Professional Documents
Culture Documents
Webinar Wincc Scada NL 29052018
Webinar Wincc Scada NL 29052018
4 SP1
WinCC V15 Professional
The scalable, open SCADA systems for maximum plant
transparency and productivity
Page 1 May 2018 siemens.com/wincc
SIMATIC HMI vs SCADA
The entire world of human machine interfacing & positioning
Enterprise Resource Planning (ERP)
Manufacturing Execution Systems (MES)
Internet /
Intranet
Single-user PC Client/Server Web Client WinCC Options
Process visualization with Plant Intelligence: SIMATIC WinCC V 7.4 SP1 & V15 Prof
ƒ Scalable from single-user up to distributed multi-user systems
with redundant servers and Web clients
ƒ Open standards for easy integration
(incl. integrated MS SQL Server 2014 database)
ƒ Expandable through options and add-ons
Unrestricted © Siemens AG 2018
Page 3
What’s available or new in the
Basic SCADA System ?
in SIMATIC WinCC V7.4 SP1
in TIA Portal V15 – WinCC RT Professional
in SIMATIC WinCC V7.4 SP1 and in V15 RT
Professional
SIMATIC WinCC V7.4 SP1
Operating Systems
Supported Operating Systems
ƒ Windows 7 SP1 32bit & 64bit (Professional / Enterprise / Ultimate)
ƒ Windows 8.1 32bit & 64bit *(Professional / Enterprise)
ƒ Windows 10 64bit *(Professional / Enterprise)
ƒ Windows 10 64bit LTSB
For installation under Windows Server 2016, SIMATIC Net V14 SP1 is required
*only approved for integrated operation in SIMATIC Manager (Engineering Station) when using Step 5.6
New in V7.4 SP1
Unrestricted © Siemens AG 2018
Page 5
TIA Portal V15 – WinCC RT Professional
Installation info & 2 New SUS contracts for RT Prof
SIMATIC S7 Protocol Suite Allen Bradley E/IP Mitsubishi Ethernet Modbus TCP/IP S7-1200 S7-1500 OPC UA client & server
S5 channels =
only in WinCC V7
not in TIA !!!
• Chronological reporting (program alarm) Load the AS Symbols (tags and alarms)
⋅Support of full text alarms like RT Prof V14 Offline import of configuration data from TIA Portal
• Support S7-1500 with WinCC Server-Client-System Setup Pre- / Suffix as default value for tags
• Step-up of the connection system limits to 128 for the communication to a S7-1500 PLC
• Offline Import from TIA Portal V13 SP1 onwards • Import in WinCC via„Load from File“ Dialog
• Tool directly Integrates in TIA Portal menu • Grid View for Navigation through the PLC
• Export to a .zip-File
• Short time-to-market
• Less errors through tested standards
3. Result in RT
Benefit
• 2 Finger Zoom
to zoom picture contents,
to show and hide layers
using decluttering function
• Panning
zoomed picture content
• Wipe / Flicks
picture changes through „wiping“ over the monitor
• 2-hand handling
enable operation or setpoint changes
Data management
Consistent data
throughout the entire
production
• Complete transparency
Trend indicator and notification – anytime, anyplace
Reference curves
(comparison of curves e.g. „Golden Curve“)
Central administration of texts in all languages Clear administration of texts for all target countries
export/import
Compliance Responses ERES (Electronic Records / Electronic Signatures) for Siemens products :
GMP-conformity in pharmaceutical industry
How do you generate user-defined operator input messages in WinCC?
https://support.industry.siemens.com/cs/ww/en/view/24325381
Record operator actions in WinCC Professional with the WinCC WebNavigator
https://support.industry.siemens.com/cs/be/nl/view/109479441/en
Unrestricted © Siemens AG 2018
Page 28
SIMATIC WinCC V7.4 SP1 / V15 RT Professional
Consistent protection according to IT guidelines
SIMATIC Logon
OK Cancel
Integration to windows user administration Support of domain concepts and windows workgroups
(consistant from SIMATIC panels to WinCC
Runtime stations)
Example of Benefit
Virtual WinCC Clients on Hypervisor
Audit
Telecontrol * Process Historian
Change Control
SES *
Plant Intelligence
Increased Availability Energy Management
ConnectivityPack / Station
Energy Manager Pro
Redundancy IndustrialDataBridge
ProAgent * DataMonitor
Information Server
www.siemens.com/simatic-wincc-options * No tested and released for V7.4 SP1 yet
PerformanceMonitor
Only use (and buy) the functionality which is necessary for your industry
Unrestricted © Siemens AG 2018
Page 32
.
