G5V-1

Low Signal Relay

Ultra-miniature, Highly Sensitive


SPDT Relay for Signal Circuits
• Ultra-miniature at 12.5 × 7.5 × 10 mm (L × W × H).
• Wide switching power of 1 mA to 1 A.
• High sensitivity: 150 mW nominal coil power consumption.
• Fully-sealed construction offering environment resistance.
• Conforms to FCC Part 68 requirements for coil to contacts.
(1,500 V, 10 × 160 μs)
• Models for ambient temperatures up to 90°C added to series.

RoHS Compliant

■Model Number Legend ■Application Examples


G 5 V-@- @ 1. Number of Poles/Contact Form • Telecommunication equipment
— — 1: 1-pole/SPDT (1c) • Audio-visual products
1 2
• Security equipment
2. Classification
• Building automation equipment G
None: Standard (Ambient operating temperature 70°C max.) 5
T90: Ambient operating temperature 90°C max. V

-
1
■Ordering Information ■Standard Model Specifications
Enclosure Terminal Rated coil Minimum Contact type: Single crossbar (Au-alloy + Ag)
Classification Contact form Model
rating Shape voltage packing unit Enclosure rating: Plastic sealed
3 VDC
5 VDC Terminal shape: PCB terminals
6 VDC
Standard G5V-1
9 VDC
Fully SPDT PCB
12 VDC 25 pcs/tube
sealed (1c) terminals
24 VDC
5 VDC
G5V-1-T90 G5V-1-T90 12 VDC
24 VDC
Note: When ordering, add the rated coil voltage to the model number.
Example: G5V-1 DC3
Rated coil voltage
However, the notation of the coil voltage on the product case as well as on the packing will be marked as @@ VDC.

■Ratings
●Coil ●Contacts
G5V-1 (Standard) Load
Resistive load
Must operate Must release Item
Rated Coil Max. voltage Power
voltage voltage Contact type Single crossbar
Rated voltage current resistance (V) consumption
(V) (V) Contact
(mA) (Ω) (mW) Au-alloy + Ag
% of rated voltage material
3 VDC 50 60 0.5 A at 125 VAC;
5 VDC 30 167 Rated load
1 A at 24 VDC
6 VDC 25 240 200% at Rated carry
80% max. 10% min. Approx. 150 2A
9 VDC 16.7 540 23°C current
12 VDC 12.5 960 Max. switching
24 VDC 6.25 3,840 125 VAC, 60 VDC
voltage
G5V-1-T90 Max. switching
1A
current
Must operate Must release
Rated Coil Max. voltage Power
voltage voltage
Rated voltage current resistance (V) consumption
(V) (V)
(mA) (Ω) (mW)
% of rated voltage
5 VDC 30 167
200% at
12 VDC 12.5 960 70% max. 10% min. Approx. 150
23°C
24 VDC 6.25 3,840
Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance
of ±10%.
2. The operating characteristics are measured at a coil temperature of 23°C.
3. The maximum voltage is the highest voltage that can be imposed on the relay coil.
4. G5V-1-2 types with a must operate voltage of 70% max. are available as special series products.

1
G5V-1 Low Signal Relay

■Characteristics
Contact resistance *1 100 mΩ max.
Operate time 5 ms max.
Release time 5 ms max.
1,000 MΩ min. (at 500 VDC between coil and contacts,
Insulation resistance *2
at 250 VDC between contacts of same polarity.)
Dielectric Between coil and contacts 1,000 VAC, 50/60 Hz for 1 min
strength Between contacts of the same polarity 400 VAC, 50/60 Hz for 1 min
10 to 55 to 10 Hz, 1.65 mm single amplitude Note: The values here are initial values.
Destruction *1. Measured with 10 mA at 1 VDC with a voltage drop
Vibration (3.3 mm double amplitude)
resistance method.
10 to 55 to 10 Hz, 1.65 mm single amplitude
Malfunction *2. Measured with a 500 VDC megohmmeter between
(3.3 mm double amplitude)
coil and contacts and a 250 VDC megohmmeter
Shock Destruction 1,000 m/s2
between contacts with the same polarity applied to
resistance Malfunction 100 m/s2
the same parts as those used for checking the
Mechanical 5,000,000 operations min. (at 36,000 operations/hr) dielectric strength.
Durability 100,000 operations min. *3. This value was measured at a switching frequency
Electrical
(under rated load, at 1,800 operations/hr) of 120 operations/min and the criterion of contact
Failure rate (P level) (reference value) *3 1 mA at 5 VDC resistance is 100 Ω.
-40°C to 70°C (Standard), -40°C to 90°C (G5V-1-T90) This value may vary depending on the switching
Ambient operating temperature
(with no icing or condensation) frequency and operating environment. Always
Ambient operating humidity 5% to 85% double-check relay suitability under actual operating
Weight Approx. 2 g conditions.

