You are on page 1of 10
[uss Certificate Approval Components and Systems Four ot ne Naor Wagner Alarm- und Sicherungssysteme GmbH SchleswigstraBe 5 DE-30853 Langenhagen ewes wimabniadle fo = G 206004 10 17.02.2006 16.02.2010 ‘mcocunented inte echnical Subject mattor a the Azprova “Siveisyes) Aspirating Smoke Detector cpeigpelceeers Type TITANUS MICRO: SENS® in Automatic Fire Detection Systems Ti certcate mayen be “iined an/eaicate, — CEA 4022 (12/99) - Aspirating Smoke Detectors Senge ote svireg pr EN 54-20 (07/04) - Aspirating Smoke Detectors meres VS 2344 (02/99) - Procedure Guidelines watemens Kélp (Cologne), 28.07.2006 wee ty DAZE 005232 Schiingel iV. Liittepberg VdS Enclosure 1 Sheet 1 To Certificate of Approval No. G 206004 Date 28.07.2006 ‘The approved componentisystem comprises the following parts: ‘Approval number ‘component Description of component Type Applicants Registration No. | (only compet for system approval) Base TITANUS MICRO‘SENS® HB-TM Detection unit TITANUS MICRO-SENS” DM-TM-10 Detection unit TITANUS MICRO-SENS® DM-TM-R-10 Detection unit ‘TITANUS MICRO‘SENS® DM-TM-B-10 Detection unit TITANUS MICRO‘SENS® DM-TM-RB-10 Detection unit TITANUS MICRO‘SENS” DM-TM-Z-10 Detection unit TITANUS MICRO‘SENS” DM-TM-ZB-10 Detection unit ‘TITANUS MICRO-SENS” DM-TM-10-F Detection unit TITANUS MICRO‘SENS” DM-TM-50 Detection unit TITANUS MICRO‘SENS® DM-TM-R-50 Detection unit TITANUS MICRO‘SENS® DM-TM-B-50 Detection unit TITANUS MICRO ‘SENS® DM-TM-RB-50 VdS Enclosure 1 To Certificate of Approval No. G 206004 Date 28.07.2006 ‘The approved componentisystem comprises the following pats: ‘Tpproval number ‘of component Description of component Type ‘Applicant's Registration No. | (only complete for ‘system approval) Detection unit TITANUS MICRO-SENS® DM-TM-Z-50 Detection unit TITANUS MICRO-SENS® DM-TM-ZB-50 Detection unit ‘TITANUS MICRO-SENS® DM-TM-Z-50 Detector box insert ‘TITANUS MICRO‘SENS® DM-MB-TM-10 Detector box insert DM-MB- ‘TITANUS MICRO-SENS” TMB-10 Detector box insert TITANUS MICRO-SENS” DM-MB-TM-50| Detector box insert DM-MB- TITANUS MICRO‘SENS® TM-B-50 Detection unit TITANUS MICRO‘SENS” DM-TM-X-XX-F Detector box insert DM-MB- TITANUS MICRO‘SENS” TM-X-XX-F Parallel indication TITANUS MICRO-SENS” RD-TM Enclosure 2 To Certificate of Approval No. G 206004 Date 28.07.2006 “The approved componeniisystem is described as folows: VdS Sheet 1 ‘Type of document Manufacturer's identification Date Number of Pages VdS Test Report No. BMA 06001, dated 31.01.2006 VAS Software Test Report No. SW-2004248, dated 12.01.2006 Rauchansaugsystem TITANUS MICRO‘SENS” TITANUS MICRO‘SENS® Production documentation CD 1.08 dated 21.11.05: 1, Assembly diagrams, parts lists - lower part complete: list list 2. Assembly diagrams, parts lists — cover complete: Technical Manual 69-30-0520 Lower part complete ~ assembly G631.02, Rev. a Lower part complete — parts list G631.03, Rev. b Air filter - assembly 6639.02 Air filter - parts list 639.03, Rev. a Contact strip long, complete - parts | G632.03, Rev. a Contact strip short, complete - parts | G633.03, Rev. a Cover complete ~ assembly 6634.02, Rev. b Cover complete ~ main parts list 6634.03, Rev. a 05/05 14.03.05 10.03.05 10.03.05 10.03.05 18.02.05 18.02.05 