SHEET INDEX

SP1− SITE PLAN


S1− FOUNDATION PLAN & DETAILS
A1− FIRST FLOOR PLAN
A2− EXTERIOR ELEVATIONS
A3− ROOF PLAN
E1− FIRST FLOOR ELECTRICAL PLAN

GROSS FLOOR AREAS


FIRST FLOOR: 3,452 O.B.S.F.
TOTAL LIVING: 3,452 O.B.S.F.

GARAGE AND STORAGE: 791 O.B.S.F.


COVERED PORCHES: 788 S.F.
TOTAL UNDER ROOF: 5,031 O.B.S.F.

FIRST FLOOR: 3,331 O.F.S.F.


TOTAL LIVING: 3,331 O.F.S.F.

GARAGE AND STORAGE: 759 O.F.S.F.


COVERED PORCHES: 788 S.F.
TOTAL UNDER ROOF: 4,878 O.F.S.F.

NOTES
1. ALL DIMENSIONS SHALL BE VERIFIED BY CONTRACTOR PRIOR TO CONSTRUCTION
2. VERIFY EXISTING CONDITIONS PRIOR TO CONSTRUCTION
3. SET TOP OF SLAB HEIGHT AS REQUIRED FOR PROPER SITE DRAINAGE.
4. SLOPE ALL GRADES TOWARDS FRONT AND REAR PROPERTY LINES
5. FENCING LOCATION TO BE VERIFIED WITH OWNER
6. FINAL LOCATION OF RESIDENCE, DRIVES, SIDEWALKS, ETC. TO BE VERIFIED WITH OWNER
7. VERIFY WITH OWNER / HVAC CONTRACTOR LOCATION OF A/C CONDENSING UNIT PADS.
8. VERIFY ROOF SLOPES
9. FIREPLACE SIZES TO BE VERIFIED, INCLUDING HEARTH EXTENSIONS VERIFIED BY CODE
10. RIDGE VENTS TO BE INSTALLED AS REQUIRED FOR ATTIC. 1 PER 300 SQ FT.
11. CONTRACTOR IS TO FOLLOW LOCAL AND STATE CODES
12. ALL GLAZING WITHIN 2’−0" OF EXTERIOR DOOR SHALL BE TEMPERED GLASS
13. ALL HVAC, PLUMBING AND ELECTRICAL WORK TO BE PERFORMED BY A LICENSE CONTRACTOR
14. ALL FINISHED PICKED OUT BY OWNER
15. ALL DOOR SIZES TO VERIFIED BY OWNER
16. ALL WINDOW SIZES TO BE VERIFIED BY OWNER
17. ATTIC ACCESS TO BE VERIFIED BY OWNER
18. THIS PLAN IS DESIGNED FOR INTEDED USE OF JAMES HARDE CORNIS PACKAGE. CONTACT
BUILDER/CONTRACTOR FOR VERIFICATION AND APPROVAL. ANY QUESTIONS ON PRODUCT CALL
806.224.5710

CURVE TABLE
CURVE RADIUS ARC LENGTH CH BRG CHORD
C3 240’ 34.30’ N 61 43’ 54" W 34.27’
C4 160’ 6.65’ N 58 49’ 43" W 6.65’

Cisco Residence
Lot 36 Palms at Kitty Hawk
366'-10"

206'-8" 67'-7" 63'-8" 28'-11"

271.36’
10'-0"

10'-0"
C4
27'-6"

27'-6"
INE
EL
NC
FE


.52
171'-0"

171'-0"
96'-9"

96'-9"
15 6
7’
18

Plan Use Agreement

By using these plans builder/owner agrees to the


following. These plans are the property of bh drafting
and design and are not to be traced, reproduced, or
reused for construction without written concent of bh
drafting and design. Builder/ owner shall check and
verify all drawings prior to construction.

Square Footages

FIRST FLOOR: 3,452 O.B.S.F.


TOTAL LIVING: 3,452 O.B.S.F.

GARAGE AND STORAGE: 791 O.B.S.F.


COVERED PORCHES: 788 S.F.
TOTAL UNDER ROOF: 5,031 O.B.S.F.
26'-9"

26'-9"
FIRST FLOOR: 3,331 O.F.S.F.
TOTAL LIVING: 3,331 O.F.S.F.

GARAGE AND STORAGE: 759 O.F.S.F.


