Professional Documents
Culture Documents
Gmi Isbarriers DTS0769 r2
Gmi Isbarriers DTS0769 r2
Gmi Isbarriers DTS0769 r2
BARRIERS
Company Safety, performance and reliability
profile OUR PRODUCTS, OUR COMMITMENT
GM International designs, engineers and manufactures a complete range of
Intrinsically Safe and SIL Certified Devices.
For automation packages, DCS - ESD - FGS - BMS - HIPPS - PLC - SCADA - MARINE,
in several industrial sectors: Oil and Gas, Petrochemical, Pharmaceutical, Fertilizer,
Mining, Food.
40 years of Experience
founded in 1993,
former Elcon Instruments
100% Internal Production
in State-of-the-Art facilities
near Milan, Italy
Global Player
with presence in 5 continents
G.M. International © All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights. 2
Company GMI Safety Solutions
profile
G.M. International © All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights. 3
Company Quality and innovation
profile OUR GOALS
We guarantee the highest standard of quality
G.M. International © All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights. 4
Company Think local, act global
profile WORLDWIDE PRESENCE
G.M. International © All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights. 5
Company Reference List
profile
System vendors E.P.C. O.E.M. End users
ABB AMEC FOSTER ABB OY DRIVES 3M
EMERSON WHEELER ACCAGEN SA ADMA-OPCO
GEBHARDT BECTEL APPLIED WEIGHING INT. AGIP
AUTOMATION FLUOR BOBST GROUP ARAMCO
HIMA HHI BASF
CAMERON
HONEYWELL JACOBS BHP
CANRIG DRILLING TECH. BP
ICS TRIPLEX L&T CLAMPON CIBA GEIGY
INVENSYS MCDERMOTT DRESSER RAND CAMERON
SIEMENS NPCC FMC ENEL
SCHNEIDER SAIPEM GE ENI
ROCKWELL PARSONS HALLIBURTON EXXON-MOBIL
AUTOMATION PETROFAC HANLA LEVEL GASCO
YOKOGAWA SK ENGINEERING INKMAKER KOC / KNPC
SNC-LAVALIN KONGSBERG SEATEX LOTOS
TECNIMONT ONGC
NOV
TECHNIP-FMC ORLEN
PRECIAMOLEN
TR PFIZER
SCHLUMBERGER SASOL
WORLEY SIEMENS IND. TURBINES SHELL
SKANA KOREA HYDRA. SIRTE OIL
WARTSILA NORWAY STATOIL
WEATHERFORD TOTAL
G.M. International © All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights. 6
Intrinsically
Safe Barriers
Technology
Hazardous Explosive atmosphere
Area
The hazardous area is a dangerous combination of
Flammable Substances, Oxygen and Sources of Ignition
that can generate an explosion.
G.M. International © All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights. 8
Hazardous Protection methods
Area
How to power and read signals from the field devices installed in the
hazardous area?
There are different methods based on different principles such as:
G.M. International © All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights. 9
Hazardous Intrinsic safety
Area
Since Intrinsic safety is the most flexible and cost-effective
solution it has been standardized in many applications.
Based on ATEX Directive 2014/34/EU a specific device must
be connected between the power source and the field
devices to make the system safe.
This unit is called “Intrinsically Safe Barrier” or just “Barrier”.
Cables
Is
Apparatus
G.M. International © All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights. 10
Hazardous Galvanic isolators vs. Zener barriers
Area
Galvanic Isolator Barrier Zener
↑ No Safety Ground requirement (No cost / ↓ Dedicated Safety Ground Cost (installation
No maintenance) & maintenance costs)
↑ Better overall accuracy
↓ Requires routine Checks
↑ Lower installation cost
↑ Signal standardization (i.e 4-20mA, contact,…) ↓ Field sensor must be isolated
↑ Allows the use of grounded or poorly ↓ Zener leakage Infl. Accuracy
isolated sensors
Current limiting resistor Transformer Protecting Fuse Current limiting resistor Zener Protecting Fuse
+
+
= ≈ I.S. Voltage limiting
I.S.
Circuit Circuit Zeners
≈ =
- Safety Ground
-
Hazardous Area Safe Area Hazardous Area Safe Area
G.M. International © All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights. 11
Intrinsically
Safe Barriers
G.M. International © All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights. 13
Intrinsically Manufacturing excellence
safe barriers ENCLOSURE
Dimensions
A scalable dimension; 12,5 mm width optimizes cabinet
space
Density
Up to 6 mm per channel ( 3mm for DI)
Foot print
160 Channels in only 1 mt
Wiring
Terminals protected by the enclosure
G.M. International © All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights. 14
Intrinsically Manufacturing excellence
safe barriers WIDE TEMPERATURE RANGE
Operating temperature certified from -40°C to +70°C
Longer lifetime
Capability to withstand higher temperatures, improves the
lifetime in normal conditions (i.e. 30 °C).