22.02.05 29.12.04 VdS Enclosure 2 Sheet 2 To Certificate of Approval No. G 206004 Date 28.07.2006 ‘The approved componentisystem is described as follows: Number Type of document Manutactucersidentfcaton Date ot Pages 2. Assembly diagrams, parts lists — cover complete: ‘Cover complete — variants parts list G634.03, Rev. b 02.11.05 | 1 Chanal complete ~ assembly G635.02, Rev. f 05.10.05 |1 Chanal complete~main parts list | G635.03, Rev. d 03.11.05 |1 Chanal complete — variants parts list | G635.03, Rev. ¢ 24.08.05 |1 Connection ventilator cable aspirating | G635.04, Rev. a 08.03.05. |1 ventilator / free blasting ventilator Connection ventilator cable aspirating | G635.04 08.03.05. |1 ventilator / redundant ventilator 3. Type labels: ‘Type label WAGNER - chanal G635.07, Rev. b 03.11.05 1 Type label WAGNER - cover G634.07, Rev. ¢ 03.11.05 1 4, Test instructions: Test instructions PA-AD10-DE 26.08.05 2 AD10 - detection unit Test instructions PA-AD10-U_ 26.08.05 2 AD10— lower part complete Test record flir detection unit PP-ADIO-DE 26.08.05 | 1 5. Calibration instructions: Calibration instruction KalanwAD10 07.10.05 2 Configuration calibration progam | SK0048.01, Rev. a o7.11.0s | 1 VdS Enclosure 2 Sheet 3 To Centcate of Approval No. G 206004 Date 28.07.2006 ‘The approved componentisystem is described as folows: Number Type of document Manufacturer's identification Date of Pages 6, Indication board E650: Circuit diagram £650.11 25.05.05 | 1 Component mounting diagram £650.12 25.05.05 1 Parts list £650.13 25.08.05 | 2 7. Main board E647: Circuit diagram, 5647.31, Rev. a 25.05.05 | 1 ‘Component mounting diagram £647.32 25.05.05 | 1 Parts list 647.33, Rev. a 25.05.05 | 2 8. nC board E648: Circuit diagram, sheet 1 648.51, Rev. a 22.08.05 | 1 Circuit diagram, sheet 2 £648.51, Rev. a 22.08.05 | 1 Circuit diagram, sheet 3 £648.51 08.07.05 | 1 Component mounting diagram 648,52 08.07.05 | 2 Parts list 648.53, Rev. a 22.08.05 9. Accessories: Parts list 628.03 25.08.04 1 10. Assignment list: Assignment list: article number~ | £634.10, Rev. a 10.10.05 | 1 hardware - variants VdS Enclosure 2 Sheet 4 To Cericate of Approval No. G 206004 Date 28.07.2006 ‘The approved componantsystom is described as fllows: Number “Typo of document Manufacturers ienticaton Date of Pages ‘TITANUS MICRO-SENS® Mechanics production documentation CD 1.01 dated 22.07.05: 1. Lower part: Lower part, page 1 3 625.11 16.12.04 | 3 Lower part, page 4 625.11 14.12.04 | 1 Lower part, page 5 625.11 16.12.04 | 1 2. Lower part: Lower part 6625.26 20.12.04 | 1 3. Cover: Cover 6625.12 16.12.04 | 5 4, Channel: Channel, page 1-2 6625.13, 08.12.04 | 2 Channel, page 3 6625.13, 16.12.04 | 1 Channel, page 4 6625.13 08.12.04 | 1 Channel, page 5 625.13 09.12.04 | 1 Channel, page 6 6625.13 08.12.04 | 1 Channel, page 7 625.13, 09.12.04 | 1 5. Apertures: Aperture R1 G625.19, Rev. a 21.07.05 | 1 Aperture R2 625.20, Rev. a 21.07.05 | 1 Aperture R3 6625.21, Rev. a 21.07.05 | 1 Aperture T1 G625.22, Rev. a 21.07.05 1 VdS Enclosure 2 Sheet 5 To Centficate of Approval No. G 206004 Date 28.07.2006 ‘The approved componensystem is described as follows: Number Type of document Manufacturer’ identification Date of Pages 6, Channel bottom: Channel bottom