Professional Documents
Culture Documents
LF RELAYS
Product Catalog
2023.7
Power Relays ( Over 2 A )
LF RELAYS
Ideal for compressor and inverter loads, 1 Form A 20 A, Power relays
TYPICAL APPLICATIONS
(Unit:mm)
ALF 1
TYPES
RATING
■ Coil data
• Operating characteristics such as " Operate voltage " and " Release voltage " are influenced by mounting conditions or
ambient temperature, etc.
Therefore, please use the relay within ±5 % of rated coil voltage.
• " Initial " means the condition of products at the time of delivery.
■ Specifications
Item Specifications
Contact arrangement 1 Form A
Contact resistance
Max. 100 mΩ ( by voltage drop 6 V DC 1 A )
( initial )
Contact material AgSnO2 type
Contact rating ( resistive ) 20 A 250 V AC
Contact data Max. switching
6,250 VA
power ( resistive )
Max. switching voltage 250 V AC
Max. switching current 25 A ( AC )
Min. switching load
100 mA 5 V DC
( reference value ) *1
Insulation resistance ( initial ) Min. 1,000 MΩ ( at 500 V DC, Measured portion is the same as the case of dielectric strength. )
Dielectric Between open contacts 1,000 V rms for 1 min ( detection current: 10 mA )
strength Between contact
( initial ) 5,000 V rms for 1 min ( detection current: 10 mA )
and coil
Surge withstand Between contact
10,000 V
voltage ( initial ) *2 and coil
Time Operate time Max. 20 ms at rated coil voltage ( at 20 ℃, without bounce )
characteristics
( initial ) Release time Max. 15 ms at rated coil voltage ( at 20 ℃, without bounce, with diode )
Functional 100 m/s2 ( half-sine shock pulse: 11 ms, detection time: 10 µs )
Shock resistance
Destructive 1,000 m/s2 ( half-sine shock pulse: 6 ms )
REFERENCE DATA
25℃
Temperature rise(℃)
50 60℃
100
50 125V AC resistive load 40
30
10 250V AC resistive load
20
5
10
0
0 10 20 30 0 80 100 120
Contact current(A) Coil applied voltage(%V)
Miscontact:0times
Operation frequency:ON:OFF=1s:5s
Circuit: 10
2
Switch
0
0 3 6
No. of operations(×104)
Operate voltage
8
Max.
Ave.
LF relay contact 470μF
6 Min.
2,000μF Release voltage
Max.
100V AC 4 Ave.
470μF Min.
0
0 3 6
No. of operations(×104)
3-3. 250 V AC Electrical life test ( 250 V AC Compressor dummy load ) 3-4. Electrical life test
( 20 A 250 V AC Resistive load )
Tested sample:ALF1T12, 6 pcs. Tested sample:ALF1T12, 6 pcs.
Load:Inrush 70.7A, cosφ=0.7 Change of operate and release voltage Operation frequency:ON:OFF=1.5s:1.5s
Steady 20A, cosφ=0.9 12 12
compressor dummy 250V AC Contact welding:0times Contact welding:0times
0 0
0 5 10 0 10 20
No. of operations(×104) No. of operations(×104)
DIMENSIONS ( Unit: mm )
CAD The CAD data of the products with a CAD mark can be downloaded from our Website.
■ TMP type
CAD External dimensions Schematic
11.25 12.8 ( BOTTOM VIEW )
0.8 0.8 #250 terminal 6.4
FASTON #250
7.9
10.2
PC board side
23.3
( BOTTOM VIEW )
4
30.1
φ1.8 12.0
φ1.8
General tolerance 12.0 10.0
15.7
■ PCB type
CAD External dimensions Schematic
( BOTTOM VIEW )
23.3
0.5
( BOTTOM VIEW )
0.8 0.8 1.6 0.3
1.6 1.6 12 27.6
22 13.8
27.6 φ2.0 φ2.0
30.1
12.0
General tolerance
15.7
φ1.8 φ1.8
Less than 1mm:±0.1 12.0 10.0
Min. 1mm less than 3mm:±0.2
Min. 3mm:±0.3 Tolerance ±0.1
SAFETY STANDARDS
Each standard may be updated at any time, so please check our Website for the latest information.
■ VDE ( Approved )
Ambient
File No. Contact rating Operations
temperature
20 A 250 V AC ( cosφ = 1.0 ) 10 × 103 60 ℃
40009169
10 A 250 V AC ( cosφ = 0.4 ) 100 × 103 70 ℃
■ TV rating
File No. Contact rating
UL: E43028 TV-8
Item Characteristics
Clearance/Creepage distance ( IEC61810-1 ) Min. 5.5 /5.5 mm
Category of protection ( IEC61810-1 ) RT II
Tracking resistance ( IEC60112 ) PTI 175
Insulation material group III a
Over voltage category III
Rated voltage 250 V
Pollution degree 2
Type of insulation ( Between contact and coil ) Reinforced insulation
Type of insulation ( Between open contacts ) Micro disconnection
Note) Actual value
■ For cautions for use, please read " GUIDELINES FOR RELAY USAGE ".
https://industrial.panasonic.com/ac/e/control/relay/cautions_use/index.jsp
■ For cautions for use, please read " GUIDELINES FOR RELAY USAGE ".
https://industrial.panasonic.com/ac/e/control/relay/cautions_use/index.jsp
Ambient Environment
Others
■ Cleaning
• Although the environmentally sealed type relay ( plastic • Cleaning with the boiling method is recommended ( The
sealed type, etc. ) can be cleaned, avoid immersing temperature of cleaning liquid should be 40 ℃ or lower ).
the relay into cold liquid ( such as cleaning solvent ) Avoid ultrasonic cleaning on relays. Use of ultrasonic
immediately after soldering. Doing so may deteriorate the cleaning may cause breaks in the coil or slight sticking of
sealing performance. the contacts due to ultrasonic energy.