Professional Documents
Culture Documents
Training
Contents
1 Challenges Facing DataClick
CentertoNetworks
add Title
in the Cloud Computing Era
3 ClickSwitches
Introduction to CloudEngine to add Title
2015 2019
US$2 billion
US$18 billion
93% of enterprises surveyed have run
IaaS applications or are assessing the 70% of SDN applications are deployed
IaaS model in data centers and enterprises
Storage
Virtualization Tenant1/Dept.1 Tenant2/Dept.2 TenantN/Dept.N
DC network deployment
Servers/storage
devices deployed in 3
days
3 to 6 months
Agile: Full programmability for agile Quality: Industry-leading quality, Easy O&M: Real-time health monitoring,
service provisioning
` providing best-in-class quality implementing minute-level fault locating
• Industry-leading Clos architecture, and VOQ-
• Network programmability: Creates
based cell switching mode • Visible: gRPC-based, subsecond-level, and
the world's first SDN-based E2E
Agile data center network using standard
• Patented front-to-back airflow design high-precision data collection using the
isolates cold and hot air channels subscription mode
Network Service Header (NSH) and
Segment Routing (SR) technologies. • Dynamic large buffer ensures non-blocking • Clear: millisecond-level cache monitoring,
switching providing high-precision monitoring data
• System programmability: The VRP
supports extensive APIs such as • Precise: network-wide path detection,
• Lossless Ethernet, constructing highly
OPS to quickly meet service achieving minute-level network fault
reliable HPC networks
requirements. demarcation
• MACsec hardware encryption, secure and
reliable
CE6870-48T6CQ-EI
CE8860-4C-EI CE6855/CE6856-48T6Q-HI
CE6810-32T16S4Q-LI
CE8850-32CQ-EI CE5855-48T4S2Q-EI
CE6865-48S8CQ-EI CE5850-48T4S2Q-HI
CE1800V CE7855-32Q-EI
1.Elastic
2.Virtualized
3.Agile
4.High Quality
5.Easy O&M
3 Click Switches
Introduction to CloudEngine to add Title
18*100GE 24*40GE
CE12800
Port
density 36*100G
Switching
capacity 1032 Tbit/s
… • 110k GE servers
Data
forwarding
Peer-Link
channel
…
Control signaling
channel
Dual-active detection (DAD) channel Dual-active monitoring channel
On-demand VS allocation, ensuring high Three-channel cluster, providing higher L2 link virtualization, providing 100% link usage
resource usage reliability
No need for STP, 100% link usage
1:16 virtualization at most Independent data, control, and DAD channels
Dedicated four GE ports for the control channel
Independent control planes, providing higher
Intra-VS exclusive resource usage Super-large cluster bandwidth, avoiding availability
network bottlenecks Member switches with independent control
Exclusive CPU and memory resources 10/40/100GE ports for the data channel planes, providing higher availability
Exclusive MAC/VLAN/FIB entries Less synchronization information, low CPU load,
3.2 Tbps super-large cluster bandwidth at most
and more stable
DC1 DC3
BGP EVPN
VXLAN
with EVPN
DC2
VNI VNI
MAC VTEP VTEP VTEP VTEP MAC
ARP ARP
... ...
Service A Service B
Netconf
VXLAN
SR over WAN
Fabric
VXLAN
Linux OS
Simplified deployment
The SDN controller defines
AC FW IDS LB NAT
service chains through drag-
and-drop operations.
Efficient forwarding
Provide traffic diversion for
one time, simple configuration,
service traffic forwarding, and
VAS
Resource
secure monitoring.
pool
Zero wiring on the Independent front-to- Cell switching, VoQ Counter-rotating turbo
backplane back air channels fans
Balanced traffic distribution,
Higher chassis bandwidth Uniform cooling, suitable for Strong and efficient airflow
higher bandwidth usage
data centers
• Industry-leading architecture design, best-in-class quality: Switch fabric units vertical to line
cards, Clos switching architecture, cell switching, and Virtual Output Queue (VoQ) mechanism
• Pioneering innovative energy-saving technologies: Front-to-back airflow design and counter-rotating fans
Ingress port Egress port Ingress port Egress port Ingress port Egress port Ingress port Egress port
Ingress distributed buffer mitigates buffer load on a On-demand allocation and dynamic adjustment of
single port and avoids head-of-line (HOL) blocking buffer on line cards
Data flow Buffer
CNP
VIQ: Preventing Packet Loss in the Chip Dynamic ECN Fast CNP
VIQ implements backpressure of egress Dynamic ECN implements low latency and Fast CNP improves the network
packets over the ingress, achieving zero high throughout through dynamic data convergence performance by 30%
packet loss. collection in traffic mode and dynamic through quick feedback congestion.
threshold adjustment.
