50 Hz
35 kVA Industrial Spark-Ignited Generator Set
Generac International Products
5.4L
Powering Ahead
For over 50 years, Generac has provided innovative design and superior manufacturing.
Generac ensures superior quality by designing and manufacturing most of its generator components, including
alternators, enclosures and base tanks, control systems and communications software.
Generac’s gensets utilize a wide variety of options, configurations and arrangements, allowing us to meet the
standby power needs of practically every application.
Generac searched globally to ensure the most reliable engines power our generators. We choose only engines
that have already been proven in heavy-duty industrial applications under adverse conditions.
Generac is committed to ensuring our customers’ service support continues after their generator purchase.
SG/PG Series
50 Hz
Standard Features
ENGINE SYSTEM ALTERNATOR SYSTEM ENCLOSURE
General Class H insulation material Rust-proof fasteners with nylon washers to
Oil Drain Extension 2/3 Pitch protect finish
Air Cleaner Skewed Stator High performance sound-absorbing material
Fan Guard Brushless Excitation Gasketed doors
Stainless Steel flexible exhaust connection Sealed Bearings Stamped air-intake louvers
Critical Exhaust Silencer (enclosed only) Amortisseur winding Air discharge hoods for radiator-upward
Factory Filled Oil Full load capacity alternator pointing
Stainless steel lift off door hinges
Fuel System Stainless steel lockable handles
Primary and Secondary Fuel Shutoff GENERATOR SET Rhino Coat™ - Textured polyester powder coat
Flexible Fuel Line - NPT Connection
Internal Genset Vibration Isolation
Separation of circuits - high/low voltage
Cooling System
Separation of circuits - multiple breakers
Closed Coolant Recovery System
Wrapped Exhaust Piping (enclosed only)
UV/Ozone resistant hoses
Standard Factory Testing
Factory-installed Radiator
2 Year Warranty (Standby rated units)
50/50 Ethylene glycol antifreeze
1 Year Warranty (Prime rated units)
Silencer mounted in the discharge hood
Engine Electrical System
(enclosed only)
Battery charging alternator
Battery Cables
Battery Tray
Solenoid activated starter motor
Rubber-booted engine electrical connections
CONTROL SYSTEM
All Phase Currents Alarms
Oil Pressure Oil Pressure (Pre-programmable Low Pres-
Coolant Temperature sure Shutdown)
Coolant Level Coolant Temperature (Pre-programmed High
Engine Speed Temp Shutdown)
Battery Voltage Coolant Level (Pre-programmed Low Level
Frequency Shutdown)
Date/Time Fault History (Event Log) Low Fuel Pressure Alarm
Isochronous Governor Control Engine Speed (Pre-programmed Over speed
Control Panel Shutdown)
Waterproof/sealed Connectors
Digital H Control Panel - Dual 4x20 Display Battery Voltage Warning
Audible Alarms and Shutdowns
Programmable Crank Limiter Alarms & warnings time and date stamped
Not in Auto (Flashing Light)
7-Day Programmable Exerciser Alarms & warnings for transient and steady
Auto/Off/Manual Switch
Special Applications Programmable PLC state conditions
E-Stop (Red Mushroom-Type)
RS-232/485 Snap shots of key operation parameters dur-
Customizable Alarms, Warnings, and Events ing alarms & warnings
All-Phase Sensing DVR
Modbus protocol Alarms and warnings spelled out (no alarm
Full System Status
Predictive Maintenance algorithm codes)
Low Fuel Pressure Indication
Sealed Boards
2-Wire Start Compatible
Password parameter adjustment protection
Power Output (kW)
Single point ground
Power Factor