COVERED PORCHES: 788 S.F.
TOTAL UNDER ROOF: 4,878 O.F.S.F.

C3
10.21’
10'-0"

10'-0"
Prelim Set #
Project number:

3/32" = 1’−0"
268.30’
20-278

SITE PLAN
206'-8" 67'-7" 92'-7"
Date: Issue:
366'-10" REVIEW
REVISION 1

1
REVISION II
BID
01.07.2021 CONSTRUCTION

Sheet SP1
GENERAL NOTES
1. ALL ELECTRICAL, PLUMBING, & HVAC WORK TO BE PERFORMED
BY A LICENSE CONTRACTOR.
2. CONCRETE TO BE 3000 PSI W/#3 @ 16" O.C.E.W. OR FIBERMESH.
3. GARAGE FLOOR TO BE POURED SEPARATELY AND SLOPE 1/4"
PER 1’−0" AWAY FROM RESIDENT.
4. FLATWORK TO SLOPE 1/4" PER 1’−0" AWAY FROM RESIDENT.
5. ALL SHOWER FLOORS TO BE RECESSED 3−1/2" INCHES. UNLESS OTHERWISE NOTED

FOUNDATION NOTES
1. ALL CONCRETE IS 3,000 PSI W/ POLYPROPYLENE FIBERMESH.
2. POLYPROPYLENE FIBERMESH CAN NOT REPLACE REBAR.
3. ADD 5%−6% AIR ENTRAINMENT TO EXTERIOR CONCRETE.
4. REBAR LARGER THAN #3 GRADE 60.
5. COMPACT SUBGRADE: 95% MIN STD PROCTOR.
6. 4" TYPICAL SLAB THICKNESS (NOT 3 1/2").

95'-11"

3'-3" 15'-8" 18'-0" 18'-8" 40'-4"

14'-10" 3'-10" 15'-6" 12'-6" 12'-4"

Cisco Residence
1'-6" 7'-5" 1'-6" 7'-4 1/2" 1'-6"

1'-6"
1'-6"

Lot 36 Palms at Kitty Hawk


5'-6"

2'-10"

11'-4"
11'-10"
9'-2"

16'-1"
16'-0"
16'-2"

4'-11"
4'-3"

28'-9"
18'-4"

INTERIOR LOAD BEARING WALL

9'-8"
CONCRETE SLAB−ON−GRADE PER CITY OF LUBBOCK
REQUIREMENTS

14'-10" 1'-0" 6'-4" 12'-0" 12'-4" 12'-6"


1’ − 4"

(MIN.) #3 TIES AT 32" O.C.

2" CLR.
11'-9"

11'-9"

1’ − 0"

(MIN.)
12'-6"
2'-2"

2−#4 BARS CONT. SET ON COMPACTED FILL


REBAR CHAIRS
6'-9"

6 MIL VAPOR RETARDER, OVERLAP 6" AND TAPE PER


MFR. RECOMMENDATION
UNFORMED CONTINUOUS
FOOTING

3" CLR.

1’ − 4"

CONTINUOUS FOOTING FOR INTERIOR LOAD


(MIN.)

BEARING WALL
12'-1"

1
1/2" = 1’−0"

5'-9"
13'-2" 3'-8" 3'-5"
5'-10"

4'-10"
20'-3"
66'-9"

66'-9"
13'-11"
4'-0"
2'-2"

5 1/2"

8'-2"

8'-3"
CHAMFER OR TOOLED EDGE

STUD LINE
2'-10"

EXPANSION JOINT FILLER MATERIAL WITH CAULKING


2"

#3 BAR
10'-8"

CONT.
#3 U−SHAPED DOWELS AT 32" O.C.

VARIES
8'-6"

SLOPE

2’ − 0" (MIN.)

1’ − 0" (MIN.)
33'-2"
7'-4"

7'-4"
COMPACTED FILL
9'-0"
11'-8"

4−#4 BARS EACH WAY

3" CLR.
1’ − 4" (MIN.)

