In responsive to the growing demand for a Composite Metal Deck flooring system in India, FAISAL ROOFING have developed a
range of new profile unique and a true steel concrete composite DECK for the Indian construction market. Super Deck with
special in built shear connectors of bonding of concrete with DECK sheets.
Brief
SUPER DECK is a cold formed corrugated steel sheet supported by steel joists or beams. It is used to support concrete or
insulating membrane of a roof. It has been designed and developed to provide a structurally efficient product for use in roof and
floor systems.
SUPER DECK is also known as Composite deck, it has embossments in the vertical ribs that bond with the concrete slab to
develop a composite floor system. Composite deck acts as a form during the concrete pour. SUPER DECK is a long-span
composite floor system that blends steel's speed and versatility with concrete's performance and durability.
SHEAR STUD
Composite beams are typically hot rolled steel sections that act compositely with a
concrete slab. Shear studs are required to transfer force between the steel section
and the concrete slab. The studs are welded to the beam, normally through the Deck
sheet. This enables the concrete slab to act like a large top flange to the composite
beam when the concrete has hardened and creates a stronger section to support the
loadings applied to the finished slab.
25mm dimension is from mid - point of web of nib
When installing shear studs, the length after weld should extend at least 35 mm
above the top of the main rib of the Deck profile.
Unit/Weight Section
Thickness Moment of
Sr. No. Kg/m^2 Modulus
mm Inertia cm^4
cm^3
1 0.8 7.85 83.71 28.14
2 0.9 8.83 94.06 31.63
3 1 9.81 104.38 35.11
4 1.2 11.78 124.91 42.05
5 1.35 13.25 140.23 47.23
6 1.5 14.72 155.46 52.39
Notes
1. The properties given are for one meter width of the Profile.
2. Limiting deflection is taken as span L/180 during green concrete conditions and L/250 during composite stage.
3. Allowable loads are applicable for sheets spanning over a minimum of four supports and for permanent shuttering only.
4. Allowable loads may be multiplied by a factor of 0.80 for sheets spanning over 2 or 3 supports.
5. Shear Connectors / Ribs are necessary.