Professional Documents
Culture Documents
Model Echelon
PRODUCT SPECIFICAITON
Tokyo, Japan
D1E-BM5291-2
Page
1. Technical Specifications.................................................................................................................. 1
(1) 1 D1E-BM5291
1. Technical Specifications
1.1 Standard system configuration
(1) Gantry
- Alarm Box
- Remote Switch
- PC unit
- Switch unit
- LCD monitor
- Keyboard
- Multiple tap unit
- Phantom set
- Patient immobilizing pads and straps
-1- D1E-BM5291
1.2 Options
(1) Optional receiver coils
(4) Spectroscopy
(9) Fluoroscopy
(21) TIGRE
(22) 3D QEIR
-2- D1E-BM5291
2. System Specification
2.1 Power specification
(1) Voltage 3 phase AC 380, 400, 415V(50Hz)
3 phase AC 460, 480V(60Hz)
(4) Imaging applications (a) Spin echo (Proton density image, T1, T2 weighted
image)
(b) Inversion recovery image (T1 weighted image)
(c) Gradient echo image (T1, T2* weighted image)
(d) Fast spin echo (Proton density image, T1, T2 weighted
image)
(e) Fast inversion recovery image (T1, T2 weighted
image)
(f) MR Angiography image
(g) EPI image
(8) Reconstruction matrix 64 × 64, 128 × 128, 256 × 256, 512 × 512, 1024 × 1024,
2048 × 2048
-3- D1E-BM5291
(12) Field of view 5 ~ 500mm
-4- D1E-BM5291
2.3 Image display / processing function
(1) Display matrix 1024 × 1024
(Maximum value depends on monitor model)
-5- D1E-BM5291
(7) Post-processing
-6- D1E-BM5291
(h) Diffusion analysis (option)
Image type (1 Axis)
- ADC
Image type (3 Axes)
- ADC A-P
- ADC R-L
- ADC H-F
- ADC trace
- DWI trace
Image type (Isotropic DWI) (6,7,13,21 Axes)
FA
MD
DWI trace
Multiple slice support
-7- D1E-BM5291
(11) WW/ WL tool Mouse control (WW&WL, WW, WL)
Slider bar control
Auto window
Invert gray scale
Reset to prior state
ROI Window level jump
Non-linear WW / WL
Color WW / WL control
Access presets
(12) Magnify/Shift tool Mouse control (Zoom in, Zoom out, Shift)
Slider control
Magnify glass
Reset
-8- D1E-BM5291
(20) Scroll tool Next / Previous image
Next / Previous page
Syncro mode
Image sort
2.4 Magnet
(1) Type Super conductive magnet
(2) Field strength 1.5 tesla
(3) Leakage flux (0.5mT) 2.5m × 4.0m (Radially × Axially)
(4) Shimming technique Passive iron shim and gradient coil mounted active resistive
shim coils
(5) Cryogen boil off Zero boil off
(Depends on operating condition of device)
2.5 Gantry
(1) Dimensions Length 1.6m
Width 2.1m
Height 2.2m
Bore diameter 61cm
-9- D1E-BM5291
2.7 Patient table
(1) Range of vertical motion 495mm ~ 852mm
(6) Automatic move Available from table control panels (hold type operation)
The position set by light marker will be moved automatically
into the center position of magnetic field.
(4) MOD(option) 2.6GB, 2.3GB, 640MB legacy image data (Read only)
(5) LCD monitor 24 inch LCD color display
(4) Image reconstruction control processor (RCN PC) CPU : Pentium4 at 3.4GHz
Memory 2GB
- 10 - D1E-BM5291
2.10 GCPA unit
(1) Peak current 550A
- 11 - D1E-BM5291
2.13 Equipment sizes
Operator Console
PC unit 220 455 475
Switch unit 225 190 50
4
LCD monitor 566 230 480 36
Key board 452 173 50
Multiple tap unit 222 200 63
400
7 Sense unit 800 1,060 65
514
(Base part)
8 Helium compressor 442 529 532 100
820 1,445
(Equipment room) (Equipment room)
9 Filter box 447 85
910 1,550
(Scan room) (Scan room)
- 12 - D1E-BM5291
3. Equipment specification
3.1 Environmental condition for each room
Gantry
Scan room Patient Table 2,554 10,168 20 ~ 24 45 ~ 60
Filter Box
Operation
Operator Console 1,157 4,606 18 ~ 26 20 ~ 60
room
RFIP Unit
Equipment GCPA Unit
8,887 35,384 18 ~ 26 20 ~ 60
room Sense Unit
Helium Compressor
- 13 - D1E-BM5291
3.2
Unit mm
Weight Gantry 5,150kg
Patient table 500kg
Equipment Dimension
- 14 -
Gantry / Patient table
D1E-BM5291
Multiple tap
Mouse
Key board
LCD monitor
Switch unit
PC unit
Unit mm
Weight 36kg
Operator Console
- 15 - D1E-BM5291
1880 725 900
1880 Rear
Front
820 1000
1880
RFIP Unit
Unit mm
Weight 550kg
- 16 - D1E-BM5291
1060
400
800 514
Unit mm
Weight 65kg
SENSE Unit
- 17 - D1E-BM5291
532
442
529
Unit mm
Weight 100kg
Helium Compressor
- 18 - D1E-BM5291
910
1550
Unit mm
Weight 85kg
Filter Box
- 19 - D1E-BM5291
3.3 Incidental facilities
The following incidental facilities should be prepared by customer.
(5) Cryogen exhaustion Provision shall be made for rapid exhaustion of gaseous
Helium
- 20 - 21 D1E-BM5291