15 channel data logging
kW Hours, Total & Last Run
0.2 msec high speed data logging
Real/Reactive/Apparent Power
Alarm information automatically comes up
All Phase AC Voltage on the display
SG/PG Series
50 Hz
Configurable Options
ENGINE SYSTEM CIRCUIT BREAKER OPTIONS CONTROL SYSTEM
General Main Line Circuit Breaker 21-Light Remote Annunciator
Engine Block Heater 2nd Main Line Circuit Breaker Remote Relay Panel (8 or 16)
Air Filter Restriction Indicator Shunt Trip and Auxiliary Contact Oil Temperature Sender with Indication /
Stone Guard (Open Set Only) Electronic Trip Breakers Alarm
Critical Exhaust Silencer (Open Set Only) Remote E-Stop (Break Glass-Type, Surface
Mount)
Engine Electrical System
Remote E-Stop (Red Mushroom-Type,
10A battery charger
Surface Mount)
Remote E-Stop (Red Mushroom-Type,
ALTERNATOR SYSTEM ENCLOSURE
Flush Mount)
Weather Protected Remote Communication - Modem
Alternator Upsizing
Level 1 Sound Attenuation 10A Run Relay
Anti-Condensation Heater
Level 2 Sound Attenuation
Tropical coating
Steel Enclosure
Aluminum Enclosure
GENERATOR SET
12 VDC Enclosure Lighting Kits
Door Alarm Switch
Gen-Link Communications Software
(English Only)
Extended Factory Testing (3 Phase Only)
Pad Vibration Isolators
150 MPH Wind Kit
Engineered Options
ENGINE SYSTEM GENERATOR SET CONTROL SYSTEM
Coolant heater ball valves Special Testing Spare inputs (x4) / outputs (x4) - H Panel
Fluid containment pans Battery Box Only
Battery Disconnect Switch
ALTERNATOR SYSTEM ENCLOSURE
Rating Definitions
Standby – Applicable for a varying emergency load for the duration of a utility power outage with no overload capability. (Max. load factor = 70%)
Prime – Applicable for supplying power to a varying load in lieu of utility for an unlimited amount of running time. (Max. load factor = 70%) A 10% overload
capacity is available for 1 out of every 12 hours. The Prime Power option is only available on International applications.
Power ratings in accordance with ISO 8528-1, Second Edition dated 2005-06-01, definitions for Prime Power (PRP) and Emergency Standby Power (ESP).
SG/PG Series application and engineering data
50 Hz
ENGINE SPECIFICATIONS
ALTERNATOR SPECIFICATIONS
50 Hz
POWER RATINGS – NATURAL GAS/PROPANE VAPOR
Standby Prime
Single-Phase 110/220 VAC @1.0pf 28 kVA / 28 kW 127 Amps 22 kVA / 22 kW 100 Amps
Three-Phase 231/400 VAC @0.8pf 35 kVA / 28 kW 51 Amps 28 kVA / 22 kW 40 Amps
*Fuel supply installation must accommodate fuel consumption rates at 100% load.
COOLING
Standby Prime
Air Flow (inlet air combustion and radiator) ft3/min (m3/min) 1968 (55.8) 1968 (55.8)
System Coolant Capacity Gal (Liters) 3 (11.36) 3 (11.36)
Heat Rejection to Coolant BTU/hr 119,520 99,202
Max. Operating Ambient Temperature ºF (ºC) 104 (40) 104 (40)
Maximum Radiator Backpressure in H2O 0.5 0.5
ENGINE EXHAUST
Deration – Operational characteristics consider maximum ambient conditions. Derate factors may apply under atypical site conditions. Please consult a Generac Power Systems Industrial Dealer for
additional details. All performance ratings in accordance with ISO3046, BS5514, ISO8528 and DIN6271 standards. All power ratings are +/- 5%.
SG/PG Series dimensions and weights
50 Hz
STANDARD ENCLOSURE
L x W x H in (mm) 94.8 (2408.9) x 38 (965.1) x 49.5 (1258.1)
Steel: 2100 (952)
Weight lbs (kg)
Aluminum: 1754 (795)
Specification characteristics may change without notice. Please consult a Generac Power Systems Industrial Dealer for detailed installation drawings.