You are on page 1of 2

TECHNICAL DATA

Fluke T6 Electrical Testers


with FieldSense technology

Measure voltage…without test leads


Measure voltage up to 1000 V ac through the open fork, without test
lead contact to live voltage.+ Without opening covers or removing
wire nuts. On wires up to AWG 4/0 (120 mm2), carrying as much as
200 A. It will change your job. Safer. Faster. Easier.

Product Highlights
• FieldSense technology for ac voltage, current and frequency
measurement without making electrical contact to live voltage+
• Simultaneous voltage and current display (T6-1000)—
shows all power supply measurements at a glance for
efficient troubleshooting
• 1 to 1000 V ac or dc (T6-1000); 600 V ac or dc (T6-600)
• 0.1 to 200 A ac
• Resistance 1 Ω to 100 kΩ (T6-1000), 1 Ω to 2 kΩ (T6-600)
• Frequency measurement 45 Hz to 66 Hz (T6-1000)
• Works with wires up to AWG 4/0 (120 mm2) with a
17.8 mm jaw opening.
• HOLD button temporarily freezes the reading for easy viewing
• Easy to read display with backlight
• Accepts optional Fluke TPAK Magnetic Meter Hanger for
convenient operation
• Standard two-year warranty; extendable to four years through
product registration within 45 days of purchase*
+ Requires capacitive path to ground, provided through user in most applications.
Ground connection via test lead may be required in some situations.
* Register product online within 45 days of purchase to extend warranty to four years.
See http://a.fluke.com/registration for details.
Specifications
Measurement Specifications
T6-600 T6-1000
Function Requires test leads Range Range Resolution Accuracy [1]

FieldSense ac voltage No 600 V 1000 V 1V ±(3 % + 3 counts) [2] [3]


45 Hz - 66 Hz
±(3 % + 3 counts)
FieldSense ac current No 200.0 A 200.0 A 0.1 A
45 Hz - 66 Hz
FieldSense frequency
No 45 Hz – 66 Hz 1 Hz ±(1 % + 2 counts) [3]
(Hz)
±(1.5 % + 2 counts)
Volts ac Yes 600 V 1000 V 1V
45 Hz - 66 Hz
Volts dc Yes 600 V 1000 V 1V ±(1 % + 2 counts)
Resistance Yes 2000 Ω 2000 Ω 1Ω ±(1 % + 2 counts)
Yes 20.00 kΩ 0.01 kΩ ±(1 % + 2 counts)
Yes 100.0 kΩ 0.1 kΩ ±(1 % + 2 counts)
Safety 1000 V CAT III
600 V CAT III
(measurement category) 600 V CAT IV

Accuracy (1): ± ( [ % of reading] + [number of least significant digits] ). Accuracy is specified for 1 year after calibration, at 18 °C to 28 °C (64 °F to 82 °F)
with relative humidity to 90 %. AC conversions are ac-coupled, RMS responding.
Accuracy (2): Add 3 % without an external ground connection. External ground connection required for user wearing insulated gloves, standing on an
insulated ladder and otherwise insulated from earth ground.
Accuracy (3): FieldSense specified from 16V to 100% of range.

General Specifications
Calibration 1-year calibration cycle
Dimensions 61.1 mm x 259.3 mm x 43.8 mm
Weight 0.35 kg (0.78 lb)
Fork opening 17.8 mm
Temperature
Operating: -10 °C to +50 °C (14 °F to 122 °F)
Storage: -30 °C to +60 °C (-22 °F to +140 °F)
Altitude
Operating: 2,000 m (6,562 feet)
Storage: 10,000 m (32,808 feet)
Relative Humidity 0 % to 90 %, 5 °C to 30 °C (41 °F to 86 °F)
0 % to 75 %, 30°C to 40 °C (86 °F to 104 °F)
0 % to 45 %, 40°C to 50 °C (104 °F to 122 °F)

Battery Type and Life 2 x AA (IEC LR6); 360 hours continuous, typical; 200 hours using
FieldSense
Temperature coefficient 0.1 x (specified accuracy) / °C for <18°C or >28 °C
(< 64.4 °F or > 82.4 °F)
Safety IEC/EN 61010-1, IEC/EN 61010-2-033: Pollution Degree 2
Electromagnetic Environment IEC/EN 61326-1: Portable

Fluke. Keeping your world


Ordering information up and running.®
Fluke T6-600 Electrical Tester
Fluke Corporation
Fluke T6-1000 Electrical Tester PO Box 9090, Everett, WA 98206 U.S.A.
Included with product Fluke Europe B.V.
PO Box 1186, 5602 BD
Attached test leads with removable 4 mm probe caps,
Eindhoven, The Netherlands
user documentation
Modification of this document is not
Optional accessories permitted without written permission
from Fluke Corporation.
H-T6 Belt Holster
For more information call:
TPAK Magnetic Hanger In the U.S.A. (800) 443-5853 or
PRV240FS Proving Unit Fax (425) 446-5116
TP1 Probe Set, Flat-Blade (US/UK flat tip) In Europe/M-East/Africa +31 (0)40 267 5100
or Fax +31 (0)40 267 5222
TP38 Probe set, round (EU) In Canada (800)-36-FLUKE or
AC285 SureGrip Alligator Clips Fax (905) 890-6866
From other countries +1 (425) 446-5500 or
AC220 SureGrip Alligator Clips
Fax +1 (425) 446-5116
Service Information Sheet, PN 686953 Web access: http://www.fluke.com
©2017 Fluke Corporation.
Specifications subject to change without notice.
* Two-year additional warranty offer may be discontinued without notice 8/2017 6009251b-en

2 Fluke Corporation Fluke T6 Electrical Testers with FieldSense technology

You might also like