28'-4"
2’ − 6" (x VARIES) CONTINUOUS FOOTING BEYOND (REINFORCING
CONTINUOUS THROUGH SPREAD FOOTING)

TWO−POUR SPOT FOOTING AT GARAGE DOOR


6'-0"

OPENING
1'-8"

2
1/2" = 1’−0"
Plan Use Agreement

18'-4"
By using these plans builder/owner agrees to the
1'-10"

following. These plans are the property of bh drafting


and design and are not to be traced, reproduced, or
reused for construction without written concent of bh
drafting and design. Builder/ owner shall check and
verify all drawings prior to construction.
8'-4"
6'-6"

6'-6"

Square Footages
17'-8"
17'-8"

FACE BRICK WITH BRICK TIES AT 24" O.C. MAX. 5 1/2"


EACH WAY (BRICK TIES TO SUPPORT NO MORE
THAN 26.7 SQUARE FEET OF BRICK AREA)
14'-2"

FIRST FLOOR: 3,452 O.B.S.F.


TOTAL LIVING: 3,452 O.B.S.F.
2'-4"

STUD LINE
GARAGE AND STORAGE: 791 O.B.S.F.

1'-9"
4'-4"

4'-4"

BUILDING WRAP COVERED PORCHES: 788 S.F.


INSULATION
TOTAL UNDER ROOF: 5,031 O.B.S.F.
THRU WALL FLASHING FIRST FLOOR: 3,331 O.F.S.F.
TOTAL LIVING: 3,331 O.F.S.F.
MORTAR NET
GARAGE AND STORAGE: 759 O.F.S.F.
WEEPHOLES AT 33" O.C. MAX
COVERED PORCHES: 788 S.F.
2'-4" 10'-5 1/2" 2'-4" 6'-10 1/2" 2'-4" 18'-9"

4'-10"
LAP SHEATHING OVER JOINT
TOTAL UNDER ROOF: 4,878 O.F.S.F.

FILL CAVITY WITH GROUT CONCRETE SLAB−ON−GRADE PER CITY OF LUBBOCK REQUIREMENTS

2" CLR.
2’ − 0" (MIN.)
COMPACTED FILL

Prelim Set #

1’ − 0"

(MIN.)
6 MIL VAPOR RETARDER
9'-4" 9'-3"

3" CLR.
2−#4 BARS CONT. TOP AND BOTTOM (LAP 18" AT
SPLICES)

1'-6" 15'-2" 13'-2" 18'-7" 10'-6" 14'-6" 10'-2" 12'-4" UNFORMED CONTINUOUS FOOTING 7 1/2"
Project number:
(MIN.) #3 TIES AT 24" O.C.
3" CLR.
20-278
95'-11" 1’ − 4" 8"

TYP. TWO−POUR COMBINATION EXTERIOR


(MIN.) (MIN.)
Date: Issue:
FOUNDATION PLAN FOOTING
4 3 REVIEW
1/4" = 1’−0" 1/2" = 1’−0" REVISION 1
REVISION II
BID
01.07.2021 CONSTRUCTION

Sheet S1
GENERAL NOTES
1. ALL ELECTRICAL, PLUMBING & HVAC WORK TO BE PERFORMED BY A LICENSED CONTRACTOR.
2. ALL FINISHES SELECTED BY OWNER.
3. VERIFY ALL DOOR HEIGHTS.
4. VERIFY ALL WINDOW SIZES.
5. VERIFY ATTIC STAIR LOCATION. INSTALL PER MANUFACTURERS INSTRUCTIONS.

HEADER SCHEDULE
SPAN SIZE

4’−0" TO 4’−11" 2− 2x6’S


5’−0" TO 6’6" 2− 2x8’S
6’−7" TO 8’−3" 2− 2x10’S
8’−4" TO 10’−0" 2− 2x12’S

NOTES:

1. ALL HEADERS SPANNING 10’−0" OR GREATER NEED AN ENGINEERED BEAM.


2. ALL HEADERS AT FIRST FLOOR OF TWO STORY HOUSE TO BE 2− 2x12’S WHEN THERE IS A FLOOR ABOVE,
UNLESS OTHERWISE NOTED.
3. USE O.S.B. BLOCKS AS HEADER FILLERS UNLESS LOCAL CODE REQUIRES CONTINUOUS O.S.B. FILLER.

