AERZEN STANDARDS ABOUT

PERFORMANCE MEASUREMENT
and for calculation of the standard volume flow.
EXPLANATIONS ON INDIVIDUAL STANDARDS
ABOUT PERFORMANCE MEASUREMENT AND
CALCULATION OF THE STANDARD VOLUME
FLOW.

Packaged unit
performance (W2P) Electric fan (ventilator)
Frequency
converter Motor

M
Belt drive

Blower stage
(with periphery) Rotary pistons - Blower stage
(considered without periphery)

inlet Outlet
Intake side Discharge
losses side losses
1 2

Internal
Internal
users

Mechanical fans
(ventilators)

The power requirement and its characteristics. The following graphic shows the performances relating to blo-
Generally, various performances can be defined depending on wer or compressor packages.
the losses which need to be considered upon definition. The Starting from the lowest power requirement, which means,
more complex a system, a plant or a packaged unit, the more the mechanical shaft performance at the stage, followed by
complex a performance definition or a performance compari- the completely driven packaged unit, the power requirement
son may be displayed. increases or decreases.

• Shaft performance at the stage (unit capacity/ with- • Terminal power Motor
out periphery) Efficiency losses by the motor and mechanical auxilia-
Describes the mechanical performance which is taken ries of the packaged unit are being considered as well
directly at the drive shaft of the stage
• Terminal power Packaged unit
• Coupling power (with periphery) Electrical auxiliaries, which have a separate electrical
Considers in addition to the mechanical performance, connection, are being considered as well
the intake and discharge side losses of the stage’s pe-
riphery • Terminal power Frequency converter
The performance losses caused by a frequency con-
• Drive power required verter are being considered and, consequently, the
Includes in addition the performance losses due to entire drive system
slippage of the belt drive upon power transmission
Explanations for ISO 1217. ASME PTC 10: Acceptable deviations with test parameters for
This international standard, being applied by AERZEN, speci- comparable conditions:
fies methods for a performance measurement, referring to the
volume flow and the power requirement of positive displace- Condition Acceptable deviation in %
ment machines. Inlet pressure 5±
This international standard specifies the operating and test Inlet temperature 8±
conditions which must be taken as basis for a complete perfor- Specific gravitation 2±
mance measurement.
Power 4±
The test runs of compressors with fixed speed, which are pro-
duced in batches or in series and supplied according to specific Input density of the gas 8±
performance values, are described in annexes B, C and D. The
relevance of the respective annex depends on type and design
of the packaged unit. Explanations of ISO 5389
The test runs of compressors with variable speed, which are This standard defines the test conditions for compressor pack-
produced in batches or in series and supplied according to spe- ages which include a centrifugal compressor and are driven by
cific performance values, are described in annex E. an electric motor. It applies to driving power of 75 kW to 1865
In general, the volume flow is defined as per 3.4.1, i.e. as “vol- kW.
ume flow measured at the discharge nozzle and calculated
back to the conditions of the suction side”. Annex C applies
for packaged units with fixed speed for compression of air or The maximum permissible deviations are defined as follows:
nitrogen. According to chart C2, the maximum permissible de-
viations are defined as follows: Volume flow Specific power Power consumption
(according to ISO requirement in % without load
5167 or 9300) in % in %
Volume flow range Useable intake Spec. power
(m3/min) volume flow (%) consumption (%) ±4 ±5 ± 10
< 0.5 ±7 ±8
0.5...1.5 ±6 ±7
1.5...15 ±5 ±6 With more than 150 years of experience as manufacturer of
displacement machines, AERZEN has played a significant role
> 15 ±4 ±5
in creating the ISO 1217. At present, the American standard PTC
13 is in process.
The tolerance values of the a./m. chart include all manufac-
turing and measuring tolerances. As German company, AERZEN carries out its performance
According to annex C.2.4, electrically driven compressors need tests for displacement machines as standard according to
to be measured as completely mounted packaged units (as ISO 1217 as well.
specified by the customer) and evaluated by their terminal Today, the majority of wastewater treatment plants are
power. equipped with frequency converters. In case of retrofitting,
For annex E (compressor with frequency converter) the same we offer our customers low investment costs solutions. Here,
rules and tolerances apply as for compressors with fixed AERZEN as machine supplier, needs to comply with various
speed. frequency converter and motor brands, performance ranges
and efficiencies. Therefore, a power rating with tolerances as
Explanation of ASME PTC 10 - 1997. per ISO 1217 annex E requires that the operator of the waste-
This standard is taken into account in North and South Amer- water treatment plant is being provided with a new blower or
ica. It describes the procedure for determining the thermody- compressor package and a new frequency converter. However,
namic power of axial and centrifugal compressors and fans most plants have already been equipped with a high-quality
(blowers) under specific conditions. frequency converter or it will be purchased in addition.
Aerzener Maschinenfabrik emphasises flexibility. We provide Standards applied in wastewater technology concerning
our customers with project-related and tailor-made solutions. standard volume flow:
AERZEN offers according to customer needs. The calculation of the standard volume flow in the wastewater
technology is subject to different standard validities.
This may include: Overview of the most important standards:
• Individual blower and compressor stages
• Packaged units without motor 1. DIN ISO 1343: volume flow in standard state related to
• Packaged units with motor T1=273 K, p1=1.013 bar, rF=0%
• Packaged units without frequency converter 2. ISO 2533: volume flow in standard state related to
• Packaged units with external frequency converter (for an T1=288 K, p1=1.013 bar, rF=0%
installation in a separate room) 3. ISO 1217: volume flow in standard state related to
• Packaged units with internal frequency converter T1=293 K, p1=1.000 bar, rF=0%

It depends on the scope of supply, which standard or toler- Exemple:


ance is used. For compressor packages which are turbo ma-
chines, the standard ISO 5389 applies in Europe, considering Medium Air
other tolerances. AERZEN is a company which operates on an Intake volume flow Q1 1500 m³/h
international scale with an extensive product portfolio which t1=20°C, p1=1.013 bar, rF=0%
provides various compressor technologies, especially oriented Volume flow in standard state QN 1397 Nm³/h
to the wastewater treatment plant technology. Therefore, related to
T1=273 K, p1=1.013 bar, rF=0%
several standards with different tolerances need to be consid-
Volume flow in standard state QN 1474 Nm³/h
ered. AERZEN makes best use of the standard tolerance in all related to
cases. The standard tolerance gives you and us the certainty T1=288 K, p1=1.013 bar, rF=0%
that every packaged unit, also in combination with an external Volume flow in standard state QN 1519 Nm³/h
brand, guarantees maximum energy efficiency and reliable op- related to
eration. With over more than 150 years of experience as manu- T1=293 K, p1=1.000 bar, rF=0%
facturer of blowers, compressors and turbo machines as well
as pro-found know-how in the field of aeration technology for t1= Inlet temperature
wastewater treatment plants, AERZEN makes a substantial
contribution to respond to the demands of the market.

After consultation, we will calculate for you the power rating


according to your required standard or tolerance. Please
contact us!