TIA Portal V15 – WinCC RT Professional
Options for WinCC V15 (grey = not available)
• Performant archiving
… of coherent recipes and parameter sets
• Efficient administration
… administration of recipes / parameter sets directly
through HMI
WinCC RT Clients
WinCC Redundancy
WinCC WinCC WinCC
WinCC Client/Server
Max 1..32 UNI-Clients
• Multi-user system of up to 32 client stations
WinCC RT Clients
… … • WinCC Basic
e.g. WinCC V7.4 RT 64K
•ƒ •ƒ •ƒ ‚ WinCC RT Client
•ƒ MLFB: 6AV6381-2CA07-4AX0
…
Max 1
(redundant pair) of ƒ WinCC/Server
WinCC Servers MLFB 6AV6371-1CA07-4AX0
WinCC WebUX
• Secure information
thanks to Web-Standards (access through HTTPS, SSL
certificate) with consistent user administration
• „Ready to use“
thanks to various maintenance free Clients
VB Scripts
- Global
- At properties
- At events
C Scripts
Scheduled tasks
Faceplates /
Customized Objects
Graphic format: BMP, TIF , PNG , ICO , EMF, WMF , GIF , JPG , JPEG , SVG
Online status display of used WebUX licenses and automatic Login for Monitor Only WebUX clients
Unrestricted © Siemens AG 2018
Page 41
SIMATIC WinCC V7.4 SP1 / V15 RT Professional
Licenses for WebNavigator and WebUX
Office PC
Web Browser Microsoft Office
Office PC
Scalability of Reports
(Excel, Word)
Web Browser Microsoft Office
(Excel)
WinCC DataMonitor
WinCC
Reports
SIMATIC
Process Historian
WinCC
Single station
or WinCC Server Tags,Alarms
OS server
WinCC/ConnectivityStation
Tags,Alarms
WinCC/ConnectivityPack
Scalability
of Archives
Unrestricted © Siemens AG 2018
Page 43
SIMATIC WinCC V7.4 SP1 / V15 RT Professional
Comprehensive archiving as interface to the IT- and MES/ERP world
• Efficient archiving
long-term and real time with minimal memory
requirement – can optionally be redundant
Information
management
Transparent
production for
optimized ...making the
processes right decisions
Web-based reporting instantly
… target group-specific analysis of production data
with the SIMATIC Information Server
• Complete transparency
thanks to consistent analysis of
data from various sources
„Interlocking“
… has an action
been executed and has „Action“
enable been given? … for example, has a product left
the initial position after the
start command?
• "independent"
... of language editors / program code
DB FB
PLC Data Function
Tag Table block block
• "comprehensive"
… also for safety and know-protected blocks
• "consistent"
... Integration in cross-reference functions with
permanent data consistency
Energy
management
Energy transparency
for energy savings
according to ...energy-efficient
ISO 50001 production in
compliance with
Easy and efficient recording of energy data legal stipulations
… as integrated automation solution with the
SIMATIC Energy Suite
Plant operator
Efficient and economic
energy consumption
management across
site boundaries
Targets
Live consumption
display and monitoring
via panel and SCADA
Costs Laws Image
Consumption
detection
integrated in
automation
Energy transparency
Benefit
ƒ S7 Energy Efficiency-
Monitor for Machines
V15 , S7-Instruction for analysis
energy efficiency of
Visualization & Archiving Energy Efficiency machines (according to
of Machines VDMA 34179)
Planned (according VDMA 34179) , Screen and report
V14 V16 templates will be provided
A by application examples in
Energy Data Load B the Online Support
C
Acquisition Management ƒ General Improvement:
No PowerTag license
count anymore*
⇓Only Energy Objects must
be licensed
Machine
* in WinCC Professional
Unrestricted © Siemens AG 2018
Page 57
TIA Portal V15 – WinCC RT Professional
Energy Suite integration
Function
Visualization of energy data
in energy objects requires no
additional PowerTags in
WinCC Professional
Customer benefits
• Cost reduction
Number of PowerTags is not
increased by energy data
Comparison
• Simplified order process
• Number of PowerTags required does V14 From V15
not have to be calculated in advance Number of PowerTags per energy
object Up to 180 0
• New measuring points do not lead
in parallel to the PowerTag license
being exceeded
HMI
SCADA
(machine level)
WinCC V7.4 SP1
The standard
WinCC SCADA System
Professional
V15
WinCC Advanced the SCADA
(TIA Portal) System in
WinCC Comfort for PC-based TIA Portal
(TIA Portal) single-user solutions
for Panel-based
solutions
Arlette Sente
Sales Specialist Scada Systems
Phone: +32 477 275 062
E-Mail: arlette.sente@siemens.com
The scalable, open SCADA systems for maximum plant transparency and productivity
Page 62 May 2018 © Siemens AG 2018. All Rights Reserved. siemens.com/wincc
Page 63 May 2018 © Siemens AG 2018. All Rights Reserved. siemens.com/wincc