WALL BRACING

AS INDICATED BY:

A. BRACED WALL PANEL FOR ONE STORY AND TWO STORY


APPLICATIONS. MINIMUM 4’−0"
B.ALTERNATE BRACED WALL PANEL FOR ONE STORY
APPLICATIONS. 2’−8" TO 4’−0"
C. SIMPSON STRONGWALL 18", 24", 32"
D. FIELD− FABRICATED PORTAL FRAME SYSTEM

95'-11"

3'-3" 15'-8" 18'-0" 18'-8" 40'-4"

8'-3" 7'-5" 14'-8" 4'-0" 15'-4" 12'-6" 3'-5" 5'-4" 3'-9"

7'-6" 7'-2" 2'-6" 10'-9" 2'-1" 2'-5" 7'-10" 2'-3"

Cisco Residence
A B A
B A
3060 3060 3060 3060

SILL @ 2’−0" SILL @ 2’−0" SILL @ 2’−0" LINEN


LVL LVL LVL SILL @ 2’−0"
LINEN TUB & SHOWER

2'-9"
8'-11" 8'-10 1/2"
5'-6"

LVL A 2880

6'-6"
3'-7"

Lot 36 Palms at Kitty Hawk


3'-9"
A B
15'-4" 4'-2" 8'-4" 6'-1" 6'-5"
TRIPLE 2860

2480
11'-10"
A

12' - 7"
SILL @ 2’−0" GAME ROOM BEDROOM NO. 2

9'-11"
10’ CLG. 10’ CLG.
3'-9"

2480
16'-3"
15’−0" X 15’−0" 12’−2" X 12’−0"
SILL @ 6’−0"

4'-10"
REAR PATIO

5'-0"
2020

10’ CLG.

SILL @ 4’−0"
B 2480
17’−0" X 19’−6" A

2040
A TRIPLE 2860

9'-9"
4'-5"

2680 BARN
SILL @ 2’−0" CLOSET 2480
MASTER BEDROOM CLOSET
SILL @ 6’−0"

9’ CLG.
16'-0"
2020
16'-4"

2680

4'-11"
10’ CLG. 9’ CLG.

4'-9"
4'-4"

4'-5"
7’−10"X4’−6"

28'-9"
3' - 8"
2880
18'-4"

15’−0" X 15’−8" 7’−6" X 3’−5"

2480
2080 BARN 2080 BARN

SILL @ 2’−0"
TWIN 3060
DINING A
4'-5"

10’ CLG.

9'-8"

2'-2"
14’−4" X 11’−4"
SILL @ 6’−0"

SILL @ 2’−0"
2020

9'-11" 5'-9" 2880

4080 C.O.

3060
5'-2"
5'-4"

5'-2"
5'-2"
13'-8" 2'-0" 6'-4" 9'-8" 2'-4" 9'-9" 2'-7" 12'-8"
3'-9"

3080

3080 BARN BEDROOM NO. 3


2680 PCKT. E SPACE / DESK 10’ CLG.

7'-11"
2880

12'-6"
(4) 3080 SLIDER

2'-0"
B
MASTER BATH 12’−0" X 12’−0"

2'-5"

LINEN
2'-0"

2'-4"

LINEN
3080 C.O.

B 10. CLG.
4'-9"

A
12’−7" X 16’−9"

6'-10"
1'-9"

OVEN /
3'-3" 2'-4 1/2" CLOSET
SILL @ 6’−0"

7'-4"
2020

MICRO

SILL @ 2’−0"
3'-0"

LINEN

4'-7"
9’ CLG.

3060
6'-5"

2680
RAIN BUILT IN 9’−4" X 4’−3" BEDROOM NO. 4
2'-0"

2'-5"
HEAD 10’ CLG.
LIVING ROOM 2480 PCKT. 12’−0" X 12"−0" NOTE:

D.W.
9"
5'-6"

2680
A 2480 CATHEDRAL 3'-4" 8'-8" 4'-0" 8'-8" B
12'-1"

ALL STRUCTURAL FRAMING AND FOUNDATION SHALL


8'-7"

3'-10" 7'-2" 2'-0" 3'-8" 3'-2" A

2'-7"
VERIFY FIREPLACE SIZE BE SIZED ACCORDING TO LOCAL BUILDING CODES
20’−0" X 18’−11" B

SILL @ 2’−0"
MUDROOM
3'-7"

4'-2"

5'-0"
3060
5'-9"
10’ CLG.
TRENCH
14'-9"

2'-5"
LINEN
DRAIN 6’−0" X 11’−4"
6"
SILL @ 6’−0"
66'-9"

66'-9"
LINEN ROOFING MATERIAL SELECTED BY

TRASH
OWNER OVER 15# FELT OVER 1/2"
2020

3'-3"

OSB DECK 2x6 RAFTERS @16" O.C.

