You are on page 1of 4

C.

DESIGN OF PURLINS
Live Load = 1000 Pa
Velocity of Wind = 260 KPH
Weight of Roofing = 49.05 Pa

Coefficient of Pressure on Windward side = 0.70


Coefficient of pressure on Leeward side = 0.18
Assumed Spacing of Purlins = 1 m
Spacing of Truss = 7.5 m
∅ = 4.23 ̊
Weight of Ceiling = 71.25 Pa

Weight of Long Span Roof


kg m
Wt. of Roof = 5 (9.81 )
m² s²
N
Wt. of Roof = 49.05

Depth = 106 mm
T – web = 7.11 mm
Bf = 103 mm
T – flange = 8.76 mm
Area = 2470 mm²
N
Weight = 190
m
Sx = 103 000 mmᶟ
Sy = 47 900 mmᶟ

55
N N N
W DL + LL = (49.05 + 1000 ) ( 1 m ) + 190
m² m² m
N
W DL + LL = 1239.05
m

ΣFx = 0
Wt = 1239.05 ( sin 4.23 ̊)
N
Wt = 91.39
m
WL ²
Mx =
8
1235.67(7.5)²
Mx =
8
Mx = 8688.30 N-m
WL ²
My =
32
91.39(7.5)²
My =
32
My = 160.65 N-m
Mx
f bx =
Sx
8688.30(1000)
f bx =
103 000
f bx = 84.35 MPa

My
f by =
Sy
160.65(1000)
f by =
47 900

f by = 3.35 MPa

56
f bx f by
+ = Should be < 1
0.66 Fy 0.75 Fy
84.35 3.35
+ = 0.53
0.66(248) 0.75(248)
0.53 < 1 OK !

57