…
Content feedback
…
50%
50%
Proper network 5 10
us
5 10
us
Millisecond-level cache monitoring Microsecond-level cache monitoring
Traditional NMS
VM VM VM VM VM VM VM VM VM VM VM VM
1 3 implementing precise fault locating
Line card1 Line card N Data Push subscription mode, Millisecond or second-level
generation flow sampling monitoring
Telemetry agent Telemetry agent
Structured YANG model driven High encoding and decoding efficiency
Forwarding engine Forwarding engine
gRPC transmission Reliable & high efficiency
Forwarding engine Forwarding engine
Switching
184/387 367/774 734/1,548
capacity(Tbit/s)
The CloudEngine 16808 has
Packet forwarding
a total of eight slots for 115,200 230,400 460,800
rate (Mpps)
LPUs
LPU slots 4 8 16
MPU 1+1
SFU slots 6 (scalable to 9 for future expansion)
Switching
Clos switching architecture, cell switching, VoQ
The CloudEngine 16808 architecture
has 12 fan trays
Number of fan trays 3 3 6
The The CloudEngine Number of power
16808 maximum has nine 6 10 20
supplies
SFUs and supports N+1 or
N+M redundancy DC:2200W(-48V/-60V)-
Power input
AC/HVDC:3000W(AC:220V, HVDC:240V/380V)
Packet
forwarding rate 17,280 34,560 17,280 34,560 51,840 69,120
(Mpps)
Architecture Clos architecture, cell switching, VoQ, and distributed large buffer
Switch fabric
2 4 6
units
48*10GE Base-T
12*100GE CFP2
36*40GE QSFP+ 48*GE SFP
24*10GE SFP+
24*40GE QSFP+
Port
100GE Line Card 40GE Line Card 10GE Line Card GE Line Card
Speed
CE-L48XS-
Card CE-L24XS-
EF
CE-L48XS- CE- CE-L48GS- CE-L48GT-
CE-L12CF-EG CE-L04CF-EF CE-L24LQ-EC1 CE-L36LQ-EG CE-48XT-EC
name EC ED L48XS-EC EA EA
12*100GE/ 4*100GE
24*40GE/ 36*40GE/ 48*10GE 48*GE
Port 24*40GE/ /8*40GE/ 24*10GE 48*10GE 48*10GE 48*10GE 48*GE SFP
96*10GE 144*10GE Base-T Base-T
96*10GE 40*10GE
IPv6 Multicast
routes 8K 8K 2K 2K 2K 2K 8K 2K 8K 2K 2K
VRF 4096
MACSEC N N N N N N N N N N N
ACL 60K 20K 40K 60K 20K 10K 20K 20K 20K 10K 10K
VXLAN L3 GW Y Y Y Y Y Y Y Y Y Y Y
Number of
4000
Broastcast Domains
Buffer 18GB 6GB 12GB 18GB 6GB 3GB 6GB 6GB 6GB 2GB 2GB
48*10GE optical +
16*100GE QSFP28 8*100G CFP2 36*40GE QSFP+ 2*40GE + 2*100GE
Port
Speed
100GE Line Card 40GE Line Card 10GE Line Card
CE- CE- CE- CE- CE- CE- CE- CE- CE-L48XS- CE-L48XS-
Card CE- CE-L48XS- CE-L48XS-
L36CQ- L36CQ- L36CQ- L36CQ- L12CQ- L16CQ- L36LQ- L24LQ- FG FD1
name L08CF-FG FDA FD
FD FG FD1 SD FD FD FD FD
48*10GE +
16*100GE/ 2*40GE +
36*100GE/ 36*100GE/ 36*100GE/ 36*100GE/ 12*100GE/
16*40GE/ CFP2 and 2*100GE/40
36*40GE/ 36*40GE/ 36*40GE/ 36*40GE/ 12*40GE/ 36*40GE/ 24*40GE/ 48*10GE/
Port 64*25GE/6 DWDM GE or 48*10GE 48*10GE
144*25GE/ 144*25GE/ 144*25GE/ 144*25GE/ 48*25GE/4 144*10GE 96*10GE 25GE
4*10GE interface 52*10GE +
144*10GE 144*10GE 144*10GE 144*10GE 8*10GE
8*25GE/10G
E
MAC 750K
ARP 750K 1M 104K 104K 750K 750K 1M 750K 750K 750K 750K 1M 750K
IPV4 FIB 380K 2M 750K 750K 380K 256K 2M 380K 380 380K 380K 4M 256K
IPV6 FIB 128K 512K 140K 140K 128K 128K 512K 128K 128K 128K 128K 512K 128K
IPv4 Multicast
32K
routes
IPv6 Multicast
8K
routes
VRF 16384
MACSEC N N N N N Y Y N N N N N N
ACL 120K 80K 80K 80K 40K 40K 40K 60K 40K 20K 20K 20K 20K
Y(V2R5
Y(V2R5 and Y(V2R5 and Y(V2R5 and
and
VXLAN L3 GW Y later later Y Y later Y Y Y Y Y Y
later
versions) versions) versions)
versions)
Number of