13'-8"
1'-6" 2'-9" 3080
1'-9"

6'-5"

3'-10"
HIDDEN UP TO ATTIC
KITCHEN
4'-7"

STORAGE
12
10’ CLG.

3080 C.O.
LOCKERS UNDER STAIRS
2'-4"

2'-4"

LINEN REFER TO
ELEVATIONS
B 2680 PCKT. 14’−4" X 15’−11"

8'-3"
HURRICANE TIES
@ EACH RAFTER
A
1680

1680

1’ − 5"
2'-10"

4'-0"
3'-3"

3080 BARN REF. 3080


3080 PCKT.
10'-8"

5 1/2"
MASTER CLOSET
8'-4"

2680
10’ CLG.
2680

HIDDEN DOOR ICE.


UTILITY
D
3080 BARN

15’−0" X 8’−0" 2680


11’ CLG.
4'-11"

2' - 3" 6' - 10"


10’−6" X 6’−10"

33'-2"
7'-6"
7'-2"

STUDY FOYER
1/2X FASCIA
W
SHELVES

& DRIP EDGE

CATHEDRAL 10’ CLG.


11'-6"

12’−6" X 11’−2" 9’−2" X 9’−8" PANTRY

28'-2"
A
3'-11"

SOFFIT VENT
REF. 10’ CLG. SILL @ 4’−0"

18’−0" X 8’−0" O.H. DOOR


GYP CEILING
6’−6" X 8’−6"
6'-0"
6'-0"

3080

2−CAR GARAGE
1'-8"

A SILL @ 0’−0" SILL @ 0’−0" SILL @ 2’−0" 2040 A


A
10’ CLG.

18'-0"
1'-10"

B
SILL @ 2’−0" 2080 2080
B
3060 B 24’−0" X 24’−0" Plan Use Agreement

By using these plans builder/owner agrees to the


following. These plans are the property of bh drafting
TWIN 3060 and design and are not to be traced, reproduced, or
FRONT PORCH reused for construction without written concent of bh
drafting and design. Builder/ owner shall check and
LVL 10’ CLG.
verify all drawings prior to construction.
12'-10"
12'-10"
6'-11"

6'-11"

22’−0" X 8’−0"
1'-6" 11'-3 1/2" 1'-6" 7'-8 1/2" 1'-6"
17'-8"

CATHEDRAL LVL A MASONRY VENEER W/ BRICK


Square Footages
TIES @ 16" O.C.E.W. OVER
14'-2"

AIR GAP OVER


MOISTURE BARRIER
1'-6"

6" 1'-6"

2880

OVER 1/2" GYP SHEATHING

1'-11"
SILL @ 2’−0" FIRST FLOOR: 3,452 O.B.S.F.
LVL LVL D TOTAL LIVING: 3,452 O.B.S.F.
1'-6"

GARAGE AND STORAGE: 791 O.B.S.F.


TWIN 3060 COVERED PORCHES: 788 S.F.
WH STORAGE B B TOTAL UNDER ROOF: 5,031 O.B.S.F.
LVL CONT THRU
4'-10"

4'-10"
FIRST FLOOR: 3,331 O.F.S.F.
10’ CLG. WALL FLASHING TOTAL LIVING: 3,331 O.F.S.F.
4'-10"

W/ WEEP HOLES &


13’−10" X 4’−8" A
WICKS @ 48" O.C. GARAGE AND STORAGE:
COVERED PORCHES:
759 O.F.S.F.
788 S.F.
TOTAL UNDER ROOF: 4,878 O.F.S.F.
SILL @ 6’−0" SILL @ 6’−0" SILL @ 6’−0"
FINISHES AS
SCHED.
2020 2020 2020
B B
5'-2" 4'-3" B 100'-0"
B
F.F.

