You are on page 1of 2

Case History

SureFlo 298Ex Flowmeter Delivered


Smart Well Completion Efforts
Reduced wireline runs and captured high-resolution data

Benefits
„„ Saved two wireline runs in
high-cost environment
„„ Minimized well pressure loss,
increasing operation efficiency
„„ Improved water flooding efficiency
prediction with accurate deter-
mination of zonal injection rate

Background and challenges


„„ Chevron and Cabinda Gulf Oil
Company joint project
„„ Tombua Landana field,
Cabinda, Angola
„„ Wireline-actuated downhole In order to maintain a more cost-effective Even though Baker Hughes has the
valve assembly method of deploying a smart well for SureFlo™ 298 flowmeter, providing
injector wells, an operator uses a downhole accurate flow with a wireline retrievable
Baker Hughes solution and results valve which is actuated on a wireline venturi sleeve, the process of retrieving
„„ SureFlo 298Ex flowmeter assembly. The ability to monitor the amount a flowmeter from a subsea well is cost
downhole flowmeter of injected fluid into each zone is another prohibitive. In order to minimize rig time
„„ Reduced two wireline runs important criterion in deploying a smart from multiple wireline runs, Baker Hughes
required to actuate the valve— injector well. proposed an industry first—deploy the
saving approximately USD SureFlo 298Ex flowmeter with electronic
6 million in rig time Chevron and the Cabinda Gulf Oil Company fullbore access.
were developing the Tombua Landana field
in the Eastern part of Block 14, offshore
Cabinda, Angola, with water depths between
886–1,214 ft (270–370 m). The operators
deployed two injector wells with wireline
actuated downhole valve technology.

Baker Hughes supplied the downhole


flowmeter and gauges to provide zonal
injection allocation and zone pressure
monitoring. Most downhole flowmeters in
the industry are venturi-based technology Wireline tool passing through
SureFlo™ 298Ex flowmeter
and restrict wireline access through
the flowmeter.
This tool has a full bore providing up to
98% accuracy in its measurement. This
technology uses the high-resolution, high-
accuracy SureSENS™ gauges, enabling small
differential pressure to be detected reliably.

With rig costs reaching USD 6 million per


day in the Angola region, plus the cost of
each wireline run, it soon became apparent
that using a standard wireline venturi was
not feasible for this application.

By running a SureFlo 298Ex flowmeter, it is


possible to reduce two additional wireline
runs and the associated rig time. A client
can save a considerable amount of money
without any loss in accuracy of measurement
compared to conventional venturi.

www.bakerhughes.com
Disclaimer of Liability: This information is provided for general information purposes only and is believed to be accurate as of the date hereof; however, Baker Hughes Incorporated and its affiliates do
not make any warranties or representations of any kind regarding the information and disclaim all express and implied warranties or representations to the fullest extent permissible by law, including
those of merchantability, fitness for a particular purpose or use, title, non-infringement, accuracy, correctness or completeness of the information provided herein. All information is furnished “as is”
and without any license to distribute. The user agrees to assume all liabilities related to the use of or reliance on such information. BAKER HUGHES INCORPORATED AND ITS AFFILIATES SHALL NOT BE
LIABLE FOR ANY DIRECT, INDIRECT, SPECIAL, PUNITIVE, EXEMPLARY OR CONSEQUENTIAL DAMAGES FROM ANY CAUSE WHATSOEVER INCLUDING BUT NOT LIMITED TO ITS NEGLIGENCE.

© 2011 Baker Hughes Incorporated. All rights reserved. 28986

You might also like