Calibration with bielomatik control unit 30063109


Step 1: Adjust fluidparameters for air pressure and oil pressure

Air pressure Oil pressure


4 bar – 10 bar 15 bar

Step 2: Clamp HSK tool holder into spindle

Kalibrieren mit bielomatik Steuergerät 30063109 19.10.2012_Seite_1/8


bielomatik
Step 3: Vent the lance and the HSK tool holder.

Adjust the bielomatik control unit as in the following pictures shown:

Note: Each parameter you can select with the ENTER button. Press +/- button to
change the settings into the different menus.

After changing the settings, it is necessary to press the ENTER button twice to safe the
modified parameters.

INTEGRADE VALUE?
ENTER=yes

1 2

SELECT VARIANT: OPERATING MODE


29 BA1 INTERNAL

3 4

CYCLE TIME IN OPENING TIME IN


0.10 s 45.00 ms

AIR CURRENT
0 %

After completing the settings of parameter 1-5, press ESC button to return to main menu.
To activate the oil flow press the + and – buttons on the control unit together. The OK light
will flash. Make sure there is oil flow out of the tool. Allow oil to flow for one minute and stop
by pressing the ESC button.

Kalibrieren mit bielomatik Steuergerät 30063109


bielomatik
Then connect the calibration unit with the HSK tool holder.

Step 4: Adjust a variant to purge the Measurement Unit.

Note: After each measuring procedure it is necessary to purge the measurement unit.

1 2

SELECT VARIANT: OPERATING MODE


31 BA1 INTERNAL

3 4

CYCLE TIME IN OPENING TIME IN


0.00 s 0.05 ms

AIR CURRENT
100 %

Kalibrieren mit bielomatik Steuergerät 30063109


bielomatik

Step 5: Adjust a variant to calibrate

Note: During the calibration it is necessary to adjust a backpressure of 2 bar at the gauge on
the measurement Unit.

1 2

SELECT VARIANT: CYCLE TIME IN


30 0.00 s

3 4

OPENING TIME IN AIR CURRENT


0.05 ms 32 %

After completing the settings of parameter 1-4, activate MQL from the machine control.

AIR CURRENT
32 %

If the backpressure is not at 2 bar, adjust it with + or


– button.

Switch off MQL.

Kalibrieren mit bielomatik Steuergerät 30063109


bielomatik

Complete the settings in variant 30 to start the calibration.

5 6

CYCLE TIME IN OPENING TIME IN


0.10 s 1.00 ms

Step 6: Prepare the Input Basic Data Sheet.

Kalibrieren mit bielomatik Steuergerät 30063109


bielomatik

Step 7: Insert the calibration data.

Note: The following calibration results are only an example.

OPENING TIME 0,50ms OPENING TIME 0,55ms OPENING TIME 0,60ms


Measuring point 1 Measuring point 1 Measuring point 1

If the readings are not exactly the same as in the Oil Flow Reference shown (14,4 /
36 / 90 / 235 / 432 ) choose the closest value you have found.

Kalibrieren mit bielomatik Steuergerät 30063109


bielomatik

OPENING TIME 1,00ms OPENING TIME 6,40ms OPENING TIME 21,20ms OPENING TIME 44,00ms
Measuring point 2 Measuring point 3 Measuring point 4 Measuring point 5

During the calibration procedure you always have to switch between variant 30 and 31.
Activate the variants via the machine controller. Variant 30 to measure, variant 31 to purge.
Measure and purge as long as all targets for Oil Flow Reference been found.

Activate the purge activity for minimum 1 minute.

Step 8: Prepare Input Oil Flow targets

Note: Variants 1 – 30 can be programmed user defined. See example.

Kalibrieren mit bielomatik Steuergerät 30063109


bielomatik
Step 9: Insert control parameters into the bielomatik MQL controller

Example for variant 1:


Cycle Time 0,28 sec
Opening Time 0,55 ms
Air Current 100 %

Kalibrieren mit bielomatik Steuergerät 30063109