8"
6'-7" 6'-7" 9'-2" 9'-5" 5'-3" 5'-3" 3'-4" 3'-11" 3'-11" 3'-4" 5'-2" 5'-0"
5"

Prelim Set #
EXP. JT.
1'-6" 15'-2" 13'-2" 18'-7" 10'-6" 14'-6" 10'-2" 12'-4"
REFER TO FOUNDATION PLAN

95'-11"
Project number:
20-278
F.F. WALL SECTION
2 1 Date: Issue:
1/4" = 1’−0" 1/2" = 1’−0"
REVIEW
REVISION 1
REVISION II
BID
01.07.2021 CONSTRUCTION

Sheet A1
12

8:12
8:12
8:12
12
17’−6" PLATE

8:12
30 YEAR ROOF, SELECTED BY OWNER
8
117’ − 6"

8:12
12
2030 2030
8

8:12
11’ PLATE
111’ − 0"
10’ PLATE 10’ PLATE
110’ − 0" 110’ − 0"

BRICK, SELECTED BY OWNER

STUCCO, SELECTED BY OWNER

STONE, SELECTED BY OWNER

F.F. F.F.
100’ − 0" 100’ − 0"

FRONT
1
1/4" = 1’−0"

12

8:12

8:12
12

8:12
8

8:12
30 YEAR ROOF, SELECTED BY OWNER

8:12
8:12
4:12

4:12
10’ PLATE 10’ PLATE

Cisco Residence
110’ − 0" 110’ − 0"

BRICK, SELECTED BY OWNER

Lot 36 Palms at Kitty Hawk


F.F. F.F.
100’ − 0" 100’ − 0"

BACK
2
1/4" = 1’−0"

12

8:12
12 STUCCO, SELECTED BY OWNER

8:12
8

8:12
8:12

8:12
8:12

8:12

8:12
30 YEAR ROOF, SELECTED BY OWNER

8:12

8:12
10’ PLATE 10’ PLATE
110’ − 0" 110’ − 0"

BRICK, SELECTED BY OWNER

STONE, SELECTED BY OWNER

F.F. F.F.
100’ − 0" 100’ − 0"

LEFT
3
1/4" = 1’−0"

12

8:12
12

8:12
Plan Use Agreement

By using these plans builder/owner agrees to the


following. These plans are the property of bh drafting
8:12

and design and are not to be traced, reproduced, or


reused for construction without written concent of bh
drafting and design. Builder/ owner shall check and
verify all drawings prior to construction.

30 YEAR ROOF, SELECTED BY OWNER


8:12

Square Footages

10’ PLATE 10’ PLATE


110’ − 0" 110’ − 0" FIRST FLOOR:
TOTAL LIVING:
3,452 O.B.S.F.
3,452 O.B.S.F.

GARAGE AND STORAGE: 791 O.B.S.F.


COVERED PORCHES: 788 S.F.
TOTAL UNDER ROOF: 5,031 O.B.S.F.

FIRST FLOOR: 3,331 O.F.S.F.


TOTAL LIVING: 3,331 O.F.S.F.
BRICK, SELECTED BY OWNER
GARAGE AND STORAGE: 759 O.F.S.F.
COVERED PORCHES: 788 S.F.
TOTAL UNDER ROOF: 4,878 O.F.S.F.

STONE, SELECTED BY OWNER

F.F. F.F.
100’ − 0" 100’ − 0"
Prelim Set #
STUCCO, SELECTED BY OWNER
Project number:
RIGHT 20-278
4
1/4" = 1’−0"
Date: Issue:
REVIEW
REVISION 1
REVISION II
BID
01.07.2021 CONSTRUCTION

Sheet A2
Cisco Residence
Lot 36 Palms at Kitty Hawk
10’

10’
10’

10’
10’

8:12

8:12
10’

4:12
8:12

4:12
4:12
8:12 8:12

10’
8:12
8:12

8:12
10’

8:12
8:12

8:12
8:12
8:12
10’

8:12 8:12 10’ 10’

8:12
8:12

8:12

8:12
8:12

10’
10’
8:12
10’

Plan Use Agreement

8:12 8:12 8:12 8:12 By using these plans builder/owner agrees to the
following. These plans are the property of bh drafting
and design and are not to be traced, reproduced, or
reused for construction without written concent of bh
drafting and design. Builder/ owner shall check and
verify all drawings prior to construction.

10’ 10’
Square Footages

8:12 8:12 11’


8:12 8:12
10’ FIRST FLOOR:
TOTAL LIVING:
3,452 O.B.S.F.
3,452 O.B.S.F.

GARAGE AND STORAGE: 791 O.B.S.F.


COVERED PORCHES: 788 S.F.
TOTAL UNDER ROOF:
10’

5,031 O.B.S.F.