G
5
V
-

2
G5V-1 Low Signal Relay

■Engineering Data
●Maximum Switching Capacity ●Durability ●Ambient Temperature vs.
Maximum Coil Voltage
5 500 250
Switching current (A)

Maximum coil voltage (%)


Durability (x104 operations)
3 300

200

24 VDC resistive load


G5V-1-T90
100
1 150
70
0.7 50

0.5 100
30

0.3 Standard

125 VAC 50
10 resistive load
DC resistive load AC resistive
7
load
0.1 5 0
10 30 50 70 100 300 500 0 0.2 0.4 0.6 0.8 1.0 1.2 −40 −20 0 20 40 60 70 80 90 100
Switching voltage (V) Switching current (A) Ambient temperature (°C)
Note: The maximum coil voltage refers to the
maximum value in a varying range of operating
power voltage, not a continuous voltage.
●Ambient Temperature vs. Must ●Shock Malfunction
Operate or Must Release Voltage
G5V-1 G5V-1-T90
On the basis of rated voltage (%)

100 100 Y
On the basis of rated voltage (%)

Sample: G5V-1 Sample: G5V-1-T90 1,000 G


Number of Relays: 10 pcs
max.
Number of Relays: 10 pcs 5
800
80 X 80 max. V

-
X 600 Z
min. −
X 1,000 1,000 1
400
60 60 min.
200

200
40 max. 40
max. 400 De-
X 1,000 1,000
− energized
X Z' 600 X'
min. min.
20 20 800
Shock direction
X X' Energized
Must operate voltage Must operate voltage 1,000
Must release voltage Must release voltage Y Y'
0 0 Z Unit: m/s2
-60 -40 -20 0 20 40 60 80 100 −60 −40 −20 0 20 40 60 80 100 Z' Sample: G5V-1 12 VDC
Y' Number of Relays: 10 pcs
Ambient temperature (°C) Ambient temperature (°C)
Test conditions: Shock is applied in ±X, ±Y, and
±Z directions three times each with and without
energizing the Relays to check the number of
contact malfunctions.
●Dial Pulse Test *1 ●Contact Reliability Test *1, *2
80 1,000
On the basis of rated voltage (%)

Contact resistance (mΩ)

Sample: G5V-1 12 VDC NO contact


70 Must operate voltage Number of Relays: 10 pcs
max.
60 500 Test conditions: Resistive NC contact
load at 5 VDC 1 mA
50 min. 400
Switching frequency:
Must release voltage max. 300 7,200 operations/h
40
30 200
20 min.
Sample: G5V-1 12 VDC
10 Number of Relays: 6 pcs 100
max.
1,000 Test conditions: Contact load
WJ-139 (with arc-killer) max.
500
Contact resistance (mΩ)

Switching frequency: 20PPS 50 max.


300 40
NO NC 30
100 contact contact min.
50 20 min.
Contact resistance max.
30
min.
10 min. 10
0 50 100 500 1,000 5,000 10,000 50,000 0 5 10 50 100 500 1,000
3
Rotation (×10 turns) Operating frequency (×104 operations)

*1. The tests were conducted at an ambient temperature of 23°C.


*2. The contact resistance data are periodically measured reference values and are not values from each monitoring operation. Contact resistance values will vary
according to the switching frequency and operating environment, so be sure to check operation under the actual operating conditions before use.