G625.14, Rev. a 18.05.05 | 1 7. Contact strip: Contact strip, long G625.16 07.12.04 | 1 Contact strip, short 625.17 07.12.04 | 1 8. Insert: Insert 6625.15 07.12.04 | 1 9. Protective hood: Protective hood 6625.23 17.12.04 | 1 10. Sereening cap: Screening cap 6625.07 07.12.04 | 1 Screening cap — development 6625.07 25.08.04 1 11. Air filter: Filter frame 6625.24 29.11.04 | 1 Filter insert G625.25 29.11.04 1 TITANUS MICRO SENS® ‘Accessories production documentation CD 1.03 dated 07.10.05: 1, Housing and accessories: Housing for accessories — assembly | G637.02 01.04.05 | 2 Housing for accessories ~ parts list | G637.03, Rev. a 29.03.05 | 1 VdS Enclosure 2 Sheet 6 To Certificate of Approval No. G 206004 Date 28.07.2006 ‘The approved componentisystem is described as follows: Number Type of document Manufacturer’ ientfcation Date of Pages 2. Response indicator: Assembly 640.02 04.04.05 | 1 Type label WAGNER G640.07 08.03.05 | 1 Parts list 640.03 04.04.05 | 1 Circuit board E656: Circuit diagram 656.01 28.01.05 | 1 Component mounting diagram 656.02 28.01.05 | 1 Parts list 656,03 01.02.05 1 3. Parallel indicatio Parallel indication - assembly 638.02, Rev. a 04.04.05 | 2 ‘Type label WAGNER for Parallel | G638.07, Rev. a 10.03.05 | 1 indication Parallel indication AD10 — parts list | G638.03, Rev. a 29.03.05 | 1 Circuit board E655: Circuit diagram £655.01 11.11.04 1 Component mounting diagram 655.02 11to4 | 1 Parts list £655.03 WaLo4 | 1 VdS Enclosure 3 Shee To Certificate of Approval No. G 206004 Date 28.07.2006 Instructions forthe application of the approval componenUsystem (see enclosure 1) ‘The following limit values must be observed for adjustment of the airflow monitoring system as a function of the size of the pipework: +/-10% Allowable as a limit value for the threshold of a fault signal are 50% of the total airflow per pipework. This fault shall be detected within 100s, otherwise the application of the aspirating smoke detector shall be restricted to fields of application where conventional point type detectors cannot be used such as in inaccessible areas, where due to the ambient conditions electrically operated fire detectors cannot be installed, or to cases where extra object protection is to be provided in addition to an existing conventional fire detection system used for space monitoring, The projection instructions according to the technical manual 'Rauchansaugsystem TITANUS MICRO SENS ® Stand05/05' of the manufacturer shall be regarded. ‘The function ROOM IDENT® (fire localization) was tested with positive result. It may be realized by the simplified projection described in the technical manual (version 05/05), chapter 4.6.3. When using the ROOM IDENT® function, the minimum distances of the aspirating openings shall be regarded. ‘Technical data: Supply voltage: 15 to30 VDC Starting current (at 24 V): max. 150 mA Uyen=9VDC Uyeni=10,SVDC_—— Uvey=12VDC Uyeai=13,SVDC (at 24. VDC) (at 24 VDC) (at 24 VDC) (at 24 VDC) Current consumption quiescent cond: 10SmA. 125mA, 145mA 170mA Current consumption alarm: Main alarm: 110mA 130mA, 150mA 175mA Main alarm, smoke level: 142mA 160mA, 180mA 205mA Alarm and fault relay: Contact rating: 30 VDC, 1A Switching capacity: max. 24W 1

You might also like