No.
PT : 037-CI/SMU/V/2018
Time Sheet No : -
LIQUID PENETRANT EXAMINATION REPORT
Job/Contract No. : Report No. : 037/V/18
Project : JKT NEW CONSTRUCTION PROJECT Ref. Drawing No. : DWG/CI-TI/045/18
Customer : PT. Sarana Utama Adimandiri Material Examined : Galvanis
Lighting Equipment : Philips 500 watt Ilumination Level : ≥1000 wat
Surface Equipment : As Welded Ground Flush Other ( )
√
Stage of Examination : After Welding After Excavation Other ( )
Welding Process : SMAW √ GTAW Other ( )
Scope of Examination : Base Material Weldment
√ Other ( )
Penetrant Type : Water Washable ( √ ) Application By
: Solvent Removable ( ) Brushing Spraying Other ( )
: Post Emulsifiable ( ) Dwell Time : ……………………10………………………….. Min
√ √
Penetrant : Flourescent Colors Contrast
Developer Type : Dry Developer Aqueous Dev. Non Aqueous Dev.
√
Developer Time : ……………………10………………………….. Min Procedure No. :
Cleaner Type : Application Code :
Welder
Part Identification Joint No. Length Examined Type of Result Remark
Code Discontinuity
BS 7 (WD-02) J 13 AGUS SW 3830 mm WD - ACC
AR 6 (WD-02) J 13 AGUS SW 3830 mm WD - ACC
AR 13 (WD-02) J 25 AGUS SW 1915 mm WD - ACC
AR 13 (WD-02) J 24 AGUS SW 3830 mm WD - ACC
BS 10 (WD-02) J 19 AGUS SW 3830 mm WD - ACC
BS 10 (WD-02) J 20 AGUS SW 3830 mm WD - ACC
- ACC
SKETCH
AR 6 AR 13
J 13 J 24 J 25
BS 10 BS 7
J 19 J 20 J 19 J 20
Examined by, Reviewed /Witnessed by Reviewed /Witnessed by Reviewed /Witnessed by
PENETRANT TEST PICTURE
CIRCUMFERENCE WELD - 1 (UPPER)
PENETRANT TEST PICTURE
PROJECT : JKT NEW CONSTRUCTION PROJECT
SERIAL NUMBER : 001
Tag Number :
DATE OF TEST -
CIRCUMFERENCE WELD - 2 (BOTTOM)
PENETRANT TEST PICTURE
PROJECT : JKT NEW CONSTRUCTION PROJECT
SERIAL NUMBER : 001
Tag Number :
DATE OF TEST
LONGITUDINAL WELD
PENETRANT TEST PICTURE
PROJECT : JKT NEW CONSTRUCTION PROJECT
SERIAL NUMBER : 002
Tag Number :
DATE OF TEST
CIRCUMFERENCE WELD - 1 (UPPER)