FIRST FLOOR: 3,331 O.F.S.F.


TOTAL LIVING: 3,331 O.F.S.F.

GARAGE AND STORAGE: 759 O.F.S.F.


COVERED PORCHES:

10’
788 S.F.
10’

TOTAL UNDER ROOF: 4,878 O.F.S.F.

10’
8:12 8:12
10’

Prelim Set #
Project number:
8:12 8:12 20-278

10’
Date: Issue:
REVIEW

ROOF PLAN REVISION 1


1
1/4" = 1’−0" REVISION II
BID
01.07.2021 CONSTRUCTION

Sheet A3
GENERAL NOTES
1. ALL ELECTRICAL WORK TO BE PERFORMED BY A LICENSED ELECTRICAL CONTRACTOR
2. VERIFY SWITCHING & COMM LAYOUT WITH OWNER
3. VERIFY ALL POWER REQUIREMENTS FOR APPLIANCES, WATER HEATERS, HVAC UNITS, ELECTRIC FIREPLACE, ETC
4. PROVIDE AND INSTALL ATTIC LIGHTING AND POWER PER OWNER
5. ALL EXTERIOR OUTLETS TO BE WEATHER−PROOF
6. VERIFY ALL CABLE AND TELEPHONE JACKS WITH OWNER
7. ELECTRICAL LAYOUT IS SCHEMATIC ONLY, VERIFY ALL LOCATIONS WITH BUILDER/OWNER

ELECTRICAL LEGEND
3 3−WAY LIGHT SWITCH

SPST LIGHT SWITCH

110V DUPLEX RECEPTACLE OR 220V RECEPTACLE


GFI
DUPLEX RECEPTACLE WITH GROUND FAULT PROTECTION

48" (4 LAMP) SURFACE MOUNTED FLUORESCENT LIGHT

RECESSED INCANDESCENT CAN LIGHT


(OPTION: SURFACE MOUNTED IN CLOSETS)

RECESSED DIRECTIONAL INCANDESCENT LIGHT

PENDANT MOUNTED INCANDESCENT LIGHT

CEILING FAN WITH LIGHT KIT

CEILING FAN WITHOUT LIGHT KIT

HVL HEATER/ EXHAUST VENT/ LIGHT

INCANDESCENT WALL MOUNTED VANITY LIGHTS

DATA OUTLET ( LAN OR COAX− VERIFY WITH OWNER)

TELEPHONE

TRACK LIGHT

EAVE MOUNTED EXTERIOR FLOOD LIGHT

INTERIOR WALL SCONCE

EXTERIOR WALL SCONCE

S SMOKE− CARBON DIOXIDE DETECTOR

HEATER 200 POWER

Cisco Residence
XMAS
VL
XMAS

Lot 36 Palms at Kitty Hawk


GFI GFI

GFI
S
S

S C
S

S
GFI

3
GFI
S C S

VL

220
GFI
VL

GFI

GFI
VL

VL

220
GFI

GFI
GFI
GFI TO ABOVE

42"

S C

GFI GFI GFI


GFI

220

GFI
XMAS

GFI

GFI
24"
GFI GFI
GFI

42"
24" 24"

24"

GFI GFI

Plan Use Agreement

By using these plans builder/owner agrees to the


following. These plans are the property of bh drafting
and design and are not to be traced, reproduced, or
reused for construction without written concent of bh
drafting and design. Builder/ owner shall check and
verify all drawings prior to construction.

Square Footages

TIMER
24"
GFI

FIRST FLOOR: 3,452 O.B.S.F.


TOTAL LIVING: 3,452 O.B.S.F.

XMAS
GARAGE AND STORAGE: 791 O.B.S.F.
COVERED PORCHES: 788 S.F.
TOTAL UNDER ROOF: 5,031 O.B.S.F.

FIRST FLOOR: 3,331 O.F.S.F.


TOTAL LIVING: 3,331 O.F.S.F.

24" 24" GARAGE AND STORAGE: 759 O.F.S.F.


COVERED PORCHES: 788 S.F.
TOTAL UNDER ROOF: 4,878 O.F.S.F.

ELECTRICAL PLAN
1
1/4" = 1’−0"

Prelim Set #
Project number:
20-278

Date: Issue:
REVIEW
REVISION 1
REVISION II
BID
01.07.2021 CONSTRUCTION

Sheet E1