●High-frequency Characteristics
• Test Conditions
G5V-1
HR 8502A RF HR 8502A
Network Transmission
R
analyzer HP A reflection
8501A test-set
50Ω
Storage Terminator Note: The high-frequency characteristics data were measured using a dedicated circuit board and
normalizer B
actual values will vary depending on the usage conditions. Check the characteristics of the actual
Terminals which were not being measured were terminated with 50 Ω. equipment being used.
Measuring impedance: 50 Ω

3
G5V-1 Low Signal Relay

●High-frequency Characteristics ●High-frequency Characteristics ●High-frequency Characteristics


(Isolation) *1, *2 (Insertion Loss) *1, *2 (Return Loss, V.SWR) *1, *2
(Average value (initial)) (Average value (initial)) (Average value (initial))
0

Insertion loss (dB)


0 0
Isolation (dB)

Return loss (dB)

V.SWR
1.4
Sample: G5V-1 Sample: G5V-1
Number of Relays: 5 pcs Number of Relays: 5 pcs

20 10 1.3
0.5

40 20 1.2

Between a-c 1.0


Return loss
60 30 1.1

Between b-c 1.5


80 40 1.0
Sample: G5V-1 V.SWR
Number of Relays: 5 pcs
Frequency (MHz)
100 2.0 50
1 3 5 10 30 50 100 1 3 5 10 30 50 100 1 3 5 10 30 50 100
Frequency (MHz) Frequency (MHz) Frequency (MHz)

●Must Operate and Must Release ●Distribution of Bounce Time *1


Time Distribution *1
30 30
Number of contacts

Number of contacts

Sample: G5V-1 12 VDC Must operate time Sample: Operating bounce time
Number of Relays: 50 pcs G5V-1 12 VDC
Must release time Number of Relays: Release bounce time
25 25 50 pcs

20 20
G
5
V 15 15
-

1 *1. The tests were conducted at an ambient


10 10 temperature of 23°C.
*2. High-frequency characteristics depend on
the PCB to which the Relay is mounted.
5 5 Always check these characteristics,
including endurance, in the actual machine
before use.
0 0.5 1 1.5 2 2.5 3 3.5 4 0 1 2 3 4 5 6 7 8
Time (ms) Time (ms)

■Dimensions
G5V-1 PCB Mounting Holes Terminal Arrangement/
(Bottom View) Internal Connections
7.5 max. (Bottom View)
(7.3)* 2.54 6-1 dia. holes
12.5 max.
(12.3)* 2.54 (1.11)

10 max. 5.08±0.1 1 2 5
(9.9)* 0.5
10 9 6
3.5 (1.11)
(No coil polarity)
2.54 7.62
0.5 0.5
(1.07) (1.07)
0.3 0.3 10.16±0.1
* Average value Note: indicate the product's directional marks.
Note: Each value has a tolerance of ±0.3 mm.

■Approved Standards ■Precautions


UL recognized: (File No. E41515) • Please refer to “PCB Relays Common Precautions” for correct
CSA certified: (File No. LR31928) use.
Contact Number of test
Model
form
Coil ratings Contact ratings
operations
Correct Use
1 A, 30 VDC at 40°C • Long-term Continuously ON Contacts
SPDT 6,000
G5V-1 3 to 24 VDC 0.3 A, 110 VDC at 40°C
(1c) Using the Relay in a circuit where the Relay will be ON
0.5 A, 125 VAC at 40°C 100,000
SPDT 1 A, 30 VDC at 90°C 100,000 continuously for long periods (without switching) can lead to
G5V-1-T90 5 to 24 VDC unstable contacts, because the heat generated by the coil itself
(1c) 0.5 A, 125 VAC at 90°C 100,000
will affect the insulation, causing a film to develop on the contact
surfaces. Be sure to use a fail-safe circuit design that provides
protection against contact failure or coil burnout.
• Relay Handling
When washing the product after soldering the Relay to a PCB,
use a water-based solvent or alcohol-based solvent, and keep
the solvent temperature to less than 40°C. Do not put the Relay
in a cold cleaning bath immediately after soldering.

4
G5V-1 Low Signal Relay

G
5
V

-
1

• Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.
• Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or
equipment, and be sure to provide the system or equipment with double safety mechanisms.

Note: Do not use this document to operate the Unit.