Two devices with different temperature rating (i.e. +60°C and
+70°C) operating in the same environment (i.e. +50°C) have
different life expectancy; where the lower rated is
significantly shorter.
G.M. International © All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights. 15
Intrinsically Manufacturing excellence
safe barriers ONLY ONE PRODUCT FOR ALL APPLICATIONS
Universal mounting units
DIN-rail stand-alone devices
Standard and customized termination boards
Power bus using standard TS 35 DIN-rail
The same device can be used in all applications to reduce spare inventory.
G.M. International © All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights. 16
Intrinsically Manufacturing excellence
safe barriers SPECIAL DUAL CHANNEL FEATURE
Dual Power Supply, 2 totally independent circuits.
Independent SIL certified Dual Channel.
5+
= Supply 24 Vdc
=
Channel 1 6-
=
2 Wire Tx HHT HHT Source I
+ 7 1 +
? =
In 1 8 2 mA RL Out 1
I - = -
=
=
Channel 2 2 Wire Tx HHT
=
HHT Source I
+ 9 3 +
? =
In 2 10 4 mA RL Out 2
I - = -
- + Termination
Power Bus board
connector
G.M. International © All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights. 17
Intrinsically AI - Analog inputs
safe barriers
Alarm
In Out Duplicator Other SIL Hart Size
N. out
L.M.
Ch
Active Passive Source Sink
G.M. International © All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights. 18
Intrinsically AO - Analog outputs
safe barriers
Ch L.M. Output type Hart Fault output SIL Size
G.M. International © All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights. 19
Intrinsically DI - Digital inputs
safe barriers
Ch. L.M. Output Duplicator Other SIL Size
G.M. International © All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights. 20
Intrinsically DO - Digital outputs
safe barriers
Ch. L.M. Output Power supply Other SIL Size
D5040 1/2 - Solenoid valve / LED Loop powered 2..4 Field Selectable Outputs SIL3 12,5 mm
D5048S 1 Solenoid valve / LED Loop powered 1..3 Field Selectable Outputs SIL3 12,5 mm
D5049S 1 Solenoid valve / LED Bus powered 1..3 Field Selectable Outputs SIL3 12,5 mm
D5240T 3 - Solenoid valve / LED Bus powered 3..9 Field Selectable Outputs SIL2 22,5 mm
D5244 1/2 - Relay Loop powered Voltage Free Relay Output SIL2 22,5 mm
Bus Powered /
D1040Q 4 - Solenoid valve / LED 1..4 Field Selectable Outputs SIL3 22,5 mm
Loop powered
Bus Powered / 1..4 Field Selectable Outputs
D1041Q 4 - LED SIL3 22,5 mm
Loop powered (LED Driver)
Bus Powered /
D1042Q 4 - Solenoid valve / LED 1..4 Field Selectable Outputs SIL3 22,5 mm
Loop powered
Bus Powered /
D1043Q 4 - Solenoid valve / LED 1..4 Field Selectable Outputs SIL3 22,5 mm
Loop powered
D1044 1/2 - Relay Loop powered Voltage Free Relay Output SIL2 22,5 mm
G.M. International © All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights. 21
Intrinsically Universal temperature: TCs, RTDs, mV, Ω,
safe barriers Potentiometers
Alarm
Ch. L.M. OUTPUT type Duplicator Modbus SIL Size
output
D5072 1/2 0/4-20 mA Yes SIL2 12,5 mm
G.M. International © All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights. 22
Intrinsically Others
safe barriers
Function
D5062S Vibration transducer interface
D5263S Strain Gauge Bridge Isolating Repeater
D5264S Strain Gauge Bridge Isolating Converter
D5202S Power distribution and diagnostic module
D1035S Frequency Repeater
D1060S Frequency-Pulse Converter, Repeater and Trip Amplifier
D1061S RS 422 / RS 485 Isolating Repeater
D1062S Vibration Transducer Interface
D1063S Load Cell / Strain Gauge Bridge Isolating Repeater
D1064S Load Cell / Strain Gauge Bridge Isolating Converter
D1010-054 Fast Response mV to mA Converter
D1080D Flammable Liquid Presence Detector Interface Relay Output
D1081D Flammable Liquid Presence Detector Interface Transistor Output
G.M. International © All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights. 23
Intrinsically Series comparison
safe barriers
D1000 D5000
G.M. International © All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights. 24
Intrinsically Online information
safe barriers
Visit our website
www.gminternational.com to find a
wide range of services and
information such us:
Downloads
Product details
Certifications
News
Software and web-based tools
Worldwide contacts
G.M. International © All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights. 25
THANK YOU
www.gminternational.com
DTS0769 Rev. 2