Broastcast 32K
Domains
Buffer 24G 16G 16G 64MB 8G 8G 8G 12G 8G 4G 1G 4G 4G
• Large capacity: High-density 40G switches: 32*40GE QSFP+ ports, industry’s highest
CE7800 All-40GE
switching capacity of 2.56 Tbps
core/aggregation
• High scalability: iStack for horizontal stacking, SVF for vertical expansion
/access switch • Flexible networking: BGP-EVPN-capable VXLAN gateway
High- • Large capacity: 24/48*GE RJ45 downlink ports, 40GE/10GE uplink ports
CE5800 performance GE • High scalability: iStack for horizontal stacking (up to 16 member switches), SVF for
ToR switch vertical expansion
• Flexible networking: BGP-EVPN-capable VXLAN gateway(CE 5880)
• High performance: 12 Gbit/s forwarding performance per core, 20% higher than industry average,
Virtual switch: CE1800V Open and and better user experience
compatible • Openness and compatibility: Standard southbound protocols and flexible compatibility with
multiple virtualization platforms
virtual switch
• Security protection: Integrated distributed firewall to implement security protection on a
per VM port basis
• Dual stack technology: dual stack forwarding capability and smooth evolution to IPv6
Forwarding
CloudEngine 6881-48S6CQ performance(Mpps) 940
Maximum number of
16
stacked switches
Forwarding
CloudEngine 6863-48S6CQ performance(Mpps) 940
Maximum number of
16
stacked switches
CE8860 replacement
Switching
6.4 Tbps
capacity
Forwarding
2030 Mpps
performance
Forwarding
4482 Mpps
performance
Maximum number of
16
stacked switches
Forwarding
3200Mpps
performance
Parameter CE7855-32CQ-EI
32*40GE QSFP+(Each port or be
Port mode
CE7855-32Q-EI split into four 10GE SFP+ ports.)
104 x 10GE SFP+ interfaces, 32 x 40GE QSFP28 interfaces Switching capacity 2560Gbps
Forwarding
1440Mpps
performance
Maximum number of
16
stacked switches
Parameter CE6880-24SQ2CQ-EI
Buffer capacity 4 GB
Switching
4.0 Tbps
capacity
Forwarding
2000 Mpps
performance
Two fan trays
Maximum number of
16
stacked switches
1+1 AC power redundancy
Maximum number of
16
1U devices in a stack
Switching capacity 2.16 Tbit/s
ToR switch with 10GE downlink and 100GE uplink, supporting VXLAN
and BGP EVPN
Hardware BFD
Microsegmentation
Telemetry and ERSPAN enhancement
Four fan trays (one fan module in1+1 power redundancy
each tray)
Maximum number of
16
stacked switches
Maximum number
of stacked 9
switches
Innovative 100GE/40GE twin-core fiber optical Scenario 1: 10GE to 100GE bandwidth upgrade
transceiver
Reuse 10GBase-SR fibers on 100G/40G transceivers:
100-300 m
transmission • Save fiber costs
distance
• Save O&M costs on new cables
100G/40G 100G/40G
3 ClickSwitches
Introduction to CloudEngine to add Title
Award of Excellent
In 2016, the CE8860 and Award of the Most Award of Excellent
Product Trusted by
CE6851 won the Best of Competitive Product Product in Big Data
CIO
Show Award at Interop.
Huawei's AI Fabric
Intelligent Lossless Data
Center Network Solution
Takes Home Interop Tokyo Preferred Brand of
China SDN
Best of Show Award Award of Annual Cloud Computing
SDN Best
Excellent Technology and Network
Practice Award
Solution
Cisco, 48.10%
Arista, 14.20%
H3C, 35.87%
In 2018, Huawei CloudEngine Data Center Switch’s sales In 2018,Huawei CloudEngine Data Center Switch’s global