Mk7C
– Class 1 and Class 2
Key Features
Mk7C
- Class 1 and Class 2
163.5mm (H) 51mm (D)
Standards and Compliance Real-time Clock Time of Use • Option for passive RS-232
• Class 1 and Class 2 • Accuracy (internal) within 15 seconds • Up to 8 rates plus unified rate • UDP/IP GPRS/PPP capable
• IEC 62052-11, 62052-21,*62052-31, per month at 23˚C • Up to 32 separate import and export • Compatible with MV-90™ and PLC
62053-21, 62053-23 registers
• AS 62052.11, 62052.21, 62053.21, Data Memory • Daily, weekly, monthly, yearly and special Protocol
62053.23 • Up to 2 MB of non-volatile memory days • EDMI command line
• NMI M6 • Up to 200 programmable special days • DLMS
Display
• Up to 61 previous billing periods plus • MODBUS
Measurement • Large 7 segment display billing totals
• 1 phase 2 wire • Display digit size: 9.3mm x 4.35mm • Block or rolling maximum demand
• Up to 60 user-defined screens of any • Time of maximum demand
Voltage meter parameter Software
• Energy, pulsing inputs
• Nominal voltage: 220V - 240V • Definable enunciators • EDMI EziView software available for
• Operating range: 176V - 276V • Display available even without main meter programming and reading
power
Calendar
• Withstand: Up to 290V (Windows® compatible)
• Supports Daylight Saving time
• Burden: IEC 62053-61 compliant • EDMI MultiDrive software available for
• Supports Gregorian or Persian calendars
large scale AMI and AMR solutions
Tamper Detection and Alarms (Windows® compatible)
Current
Measured Values • Provision for sealing with conventional • Supported by many popular third-party
• WC range: 5/100A, 10/100A
• 1 element 4 quadrants wire or plastic seals multi-vendor AMR systems
• WC limit: 7000A for 3 cycles
• Import/Export/Absolute Wh, varh and • Reverse current detection • Supports Function Based Setup
• Burden: <0.5VA/phase
VAh • Advanced tamper detection and logging
Frequency • Fundamental Wh • Pre-programmed alarms for meter self-
• 45Hz - 65Hz • W, var, VA, Vrms, Irms check
• Power factor, frequency, phasor angles
Environmental
• Alarms trigger LEDs, enunciators, relay
Relay • Specified operating range:
• Supports ripple control/AFLC outputs or communications event
• 100A IEC 62055-31 Annex C UC3 -25˚C to +60˚C
• Alarms are stored in event logs
• *Relay fault detection Power Quality Indication • Operating range limit:
• Option for fixed-threshold magnetic
• Enhanced relay switching time ≤10s • Total Harmonic Distortion (THD) -40˚C to +70˚C
tamper detection
• May be ordered without a disconnect • Option for live waveform display • Storage range limit:
• *Option for high-sensitivity 3D magnetic
relay
• Sag/Swell tamper detection with configurable -40˚C to +80˚C
- 5 Cycle resolution threshold • Relative humidity:
Inputs/Outputs Configuration
-R
ecords time/date/phase/duration/ Up to 75% mean, 95% non-condensing
• Up to 4 I/O total in 2 isolated groups
average and worst excursion
Security for 30 days
(maximum 1 relay output) • Multi-level security (username and
- Programmable trigger levels • Ingress protection: IP53
• Options include: Passive/Active password including encrypted log-in) • Protective Class II
inputs, S0/Relay outputs Load Survey/Profile • Up to 7 independent security levels • Surge Test: 5kV
• Passive input voltage: 5V, 12V, 48V • Over 5000 days storage (2 channels, • Up to 6 individual users • Impulse Test: 10kV
• Active input voltage: 12V (common 30-minute intervals) • AES128 bit encryption
ground) • Supports Advanced Demand
• S0 output: 27V, 27mA maximum Management (ADM) with prioritised
• Relay output: 240V, 2A rules
• 2 Programmable LED indicators • AMI Ready Communications
• Programmable output pulse width: • Up to 32 channels and 4 independent • Up to 3 independently working
1ms to 100ms surveys communication ports:
• Intervals programmable from 1 to 60 - Optical port: FLAG (IEC 62056-21) or
Battery minutes ANSI Type 2 (ANSI C12.18)
• Internal battery • Energy, instantaneous readings, - RS-232 with modem power supply
• Backup time: 10 years without power pulsing inputs as channel sources (2G/3G/4G/LTE supported)
(Lithium Battery) • Ability to store average/minimum/ - RS-485
multi-drop (2 or 4-wire RJ45 or