overload · Low fuel level alarm
· 3 phase AMF function · Low fuel level shutdown
- Over-/under frequency · High fuel level alarm
- Over-/under voltage · Fuel transfer system control
- Voltage asymmetry · Low coolant level shutdown
· Configurable analog inputs · High lube oil temp shutdown
· Battery voltage, engine speed (pick-up) measurement · Overload via alarm switch on breaker
· Configurable programmable binary inputs and outputs · Engine coolant heater controls
· Warm-up and cooling functions · Control panel heater
· Generator C.B. and Mains C.B. control with feedback · S peed adjust switch
and return timer
· Oil temp displayed on LCD screen
· RS232 interface
· Additional 8 inputs and outputs
· Modem communication suppor t
· Hours counter
· Sealed to Ip65
· Event log
Publication No. GYH0517N, ISSUE 1 @ AGG

Distributed by

AGG UK | AGG China | AGG USA | AGG UAE


info@aggpower.com | www.aggpower.com

All information in the document is substantially correct a the time of printing


but may be subsequently altered by the company.

You might also like