Specification No.

: KP046-SS005-MS-05/357 (Annexure-C1 & C1) & DPP004-SS005-MS-01/357

Sr. Test Required to verify Parameters to be tested Test Equipment Required and
No. ordered specifications their source
1. Chemical Analysis Chemical composition XRF Analyzer/Spectroscopy or any
other suitable technique
2. Physical properties/ Analysis i. Dimensions/size as per ordered i. Measuring Tape
specifications ii. Vernier Caliper
ii. Quantity as per supply order iii. Weighting scale
iii. Weight as per supply order iv. Block Bubble Level Scale
iv. Plates should be new, straight,
dent free & free from defects having
workman like finish
v. Plates should be furnished with
plain ends. All burr at the ends of the
plate should be removed
vi. Heat Number, Material Grade, Size
of plate & manufacturers/logo should
be present on the plates and Heat
Numbers must match with relevant
MTCs
3. Mechanical Analysis/ Test Tensile Strength, Yield Strength, Universal Testing Machine and any
% Elongation in 2in.(min) , other suitable accepted methods/
% Reduction in Area(min), Hardness techniques
Brinell, Hardness Rockwell C and
Impact according to ASTM A-370/
E8 / E8M standard
4. Material Test Certificate (MTC)/ Certified Material Test Report (CMTR) showing details of physical and
chemical properties may be collected from supplier along with these tests.