Project : Woodlands Avenue

Title : Structural capacity Check on 250 mm Diameter micro pile

I Micropile Capacity For 250mm micropile

A Design Parameters

Proposed System : 3200 KN


Pile diameter : 400 mm
Reinforcement : 4 H 40
Characteristic Strength Rebar ( fy ) 500 N/mm2
28 Days Cube Strength fcu, Cube 40 N/mm2
28 Days Cube Strength fck, Cylinder 32 N/mm2

B Structural Capacity
1 Using EN 1992(EC2)

Action Fc;d= 3200 KN


Resistance Rc;d= (αccfck/ɣm)*Ac + (fs/ɣs)*AS
(0.85fck/1.5)*Ac + (fs/1.15)*AS
4384.75
Over design factor = Rc;d/Fc;d
1.37 > 1.0 OK
ADOPT 4H32 for 250mm MICROPILES
ɣm, ɣs Partial safety factors for resistance
Project : ER381

Title : Structural capacity Check on 300 mm Diameter micro pile

I Micropile Capacity For 300mm micropile

A Design Parameters

Proposed System : 1000 KN


Pile diameter : 300 mm
Reinforcement : 3 H 32
Characteristic Strength Rebar ( fy ) 500 N/mm2
28 Days Cube Strength fcu, Cube 40 N/mm2
28 Days Cube Strength fck, Cylinder 32 N/mm2

B Structural Capacity
1 Using EN 1992(EC2)

Action Fc;d= 1000 KN


Resistance Rc;d= (αccfck/ɣm)*Ac + (fs/ɣs)*AS
(0.85fck/1.5)*Ac + (fs/1.15)*AS
2293.68
Over design factor = Rc;d/Fc;d
2.29 > 1.0 OK
ɣm, ɣs Partial safety factors for resistance
Project : DE120

Title : Structural capacity Check on 350 mm Diameter micro pile

I Micropile Capacity For 350mm micropile

A Design Parameters

Proposed System : 5698 KN


Pile diameter : 400 mm
Reinforcement : 4 H 40
Characteristic Strength Rebar ( fy ) 500 N/mm2
28 Days Cube Strength fcu, Cube 40 N/mm2
28 Days Cube Strength fck, Cylinder 32 N/mm2

B Structural Capacity
1 Using EN 1992(EC2)

Action Fc;d= 5698 KN


Resistance Rc;d= (αccfck/ɣm)*Ac + (fs/ɣs)*AS
(0.85fck/1.5)*Ac + (fs/1.15)*AS
4384.75
Over design factor = Rc;d/Fc;d
0.77 > 1.0 OK
ADOPT 4H40 for 350mm MICROPILES
ɣm, ɣs Partial safety factors for resistance