You are on page 1of 2

PEREDO, JHUN ROCKFIELD L.

FEBRUARY 22, 2021


STTRDES1 -STEEL AND TIMBER DEISGN ENGR. SHACKILE ASUNCION

Quiz 2
1. An angular section 100 mm x 75 mm x 6.25 mm is riveted by a 19mm diameter rivets
arranged as indicated. Assume A36 steel and diameter of the hole is 3 mm greater than
rivet diameter.

A) Determine the capacity of the section based on yielding of gross area.


- T = Ag 0.60 Fy
- T = 168.75(6.25)(0.60)(248)
- T = 156937.5 N T = 156.94 kN
= 156.94 kN

B) Determine the capacity of the section based on tensile fracture of the net area.
Diameter of hole = 19 + 3
Diameter of hole = 22 mm

Considering section ABC:


Net width = 168.75 – 22
Net width = 146.75 mm

Considering section DEBC:


Net width =168.75 – 2(22) + S2
4g
Net width = 124.75 + (37.5) 2
4(100)
Net width =128.27 mm < 146.75 mm (use)
Net area An = 128.27(6.25)
An = 801.69 mm2
Capacity based on tensile fracture or net area:
T = An 0.50 Fu
T = 801.69(0.5)(400)
T = 160338 N
T = 160.34 kN

C) Determine the capacity of the section based on block shear failure.


T =Av 0.30 Fu
T =1559.375(0.3)(400) + 509.47(0.5)(400)
T =289019 N

Considering lines (FE + BG) as shear area and EB as tension area:

Shear area: (line FE and BG)


Av = [ 150−22−11+187.50−22−22−11] 6.25
PEREDO, JHUN ROCKFIELD L. FEBRUARY 22, 2021
STTRDES1 -STEEL AND TIMBER DEISGN ENGR. SHACKILE ASUNCION

Quiz 2

Tension area: (line EB)


At = 100−22+ (37.5)2 6.25
4(100)
At = 509.47 mm2
Considering FE as shear area and EBC as tension area.
Av = (150 – 22 – 11)(6.25)
Av = 731. 25 mm2
At = 100−22+ (37.5)2 6.25 + (37.5 – 11)(6.25)
4(100)
At = 675.10 mm2
T = Av 0.30 Fu + At (0.5) Fu
T = 731.25 (0.3) (400) + 675.10 (0.5) (400)
T = 222770 N
Use T = 222.77 kN