Professional Documents
Culture Documents
VLF truesinus® – A voltage shape for all methods and method combinations
VLF truesinus® is the only voltage shape that enables both the reliable voltage tests as well as precise dissipation factor
measurements and partial discharge testing. Unlike other voltage shapes, the VLF truesinus® voltage is load-independent,
symmetrical and continuous. This is a prerequisite for high precision as well as reproducibility and comparability of
measurement results.
PD testing ▪ Diagnostics of local weak points and their location frida & PD-TaD 62
Simultaneous dissi- ▪ Combination of statements of a dissipation factor measurement and PD testing frida TD & PD-TaD 62
pation factor and PD ▪ Shorter test duration with simultaneous dissipation factor measurement and PD testing
measurement
▪ Better detection of hidden faults (e.g. moist joints) through conditioning of weak points and
simultaneous monitoring of TD values and PD activities
MWT with dissipation ▪ Evaluation of the dielectric condition of the insulation, indication of PD frida TD & PD-TaD 62
factor measurement ▪ Intelligent withstand voltage test
▪ Shorter test duration for cables in good condition
VLF cable testing with ▪ Localisation of faults in the cable insulation frida & PD-TaD 62
parallel PD testing ▪ Intelligent withstand voltage test
Full MWT (VLF cable ▪ Evaluation of the dielectric condition of the insulation, indication of PD frida TD & PD-TaD 62
testing with parallel ▪ Localisation of faults in the cable insulation
dissipation factor
and partial discharge ▪ Intelligent withstand voltage test with shorter test duration for cables in good condition
measurement) ▪ Shorter test duration with simultaneous dissipation factor measurement and PD testing
▪ Better detection of hidden faults (e.g. moist joints) through conditioning of weak points and
simultaneous monitoring of TD values and PD activities
Page 2/5 Data sheet: BAUR GmbH ·826-095-8 · 09.2020 · Subject to modifications
Technical data
Load range (VLF testing) 1 nF – 8 µF Degree of protection IP54 (in closed state)
Data sheet: BAUR GmbH · 826-095-8 · 09.2020 · Subject to modifications Page 3/5
frida standard delivery frida TD standard delivery
▪ BAUR frida VLF tester, incl. ▪ BAUR frida TD VLF tester and diagnostics device, incl.
– HV connection cable, 5 m (fix mounted) – HV connection cable, 5 m (fix mounted)
– GDR 40-136 discharge and earth rod – GDR 40-136 discharge and earth rod
– Earth cable, 5 m, with earth terminal – Earth cable, 5 m, with earth terminal
– Jumper plug for external emergency off unit – Jumper plug for external emergency off unit
– Diagnostic reporter on USB drive – Diagnostic reporter on USB drive
– Mains supply cord, 2.5 m – BAUR tan delta kit
– User manual – Mains supply cord, 2.5 m
– Pocket guide – User manual
– Additional manual for dissipation factor measurement
– Pocket guide
▪ E xternal emergency off unit with signal lamps, 25 m or 50 m cable length ▪ VSE connection kit (for the detection and compensation of leakage
▪ GDR 40-136 discharge and earth rod currents)
▪ PD-TaD 62 portable PD diagnostics system ▪ E xternal emergency off unit with signal lamps, 25 m or 50 m cable length
▪ Remote control via BAUR Software: ▪ GDR 40-136 discharge and earth rod
– Laptop with pre-installed Windows operating system and BAUR Soft- ▪ PD-TaD 62 portable PD diagnostics system
ware 4, incl. carrying bag ▪ Remote control via BAUR Software:
– USB cable 2.0, 3 m – Laptop with pre-installed Windows operating system and BAUR Soft-
ware 4, incl. carrying bag
Optional software functions*
– USB cable 2.0, 3 m
– GIS interface
– BAUR GeoBaseMap (countries available on request) Optional software functions*
– Office installation (BAUR Software 4 for office PC) – GIS interface
– Cable testing – BAUR GeoBaseMap (countries available on request)
– PD measurement (partial discharge measurement) – Office installation (BAUR Software 4 for office PC)
– Cable testing
– PD measurement (partial discharge measurement)
– TD measurement (dissipation factor measurement)
– TD || PD measurement (parallel dissipation factor and partial dis-
charge measurement)
Information on individual functions and the required system configuration can be obtained from your BAUR representative
(www.baur.eu/en/baur-worldwide).
Page 4/5 Data sheet: BAUR GmbH ·826-095-8 · 09.2020 · Subject to modifications
Contact:
BAUR GmbH (Headoffice Österreich) BAUR France 奥地利保尔公司上海代表处 BAUR Representative Office Hong Kong
T +43 (0)5522 4941-0 T +33 (0)9 800 10 300 电话 +86 (0)21 6133 1877 T +852 2780 9029
F +43 (0)5522 4941-3 F +33 (0) 172 718 485 传真 +86 (0)21 6133 1886 F +852 2780 9039
headoffice@baur.at info@baur-france.at shanghaioffice@baur.at office.hongkong@baur.at
www.baur.eu www.baur-france.at/fr www.baur.eu/cn www.baur.eu
BAUR Prüf- und Messtechnik GmbH Baur do Brasil Ltda. BAUR Test Equipment Ltd. (UK) BAUR representatives:
T +49 (0)2181 2979 0 T +55 11 297 25 272 T +44 (0)20 8661 957 www.baur.eu/en/baur-worldwide
F +49 (0)2181 2979 10 atendimento@baurdobrasil.com.br sales@baurtest.com
vertrieb@baur-germany.de www.baurdobrasil.com.br www.baurtest.com
www.baur.eu
Data sheet: BAUR GmbH · 826-095-8 · 09.2020 · Subject to modifications Page 5/5